Monessen Hearth WDV500 manual Venting Installation Information, Installation precautions

Page 10

WDV Series Gas Fireplace

Venting INSTALLATION INFORMATION

 

 

WARNING

Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life.

installation precautions

Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. The approved 5 x 8 venting components are Simpson Duravent and Selkirk products listed on Page 41. UL1777 flexible venting is also approved for use on these models. Before installing vent kit, the installer must read this fireplace manual and vent kit instructions.

Only a qualified installer/service person should install venting system. The installer must follow these safety rules:

Wear gloves and safety glasses for protection.

Use extreme caution when using lad- ders or when on rooftops.

Be aware of electrical wiring locations in walls and ceilings.

The following actions will void the warranty on your venting system:

Installation of any damaged venting component.

A minimum of 1" clearance to all sides is required along horizontal and vertical length

12" Vertical Rise

Required Before

Horizontal Run

 

A minimum 1"

 

clearance to

1”

combustibles

permitted all

 

 

around flue at

 

outside wall

 

 

50”

Min. Floor

to Center of Vent Pipe

Unauthorized modification of the vent- ing system.

Installation of any component part not manufactured or approved by MHSC.

Installation other than permitted by these instruc- tions.

 

NOTICE

Failure to follow these instructions will

 

 

 

 

void the warranty.

 

 

 

FP2424

Figure 7 -

Combustible Clearances for Vent Pipe

WARNING

This fireplace must be vented to the outside. The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance must use a separate vent system. Do not use common vent systems.

WARNING

Horizontal and vertical sections of this vent system require a minimum of 1" clearance to combustibles on all sides, top and bottom.

10

78D0011

Image 10
Contents WDV Wideview Direct Vent Gas Fireplace Signature Command System Operating InstructionsInstaller Important Safety InformationOwner Gas wells. This gas is commonly known Code ApprovalNever connect unit to private non-utility As wellhead gasProduct features and code approval High ElevationsFireplace & Framing Dimensions Fireplace and Framing DimensionsFireplace Location PRE-INSTALLATION InformationCold Climate Insulation Mantel clearances ClearancesClearances to combustibles Side ViewFinishing Material Never install combustible materials overSecure Fireplace to floor or framing Front face of fireplaceVoid the warranty Venting Installation InformationInstallation precautions Failure to follow these instructions willInstalling a vent system in an outside chase Vent installationInstallation planning For horizontal terminationFor horizontal termination Inside Corner Detail Venting installationAir Supply Inlet Area Where Terminals Not Permitted Minimum distancesVenting installation How To Use The Vent GraphVERTICAL/Horizontal termination configurations Maximum Three 3 90 Elbows Per InstallationBelow Grade Installations WallClearance of at least 4 must be Vertical through-the-roof applicationsDo not back fill around snorkel Maintained between the snorkelVenting installation Installation for vertical termination Flat ceiling installationTermination Heights for Vents Above Flat or Sloped Roofs Flex Vent Installation Flex Vent Installation Installation items needed Fireplace installationInstalling gas piping to fireplace location Check gas typeNatural Gas Propane/LPDo not use open flame to check for gas leaks Electrical WiringImproper and dangerous operation Command Center Wall Installation Caut NIO AW RNI GNWiring to junction box Signature command Optional fan blower systemOptional Fan/Blower System Blotbldvsc Light Installation Glass removal & light placementGlass Frame Removal Stone & Glass Placement Stone & glass placementGlass only Placement Signature command Operating Instructions What to do if YOU Smell GASSwitch Box OPERATing InstructionsFeatures Battery InstallationKey Combinations for System Settings Signature Command System Operation InstructionsSystem CONFIGURATION/SETUP Function Operation Default SettingSelf Diagnostics Chart Command Center FUNCTIONS/OPERATIONCommand Center Operations Fault LeD IndicationRemote Control Operation Remote Transmitter OperationsSpeed Blower Control Optional Flame Height Setting for Thermostatic ModeLevel Light Brightness Control ON/OFF AUX Control Optional Remote Control OperationLow Battery Detection Child-Proof ProtectionCleaning and maintenance Burner, Pilot and Control CompartmentGlass Door Vent SysteMStones Troubleshooting Signature Command SystemAccessories / Field Installed Options Replacement PartsFirebox components and accessories Description Qty WDV500Replacement Parts Replacement Parts LP to Natural GasVent components Current Old Simpson Duravent Vent Components for 5 XOr Mhsc Selkirk Box Description Stones WDV Series Gas Fireplace Massachusetts Manufacturer RequirementsBasic Warranty Lifetime WarrantyFive Year Warranty If Warranty Service is NeededMhsc Model

WDV500 specifications

The Monessen Hearth WDV500 is a stylish and efficient direct vent gas fireplace designed to enhance any living space. This fireplace combines modern aesthetics with advanced technology to create a cozy atmosphere while ensuring optimal performance. With its sleek design and versatile installation options, it caters to various home styles, making it an ideal choice for homeowners looking to elevate their ambiance.

One of the standout features of the WDV500 is its direct vent system, which allows for safe and efficient operation. This system utilizes outside air for combustion, ensuring that indoor air quality is maintained. By drawing air from the outside and venting exhaust gases directly outside, the WDV500 minimizes heat loss and maximizes energy efficiency. This makes it an environmentally friendly option, aligning with contemporary sustainability practices.

The Monessen Hearth WDV500 is equipped with a variety of innovative technologies aimed at providing users with ease of use and improved functionality. The adjustable flame control allows homeowners to customize the intensity of the fire to suit their mood or occasion. Additionally, the WDV500 features a high-efficiency burner that generates an impressive heat output, ensuring that rooms are kept warm and inviting even during the coldest months.

In terms of design, the WDV500 offers multiple finish options and accessory features, allowing it to seamlessly blend into any decor. A stunning selection of logs, crystals, or stones enhances the visual appeal of the fireplace, giving it a contemporary touch that complements traditional or modern interiors alike.

Safety is a priority with the Monessen Hearth WDV500, which includes an automatic shut-off feature that engages if the unit experiences overheating, ensuring peace of mind for users. The fireplace's straightforward installation process further emphasizes its user-friendly design, suitable for both new builds and retrofitting into existing spaces.

Overall, the Monessen Hearth WDV500 represents a harmonious blend of technology, safety, and style. Whether for relaxation on chilly evenings or for entertaining guests, this versatile fireplace provides warmth and elegance, making it a perfect addition to any home. Its efficient performance, customizable features, and aesthetic appeal make the WDV500 a popular choice among discerning homeowners.