Monessen Hearth WDV500 Venting installation, For horizontal termination Inside Corner Detail

Page 12

WDV Series Gas Fireplace

 

 

 

 

 

 

 

 

venting installation

For horizontal termination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inside Corner Detail

 

 

 

 

 

 

 

 

 

V

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

A

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

C

 

B

 

B

 

 

 

 

G

 

B

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

I

 

 

 

L

V

Fixed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Closed

V

Opera-

Fixed

V

 

 

 

 

 

F

 

Operable

ble

Closed

 

 

 

 

 

 

V B

 

 

V

A

 

 

 

M

 

 

 

 

 

B

 

 

V A

A

 

 

 

 

A

 

J

 

 

 

K

 

 

 

 

 

 

 

 

 

 

V

 

A

 

 

 

 

 

 

 

 

Figure 8 -

Vent Terminal

Air Supply Inlet

 

Area Where Terminals Not Permitted

 

Horizontal Vent Termination Location

minimum distances

A = Clearance above the grade, a veranda, porch, deck, or balcony [*12" (305 mm) minimum]. B = Clearance to window or door that may be opened [*12" (305 mm) minimum].

C = Clearance to permanently closed window [*minimum 12" (305 mm) recommended to prevent condensation on window]

D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of two (2) feet (610 mm) from the centerline of the terminal [18" (457 mm) minimum].

E = Clearance to unventilated soffits [12" (305 mm) minimum]. Clearance to vinyl soffit [30" (762 mm)]. F = Clearance to an outside corner. Figure 9

G = Clearance to an inside corner. Figure 9

H = *Not to be installed above a gas meter/regulator assembly within three (3) feet (914 mm) horizontally from the centerline of the regulator.

I = Clearance to service regulator vent outlet [*3' (914 mm) minimum].

J = Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance [*12" (305 mm) minimum].

K = Clearance to a mechanical air supply inlet [*6' (1829 mm) minimum].

L = Clearance above a paved sidewalk or paved driveway located on public property [**7' (2133 mm) minimum].

M = Clearance under veranda, porch, deck, or balcony [For Canada 12" (305 mm) minimum***] Figure 9

*As specified in CSA B149 Installation Codes. Note: Local codes or regulations may require different clearances.

**A vent must not terminate directly above a sidewalk or paved driveway, which is located between two single- family dwellings and serves both dwellings.

***Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

WARNING

Always maintain minimum clearances around vent systems. The minimum clearances to combustibles for horizontal and vertical vent pipe are 1" at the top, sides and bottom of the vent system. Do not pack the open air spaces with insulation or other materials. This could cause high temperatures and may

present a fire hazard.

12

78D0011

Image 12
Contents WDV Wideview Direct Vent Gas Fireplace Signature Command System Operating InstructionsImportant Safety Information InstallerOwner Code Approval Never connect unit to private non-utilityGas wells. This gas is commonly known As wellhead gasProduct features and code approval High ElevationsFireplace & Framing Dimensions Fireplace and Framing DimensionsPRE-INSTALLATION Information Fireplace LocationCold Climate Insulation Clearances Clearances to combustiblesMantel clearances Side ViewNever install combustible materials over Secure Fireplace to floor or framingFinishing Material Front face of fireplaceVenting Installation Information Installation precautionsVoid the warranty Failure to follow these instructions willVent installation Installation planningInstalling a vent system in an outside chase For horizontal terminationVenting installation Air Supply Inlet Area Where Terminals Not PermittedFor horizontal termination Inside Corner Detail Minimum distancesVenting installation How To Use The Vent GraphVERTICAL/Horizontal termination configurations Maximum Three 3 90 Elbows Per InstallationBelow Grade Installations WallVertical through-the-roof applications Do not back fill around snorkelClearance of at least 4 must be Maintained between the snorkelVenting installation Installation for vertical termination Flat ceiling installationTermination Heights for Vents Above Flat or Sloped Roofs Flex Vent Installation Flex Vent Installation Fireplace installation Installing gas piping to fireplace locationInstallation items needed Check gas typeNatural Gas Propane/LPElectrical Wiring Do not use open flame to check for gas leaksImproper and dangerous operation Command Center Wall Installation Caut NIO AW RNI GNSignature command Optional fan blower system Wiring to junction boxOptional Fan/Blower System Blotbldvsc Glass removal & light placement Light InstallationGlass Frame Removal Stone & glass placement Stone & Glass PlacementGlass only Placement Signature command Operating Instructions What to do if YOU Smell GASSwitch Box OPERATing InstructionsFeatures Battery InstallationSignature Command System Operation Instructions System CONFIGURATION/SETUPKey Combinations for System Settings Function Operation Default SettingCommand Center FUNCTIONS/OPERATION Command Center OperationsSelf Diagnostics Chart Fault LeD IndicationRemote Control Operation Remote Transmitter OperationsFlame Height Setting for Thermostatic Mode Speed Blower Control OptionalLevel Light Brightness Control Remote Control Operation Low Battery DetectionON/OFF AUX Control Optional Child-Proof ProtectionCleaning and maintenance Burner, Pilot and Control CompartmentVent SysteM Glass DoorStones Troubleshooting Signature Command SystemReplacement Parts Firebox components and accessoriesAccessories / Field Installed Options Description Qty WDV500Replacement Parts Replacement Parts LP to Natural GasVent components Vent Components for 5 X Current Old Simpson DuraventOr Mhsc Selkirk Box Description Stones WDV Series Gas Fireplace Massachusetts Manufacturer RequirementsLifetime Warranty Five Year WarrantyBasic Warranty If Warranty Service is NeededMhsc Model

WDV500 specifications

The Monessen Hearth WDV500 is a stylish and efficient direct vent gas fireplace designed to enhance any living space. This fireplace combines modern aesthetics with advanced technology to create a cozy atmosphere while ensuring optimal performance. With its sleek design and versatile installation options, it caters to various home styles, making it an ideal choice for homeowners looking to elevate their ambiance.

One of the standout features of the WDV500 is its direct vent system, which allows for safe and efficient operation. This system utilizes outside air for combustion, ensuring that indoor air quality is maintained. By drawing air from the outside and venting exhaust gases directly outside, the WDV500 minimizes heat loss and maximizes energy efficiency. This makes it an environmentally friendly option, aligning with contemporary sustainability practices.

The Monessen Hearth WDV500 is equipped with a variety of innovative technologies aimed at providing users with ease of use and improved functionality. The adjustable flame control allows homeowners to customize the intensity of the fire to suit their mood or occasion. Additionally, the WDV500 features a high-efficiency burner that generates an impressive heat output, ensuring that rooms are kept warm and inviting even during the coldest months.

In terms of design, the WDV500 offers multiple finish options and accessory features, allowing it to seamlessly blend into any decor. A stunning selection of logs, crystals, or stones enhances the visual appeal of the fireplace, giving it a contemporary touch that complements traditional or modern interiors alike.

Safety is a priority with the Monessen Hearth WDV500, which includes an automatic shut-off feature that engages if the unit experiences overheating, ensuring peace of mind for users. The fireplace's straightforward installation process further emphasizes its user-friendly design, suitable for both new builds and retrofitting into existing spaces.

Overall, the Monessen Hearth WDV500 represents a harmonious blend of technology, safety, and style. Whether for relaxation on chilly evenings or for entertaining guests, this versatile fireplace provides warmth and elegance, making it a perfect addition to any home. Its efficient performance, customizable features, and aesthetic appeal make the WDV500 a popular choice among discerning homeowners.