Monessen Hearth WDV500 manual Important Safety Information, Installer, Owner

Page 3

IMPORTANT SAFETY INFORMATION

WDV Series Gas Fireplace

 

 

INSTALLER

Please leave these instructions with the appliance.

OWNER

Please retain these instructions for future reference.

WARNING

Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace.

Any change to this fireplace or its controls can be dangerous.

Improper installation or use of this fireplace can cause serious injury or death from fire, burns, explosions, electrical shock and carbon monoxide poisoning.

This fireplace is a vented product. This fireplace must be properly installed by a qualified service person. The glass door must be properly seated and sealed. If this unit is not properly installed by a qualified service person with glass door properly seated and sealed, combustion leakage can occur.

CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, the fire- place may not have been installed properly. Get fresh air at once! Have the fireplace inspected and serviced by a qualified service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.

2.For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

3.If you smell gas

shut off gas supply.

do not try to light any appliance.

do not touch any electrical switch; do not use any phone in your building .

immediately call your gas supplier from a neigh- bor’s phone. Follow the gas supplier’s instruc- tions.

4.Never install the fireplace

in a recreational vehicle

where curtains, furniture, clothing, or other flam- mable objects are less than 42" from the front, top, or sides of the fireplace

in high traffic areas

in windy or drafty areas

5.This fireplace reaches high temperatures. Keep chil- dren and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touch- ing.

6.Carefully supervise young children when they are in the room with fireplace.

7.Do not modify fireplace under any circumstances. Any parts removed for servicing must be replaced prior to operating fireplace.

8.Turn fireplace off and let cool before servicing, install- ing, or repairing. Only a qualified service person should install, service, or repair the fireplace. Have burner system inspected annually by a qualified service person.

9.You must keep control compartments, burners, and circulating air passages clean. More frequent clean- ing may be needed due to excessive lint and dust. Turn off the gas valve and pilot light before cleaning fireplace.

10.Have venting system inspected annually by a quali- fied service person. If needed, have venting system cleaned or repaired. Refer to Cleaning and Mainte- nance, Page 36.

11.Keep the area around your fireplace clear of combus- tible materials, gasoline, and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or deco- rations on or around fireplace.

12.Do not use this fireplace to cook food or burn paper or other objects.

13.Never place anything on top of fireplace.

78D0011

Image 3
Contents WDV Wideview Direct Vent Gas Fireplace Operating Instructions Signature Command SystemImportant Safety Information InstallerOwner As wellhead gas Code ApprovalNever connect unit to private non-utility Gas wells. This gas is commonly knownHigh Elevations Product features and code approvalFireplace and Framing Dimensions Fireplace & Framing DimensionsPRE-INSTALLATION Information Fireplace LocationCold Climate Insulation Side View ClearancesClearances to combustibles Mantel clearancesFront face of fireplace Never install combustible materials overSecure Fireplace to floor or framing Finishing MaterialFailure to follow these instructions will Venting Installation InformationInstallation precautions Void the warrantyFor horizontal termination Vent installationInstallation planning Installing a vent system in an outside chaseMinimum distances Venting installationAir Supply Inlet Area Where Terminals Not Permitted For horizontal termination Inside Corner DetailHow To Use The Vent Graph Venting installationMaximum Three 3 90 Elbows Per Installation VERTICAL/Horizontal termination configurationsWall Below Grade InstallationsMaintained between the snorkel Vertical through-the-roof applicationsDo not back fill around snorkel Clearance of at least 4 must beFlat ceiling installation Venting installation Installation for vertical terminationTermination Heights for Vents Above Flat or Sloped Roofs Flex Vent Installation Flex Vent Installation Check gas type Fireplace installationInstalling gas piping to fireplace location Installation items neededPropane/LP Natural GasElectrical Wiring Do not use open flame to check for gas leaksImproper and dangerous operation Caut NIO AW RNI GN Command Center Wall InstallationSignature command Optional fan blower system Wiring to junction boxOptional Fan/Blower System Blotbldvsc Glass removal & light placement Light InstallationGlass Frame Removal Stone & glass placement Stone & Glass PlacementGlass only Placement What to do if YOU Smell GAS Signature command Operating InstructionsOPERATing Instructions Switch BoxBattery Installation FeaturesFunction Operation Default Setting Signature Command System Operation InstructionsSystem CONFIGURATION/SETUP Key Combinations for System SettingsFault LeD Indication Command Center FUNCTIONS/OPERATIONCommand Center Operations Self Diagnostics ChartRemote Transmitter Operations Remote Control OperationFlame Height Setting for Thermostatic Mode Speed Blower Control OptionalLevel Light Brightness Control Child-Proof Protection Remote Control OperationLow Battery Detection ON/OFF AUX Control OptionalBurner, Pilot and Control Compartment Cleaning and maintenanceVent SysteM Glass DoorStones Signature Command System TroubleshootingDescription Qty WDV500 Replacement PartsFirebox components and accessories Accessories / Field Installed OptionsReplacement Parts LP to Natural Gas Replacement PartsVent components Vent Components for 5 X Current Old Simpson DuraventOr Mhsc Selkirk Box Description Stones WDV Series Gas Fireplace Manufacturer Requirements MassachusettsIf Warranty Service is Needed Lifetime WarrantyFive Year Warranty Basic WarrantyModel Mhsc

WDV500 specifications

The Monessen Hearth WDV500 is a stylish and efficient direct vent gas fireplace designed to enhance any living space. This fireplace combines modern aesthetics with advanced technology to create a cozy atmosphere while ensuring optimal performance. With its sleek design and versatile installation options, it caters to various home styles, making it an ideal choice for homeowners looking to elevate their ambiance.

One of the standout features of the WDV500 is its direct vent system, which allows for safe and efficient operation. This system utilizes outside air for combustion, ensuring that indoor air quality is maintained. By drawing air from the outside and venting exhaust gases directly outside, the WDV500 minimizes heat loss and maximizes energy efficiency. This makes it an environmentally friendly option, aligning with contemporary sustainability practices.

The Monessen Hearth WDV500 is equipped with a variety of innovative technologies aimed at providing users with ease of use and improved functionality. The adjustable flame control allows homeowners to customize the intensity of the fire to suit their mood or occasion. Additionally, the WDV500 features a high-efficiency burner that generates an impressive heat output, ensuring that rooms are kept warm and inviting even during the coldest months.

In terms of design, the WDV500 offers multiple finish options and accessory features, allowing it to seamlessly blend into any decor. A stunning selection of logs, crystals, or stones enhances the visual appeal of the fireplace, giving it a contemporary touch that complements traditional or modern interiors alike.

Safety is a priority with the Monessen Hearth WDV500, which includes an automatic shut-off feature that engages if the unit experiences overheating, ensuring peace of mind for users. The fireplace's straightforward installation process further emphasizes its user-friendly design, suitable for both new builds and retrofitting into existing spaces.

Overall, the Monessen Hearth WDV500 represents a harmonious blend of technology, safety, and style. Whether for relaxation on chilly evenings or for entertaining guests, this versatile fireplace provides warmth and elegance, making it a perfect addition to any home. Its efficient performance, customizable features, and aesthetic appeal make the WDV500 a popular choice among discerning homeowners.