Monessen Hearth WDV500 manual Signature command Optional fan blower system, Wiring to junction box

Page 25

signature command - Optional fan blower system

WDV Series Gas Fireplace

 

 

A/C Wiring to junction box

important: Always check local building codes. This installation must comply with local regulations as well as the National Electric Code.

WIRING

1.Before installing the blower, wire the receptacle into an electrical circuit. This should be done before framing the fireplace. Wire with minimum 60° C wire in accordance with prevailing codes.

2.Remove the external junction box cover by removing the screw from the right side of the outside firebox wall. Junction box was installed at the factory.

3.The junction box cover has a factory installed “romex” style strain relief connector. After connecting the wires, route the wire leads through this connector. Refer to the wiring diagram in Figure 33.

 

 

 

 

 

 

 

 

 

 

120V AC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60Hz

 

 

 

 

 

 

 

 

 

 

Factory Supplied

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Not Supplied

 

Junction Box

 

 

Figure 33 -

 

 

Junction Box Wiring Diagram

 

 

RNGNI

Before installing the blower, turn off the fireplace and

allow to cool. Only a qualified service person should

service and repair the fireplace. A qualified service

 

AW

person should connect and disconnect the fireplace

to gas supply. Follow all local codes.

 

 

 

 

 

 

 

 

 

 

 

 

Optional Fan/Blower System (BLOTBLDVSC)

Black

 

To Junction Box

 

AC Module

 

 

 

 

In Fireplace

 

 

Blower

 

Light {

 

Right

 

White

 

White

 

Black

 

 

 

Black

Black

AUX {

Black

 

 

White

Blower

 

 

Green

 

 

 

Left

 

 

Connector

 

 

 

Pin To Control Box

Figure 34 -

 

Control Box

 

 

Blower Wiring Diagram

 

 

 

 

FP1915

AW RNI GN

Electrical Grounding Instructions: This appli- ance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle.

78D0011

25

Image 25
Contents WDV Wideview Direct Vent Gas Fireplace Operating Instructions Signature Command SystemInstaller Important Safety InformationOwner Never connect unit to private non-utility Code ApprovalGas wells. This gas is commonly known As wellhead gasHigh Elevations Product features and code approvalFireplace and Framing Dimensions Fireplace & Framing DimensionsFireplace Location PRE-INSTALLATION InformationCold Climate Insulation Clearances to combustibles ClearancesMantel clearances Side ViewSecure Fireplace to floor or framing Never install combustible materials overFinishing Material Front face of fireplaceInstallation precautions Venting Installation InformationVoid the warranty Failure to follow these instructions willInstallation planning Vent installationInstalling a vent system in an outside chase For horizontal terminationAir Supply Inlet Area Where Terminals Not Permitted Venting installationFor horizontal termination Inside Corner Detail Minimum distancesHow To Use The Vent Graph Venting installationMaximum Three 3 90 Elbows Per Installation VERTICAL/Horizontal termination configurationsWall Below Grade InstallationsDo not back fill around snorkel Vertical through-the-roof applicationsClearance of at least 4 must be Maintained between the snorkelFlat ceiling installation Venting installation Installation for vertical terminationTermination Heights for Vents Above Flat or Sloped Roofs Flex Vent Installation Flex Vent Installation Installing gas piping to fireplace location Fireplace installationInstallation items needed Check gas typePropane/LP Natural GasDo not use open flame to check for gas leaks Electrical WiringImproper and dangerous operation Caut NIO AW RNI GN Command Center Wall InstallationWiring to junction box Signature command Optional fan blower systemOptional Fan/Blower System Blotbldvsc Light Installation Glass removal & light placementGlass Frame Removal Stone & Glass Placement Stone & glass placementGlass only Placement What to do if YOU Smell GAS Signature command Operating InstructionsOPERATing Instructions Switch BoxBattery Installation FeaturesSystem CONFIGURATION/SETUP Signature Command System Operation InstructionsKey Combinations for System Settings Function Operation Default SettingCommand Center Operations Command Center FUNCTIONS/OPERATIONSelf Diagnostics Chart Fault LeD IndicationRemote Transmitter Operations Remote Control OperationSpeed Blower Control Optional Flame Height Setting for Thermostatic ModeLevel Light Brightness Control Low Battery Detection Remote Control OperationON/OFF AUX Control Optional Child-Proof ProtectionBurner, Pilot and Control Compartment Cleaning and maintenanceGlass Door Vent SysteMStones Signature Command System TroubleshootingFirebox components and accessories Replacement PartsAccessories / Field Installed Options Description Qty WDV500Replacement Parts LP to Natural Gas Replacement PartsVent components Current Old Simpson Duravent Vent Components for 5 XOr Mhsc Selkirk Box Description Stones WDV Series Gas Fireplace Manufacturer Requirements MassachusettsFive Year Warranty Lifetime WarrantyBasic Warranty If Warranty Service is NeededModel Mhsc

WDV500 specifications

The Monessen Hearth WDV500 is a stylish and efficient direct vent gas fireplace designed to enhance any living space. This fireplace combines modern aesthetics with advanced technology to create a cozy atmosphere while ensuring optimal performance. With its sleek design and versatile installation options, it caters to various home styles, making it an ideal choice for homeowners looking to elevate their ambiance.

One of the standout features of the WDV500 is its direct vent system, which allows for safe and efficient operation. This system utilizes outside air for combustion, ensuring that indoor air quality is maintained. By drawing air from the outside and venting exhaust gases directly outside, the WDV500 minimizes heat loss and maximizes energy efficiency. This makes it an environmentally friendly option, aligning with contemporary sustainability practices.

The Monessen Hearth WDV500 is equipped with a variety of innovative technologies aimed at providing users with ease of use and improved functionality. The adjustable flame control allows homeowners to customize the intensity of the fire to suit their mood or occasion. Additionally, the WDV500 features a high-efficiency burner that generates an impressive heat output, ensuring that rooms are kept warm and inviting even during the coldest months.

In terms of design, the WDV500 offers multiple finish options and accessory features, allowing it to seamlessly blend into any decor. A stunning selection of logs, crystals, or stones enhances the visual appeal of the fireplace, giving it a contemporary touch that complements traditional or modern interiors alike.

Safety is a priority with the Monessen Hearth WDV500, which includes an automatic shut-off feature that engages if the unit experiences overheating, ensuring peace of mind for users. The fireplace's straightforward installation process further emphasizes its user-friendly design, suitable for both new builds and retrofitting into existing spaces.

Overall, the Monessen Hearth WDV500 represents a harmonious blend of technology, safety, and style. Whether for relaxation on chilly evenings or for entertaining guests, this versatile fireplace provides warmth and elegance, making it a perfect addition to any home. Its efficient performance, customizable features, and aesthetic appeal make the WDV500 a popular choice among discerning homeowners.