Monessen Hearth WDV500 manual Electrical Wiring, Do not use open flame to check for gas leaks

Page 23

SIGNATURE COMMAND - CHECK GAS PRESSURE and ELECTRICAL INSTALLATIONWDV Series Gas Fireplace

1.Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately.

2.To ease installation, a 24" (610 mm) flex line with manual shut-off valve has been provided with on this appliance. Install and attach 1/2" gas line onto shut-off valve.

3.After completing gas line connection, purge air from gas line and test all gas joints from the gas meter to the fireplace for leaks. Use a solution of 50/50 water and soap solution or a gas sniffer.

4.To check gas pressures at valve, turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point. Turn unit to high. Fig- ure 31 After taking pressure reading, be sure and turn captured screw clockwise firmly to reseal. Do not over torque. Check test points for gas leaks.

Pressure Inlet

 

FP1909a

Pressure Outlet

Pilot Adjust-

ment Screw

 

Figure 31 -

Signature Command Valve

WARNING

Do not use open flame to check for gas leaks.

Electrical Wiring

This fireplace will work without any electrical supply. Electricity is only needed to operate blower.

NOTE: If installed in mobile home, fireplace must be bolted securely to floor.

WARNING

Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service. All wiring shall be in compliance with all local, city, and state codes. The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI/ NFPA 70 (latest edition) and Canadian Electrical Code, CSA C22.1.

 

CAUTION

Label all wires before disconnecting when

 

servicing controls. Wiring errors can cause

 

 

 

 

improper and dangerous operation.

 

 

 

Verify proper operation after servicing.

78D0011

23

Image 23
Contents WDV Wideview Direct Vent Gas Fireplace Operating Instructions Signature Command SystemOwner Important Safety InformationInstaller As wellhead gas Code ApprovalNever connect unit to private non-utility Gas wells. This gas is commonly knownHigh Elevations Product features and code approvalFireplace and Framing Dimensions Fireplace & Framing DimensionsCold Climate Insulation PRE-INSTALLATION InformationFireplace Location Side View ClearancesClearances to combustibles Mantel clearancesFront face of fireplace Never install combustible materials overSecure Fireplace to floor or framing Finishing MaterialFailure to follow these instructions will Venting Installation InformationInstallation precautions Void the warrantyFor horizontal termination Vent installationInstallation planning Installing a vent system in an outside chaseMinimum distances Venting installationAir Supply Inlet Area Where Terminals Not Permitted For horizontal termination Inside Corner DetailHow To Use The Vent Graph Venting installationMaximum Three 3 90 Elbows Per Installation VERTICAL/Horizontal termination configurationsWall Below Grade InstallationsMaintained between the snorkel Vertical through-the-roof applicationsDo not back fill around snorkel Clearance of at least 4 must beFlat ceiling installation Venting installation Installation for vertical terminationTermination Heights for Vents Above Flat or Sloped Roofs Flex Vent Installation Flex Vent Installation Check gas type Fireplace installationInstalling gas piping to fireplace location Installation items neededPropane/LP Natural GasImproper and dangerous operation Electrical WiringDo not use open flame to check for gas leaks Caut NIO AW RNI GN Command Center Wall InstallationOptional Fan/Blower System Blotbldvsc Signature command Optional fan blower systemWiring to junction box Glass Frame Removal Glass removal & light placementLight Installation Glass only Placement Stone & glass placementStone & Glass Placement What to do if YOU Smell GAS Signature command Operating InstructionsOPERATing Instructions Switch BoxBattery Installation FeaturesFunction Operation Default Setting Signature Command System Operation InstructionsSystem CONFIGURATION/SETUP Key Combinations for System SettingsFault LeD Indication Command Center FUNCTIONS/OPERATIONCommand Center Operations Self Diagnostics ChartRemote Transmitter Operations Remote Control OperationLevel Light Brightness Control Flame Height Setting for Thermostatic ModeSpeed Blower Control Optional Child-Proof Protection Remote Control OperationLow Battery Detection ON/OFF AUX Control OptionalBurner, Pilot and Control Compartment Cleaning and maintenanceStones Vent SysteMGlass Door Signature Command System TroubleshootingDescription Qty WDV500 Replacement PartsFirebox components and accessories Accessories / Field Installed OptionsReplacement Parts LP to Natural Gas Replacement PartsVent components Or Mhsc Selkirk Box Description Vent Components for 5 XCurrent Old Simpson Duravent Stones WDV Series Gas Fireplace Manufacturer Requirements MassachusettsIf Warranty Service is Needed Lifetime WarrantyFive Year Warranty Basic WarrantyModel Mhsc

WDV500 specifications

The Monessen Hearth WDV500 is a stylish and efficient direct vent gas fireplace designed to enhance any living space. This fireplace combines modern aesthetics with advanced technology to create a cozy atmosphere while ensuring optimal performance. With its sleek design and versatile installation options, it caters to various home styles, making it an ideal choice for homeowners looking to elevate their ambiance.

One of the standout features of the WDV500 is its direct vent system, which allows for safe and efficient operation. This system utilizes outside air for combustion, ensuring that indoor air quality is maintained. By drawing air from the outside and venting exhaust gases directly outside, the WDV500 minimizes heat loss and maximizes energy efficiency. This makes it an environmentally friendly option, aligning with contemporary sustainability practices.

The Monessen Hearth WDV500 is equipped with a variety of innovative technologies aimed at providing users with ease of use and improved functionality. The adjustable flame control allows homeowners to customize the intensity of the fire to suit their mood or occasion. Additionally, the WDV500 features a high-efficiency burner that generates an impressive heat output, ensuring that rooms are kept warm and inviting even during the coldest months.

In terms of design, the WDV500 offers multiple finish options and accessory features, allowing it to seamlessly blend into any decor. A stunning selection of logs, crystals, or stones enhances the visual appeal of the fireplace, giving it a contemporary touch that complements traditional or modern interiors alike.

Safety is a priority with the Monessen Hearth WDV500, which includes an automatic shut-off feature that engages if the unit experiences overheating, ensuring peace of mind for users. The fireplace's straightforward installation process further emphasizes its user-friendly design, suitable for both new builds and retrofitting into existing spaces.

Overall, the Monessen Hearth WDV500 represents a harmonious blend of technology, safety, and style. Whether for relaxation on chilly evenings or for entertaining guests, this versatile fireplace provides warmth and elegance, making it a perfect addition to any home. Its efficient performance, customizable features, and aesthetic appeal make the WDV500 a popular choice among discerning homeowners.