Napoleon Fireplaces GD19N, GD19P manual Rear Exit / Horizontal Termination

Page 13
Manual background

13

REAR EXIT / HORIZONTAL TERMINATION

(HT) > (VT)

Example 5:

 

90°

Simple venting configuration

 

 

 

90°

H4

(only two 90° elbows)

 

 

 

 

V2

 

H2

 

90°

 

 

 

H3

 

FIGURE 14

V1

45°

 

 

 

H1

FIGURE 15

90°

 

See graph to determine the required vertical rise VT for the required horizontal run HT

 

150

 

 

V1

=4 ft

147

 

 

V2

=1.5 ft

 

 

 

REQUIRED

 

 

 

VT

= V1 + V2 = 4 + 1.5 = 5.5 ft

VERTICAL

 

 

 

H1

=2 ft

RISE IN

 

 

 

H2

=1 ft

INCHES VT

 

 

 

H3

=1 ft

 

 

 

H4

=1.5 ft

 

 

 

 

 

100

 

 

HR

= H1

+ H2 + H3 + H4 = 2 + 1 + 1 + 1.5 = 5.5 ft

 

 

 

 

HO

= .03(four 90° elbows + one 45° elbow - 90°)

 

 

 

 

 

= .03(90 + 90 + 90 + 90 + 45 - 90) = 9.45 ft

 

 

 

 

HT

=HR + HO = 5.5 + 9.45 = 14.95 ft

66

 

 

 

HT + VT

= 14.95 + 5.5 = 20.45 ft

 

 

 

Formula 1:

HT < 3.5VT

 

 

 

 

 

50

 

 

 

 

3.5VT = 3.5 x 5.5 = 19.25 ft

 

 

 

 

 

 

14.95 < 19.25

 

 

 

 

Formula 2:

HT + VT < 24.75 feet

 

 

 

 

 

 

20.45 < 24.75

 

 

 

 

Since both formulas are met, this vent configuration is

12

10

 

 

acceptable.

 

 

 

 

 

 

 

 

0

5

 

15

 

 

 

 

3.4

12.5

19.

 

 

HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT

 

 

The shaded area within the lines represents acceptable values for HT and VT .

For vent configurations requiring more than two 90° elbows the following formulas apply:

Formula 1: HT < 3.5VT

Formula 2: HT + VT < 24.75 feet

W415-0612 / C / 01.25.08

Image 13
Contents SAFETY INFORMATION INSTALLATION AND OPERATION INSTRUCTIONSGD19N GD19PRETAIN THIS MANUAL FOR FUTURE REFERENCE TABLE of CONTENTSCONDITIONS AND LIMITATIONS GENERAL INFORMATION GENERAL INSTRUCTIONSCARE OF GLASS AND PLATED PARTS VENTING HORIZONTAL VENT SECTIONS VENT INSTALLATIONSVERTICAL VENT SECTIONS FOR SPECIFIC VENTING PARAMETERS, REFER TO PAGESSPECIAL VENT INSTALLATIONS TYPICAL VENT INSTALLATIONSREAR EXIT TOP EXITW415-0612 /C MINIMUM AIR TERMINAL LOCATION CLEARANCESFIREPLACE VENT EXIT VENTING APPLICATION FLOW CHARTREAR EXIT TOP EXITDEFINITIONS TOP EXIT / HORIZONTAL TERMINATIONELBOW VENT LENGTH VALUES HT VTTOP EXIT / HORIZONTAL TERMINATION H2 REAR EXIT / HORIZONTAL TERMINATIONHT VT REAR EXIT / HORIZONTAL TERMINATION HT VT TOP OR REAR EXIT VERTICAL TERMINATIONHT VT TOP EXIT CONVERSION HORIZONTAL INSTALLATION INSTALLATION WALL AND CEILING PROTECTIONVERTICAL INSTALLATION 3/4”HORIZONTAL AIR TERMINAL INSTALLATION USING FLEXIBLE VENT COMPONENTSVERTICAL AIR TERMINAL INSTALLATION FIREPLACE VENT CONNECTION AIR TERMINAL INSTALLATION VERTICAL VENTING INSTALLATIONRESTRICTING VERTICAL VENTS EXTENDED HORIZONTAL AND CORNERGAS INSTALLATION MOBILE HOME INSTALLATIONELECTRICAL INSTALLATION OPTIONAL WALL SWITCH INSTALLATIONREAR VENT FRAMINGTOP VENT Combustible Framing 0 to stand-offsFIGURES 41a&b MINIMUM MANTEL AND ENCLOSURE CLEARANCESFIREBOX FRONT FACING AND INSET KIT INSTALLATIONNIGHT LIGHT REPLACEMENT BLOWER INSTALLATIONBULB REPLACEMENT LENS ASSEMBLY INSTALLATIONGLASS DOOR INSTALLATION AND REMOVAL FINISHINGDOOR GLASS REPLACEMENT LOG PLACEMENTMAIN BURNER SWITCH LOGO PLACEMENTFLAME ADJUSTMENT NIGHT LIGHTTM SWITCHSee detail for optional wall switch GD-660wiring WIRING DIAGRAMMAINTENANCE OPERATION / MAINTENANCEFOR YOUR SAFETY READ BEFORE OPERATING OPERATING INSTRUCTIONSPILOT INJECTOR AND ORIFICE REPLACEMENT ADJUSTMENTSVENTURI ADJUSTMENT FLAME ADJUSTMENTREPLACEMENT PARTS REPLACEMENTSACCESSORIES FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OFW415-0612 /C SYMPTOM TROUBLE SHOOTING GUIDEPROBLEM TEST SOLUTIONPROBLEM SYMPTOMTEST SOLUTION Pilot lightsserviced annually depending on usage Fireplace Service HistoryThis fireplace must be W415-0612 /CW415-0612 /C