Monessen Hearth WDV500 manual Features, Battery Installation

Page 30

WDV Series Gas Fireplace

SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS

FEATURES

 

 

 

Command Center

 

RF Receiver

To Thermopile

 

 

Easy Access Function Operation and System Configura-

ON/OFF

To Sensor

 

 

 

tion

 

 

To Sparker

Operation Confirmation/Fault Diagnostic Indications (LED/

NG/LP

 

Buzzer)

 

Conversion

 

ON/OFF/HI/Low Operation

 

 

 

 

 

Control Board

Electronic Ignition

Pilot Lockout safety feature

Electric Power Regeneration from Thermopile to save bat-

tery

6-hour Automatic Shut Down Option

Convenient NG/LP Gas Type Conversion

Standing Pilot/Intermittent pilot Conversion

Previous settings Restoration Ability

Uninterrupted Operation During Power Outage (Automatic

Control

Board

Command Center

To Command

Center

To Stepper Motor

To Valve

Battery Door

AC Module

 

Battery Backup)

ON/OFF RF Remote Receiver

Optional Transmitter Learn Capability

AC Module

Easy Snap-on Design

Embedded Compact 120 V AC Adapter with Auto Battery Back up Feature

Remote Controlled Blower, Lighting, and Auxiliary AC Outputs

Transmitter

RFSC

Three Flame Height Settings

X

Low battery Indication for Transmitter

X

Child Proof Lock-out

X

LCD Backlight

X

Security Codes

X

Thermostatic Control Mode

X

Three Brightness Settings for Lights

X

Three Speed Control for Blower

X

On/Off AUX Control

X

Programmable Timer to turn blower on and off

X

Master Switch

ON

LED

OFF

Figure 38 - Signature Command System Components

BATTERY INSTALLATION

The Command Center uses four (4) "AA" batteries.

To Install Batteries:

1.Press down the battery door tabs and pull out to remove battery door.

2.Install the batteries as indicated on Command Center.

3.Close battery door by snapping in place.

4.When the four (4) batteries are installed the system is ready for use.

5.The batteries should be replaced when the LED indicates low battery.

30

78D0011

Image 30
Contents WDV Wideview Direct Vent Gas Fireplace Signature Command System Operating InstructionsImportant Safety Information InstallerOwner Gas wells. This gas is commonly known Code ApprovalNever connect unit to private non-utility As wellhead gasProduct features and code approval High ElevationsFireplace & Framing Dimensions Fireplace and Framing DimensionsPRE-INSTALLATION Information Fireplace LocationCold Climate Insulation Mantel clearances ClearancesClearances to combustibles Side ViewFinishing Material Never install combustible materials overSecure Fireplace to floor or framing Front face of fireplaceVoid the warranty Venting Installation InformationInstallation precautions Failure to follow these instructions willInstalling a vent system in an outside chase Vent installationInstallation planning For horizontal terminationFor horizontal termination Inside Corner Detail Venting installationAir Supply Inlet Area Where Terminals Not Permitted Minimum distancesVenting installation How To Use The Vent GraphVERTICAL/Horizontal termination configurations Maximum Three 3 90 Elbows Per InstallationBelow Grade Installations WallClearance of at least 4 must be Vertical through-the-roof applicationsDo not back fill around snorkel Maintained between the snorkelVenting installation Installation for vertical termination Flat ceiling installationTermination Heights for Vents Above Flat or Sloped Roofs Flex Vent Installation Flex Vent Installation Installation items needed Fireplace installationInstalling gas piping to fireplace location Check gas typeNatural Gas Propane/LPElectrical Wiring Do not use open flame to check for gas leaksImproper and dangerous operation Command Center Wall Installation Caut NIO AW RNI GNSignature command Optional fan blower system Wiring to junction boxOptional Fan/Blower System Blotbldvsc Glass removal & light placement Light InstallationGlass Frame Removal Stone & glass placement Stone & Glass PlacementGlass only Placement Signature command Operating Instructions What to do if YOU Smell GASSwitch Box OPERATing InstructionsFeatures Battery InstallationKey Combinations for System Settings Signature Command System Operation InstructionsSystem CONFIGURATION/SETUP Function Operation Default SettingSelf Diagnostics Chart Command Center FUNCTIONS/OPERATIONCommand Center Operations Fault LeD IndicationRemote Control Operation Remote Transmitter OperationsFlame Height Setting for Thermostatic Mode Speed Blower Control OptionalLevel Light Brightness Control ON/OFF AUX Control Optional Remote Control OperationLow Battery Detection Child-Proof ProtectionCleaning and maintenance Burner, Pilot and Control CompartmentVent SysteM Glass DoorStones Troubleshooting Signature Command SystemAccessories / Field Installed Options Replacement PartsFirebox components and accessories Description Qty WDV500Replacement Parts Replacement Parts LP to Natural GasVent components Vent Components for 5 X Current Old Simpson DuraventOr Mhsc Selkirk Box Description Stones WDV Series Gas Fireplace Massachusetts Manufacturer RequirementsBasic Warranty Lifetime WarrantyFive Year Warranty If Warranty Service is NeededMhsc Model

WDV500 specifications

The Monessen Hearth WDV500 is a stylish and efficient direct vent gas fireplace designed to enhance any living space. This fireplace combines modern aesthetics with advanced technology to create a cozy atmosphere while ensuring optimal performance. With its sleek design and versatile installation options, it caters to various home styles, making it an ideal choice for homeowners looking to elevate their ambiance.

One of the standout features of the WDV500 is its direct vent system, which allows for safe and efficient operation. This system utilizes outside air for combustion, ensuring that indoor air quality is maintained. By drawing air from the outside and venting exhaust gases directly outside, the WDV500 minimizes heat loss and maximizes energy efficiency. This makes it an environmentally friendly option, aligning with contemporary sustainability practices.

The Monessen Hearth WDV500 is equipped with a variety of innovative technologies aimed at providing users with ease of use and improved functionality. The adjustable flame control allows homeowners to customize the intensity of the fire to suit their mood or occasion. Additionally, the WDV500 features a high-efficiency burner that generates an impressive heat output, ensuring that rooms are kept warm and inviting even during the coldest months.

In terms of design, the WDV500 offers multiple finish options and accessory features, allowing it to seamlessly blend into any decor. A stunning selection of logs, crystals, or stones enhances the visual appeal of the fireplace, giving it a contemporary touch that complements traditional or modern interiors alike.

Safety is a priority with the Monessen Hearth WDV500, which includes an automatic shut-off feature that engages if the unit experiences overheating, ensuring peace of mind for users. The fireplace's straightforward installation process further emphasizes its user-friendly design, suitable for both new builds and retrofitting into existing spaces.

Overall, the Monessen Hearth WDV500 represents a harmonious blend of technology, safety, and style. Whether for relaxation on chilly evenings or for entertaining guests, this versatile fireplace provides warmth and elegance, making it a perfect addition to any home. Its efficient performance, customizable features, and aesthetic appeal make the WDV500 a popular choice among discerning homeowners.