Example 7:

(HT) > (VT)

Simple venting configurations

FIGURE 17

See graph to determine the required vertical rise VT for the required horizontal run HT.

REQUIRED

VERTICAL

RISE IN

FEET VT

HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT

The shaded area within the lines represents acceptable values for HT and VT .

For vent configurations requiring more than two 90° elbow (top exit) or one 90° elbow (rear exit), the following formulas apply:

Formula 1: HT < 3VT

Formula 2: HT + VT < 35 feet

90°

 

 

90°

 

V3

 

 

 

 

V

 

H1

 

H

 

 

1

 

V2

2

 

 

 

 

 

 

 

 

90°

90°

 

 

 

 

 

FIGURE 18

15

Example 7:

V1

 

=2 ft

 

V2

 

=1 ft

V3

 

=1.5 ft

VT

 

= V1 + V2 + V3 = 2 + 1 + 1.5 = 4.5 ft

H1

 

=6 ft

H2

 

=2 ft

HR

 

= H1

+ H2 = 6 + 2 = 8 ft

HO

 

= .03(four 90° elbows - 90°)

 

 

= .03(90 + 90 + 90 + 90 - 90) = 8.1 ft

HT

+ VT

=HR + HO = 8 + 8.1 = 16.1 ft

HT

= 16.1 + 4.5 = 20.6 ft

Formula 1:

HT

<

3VT

 

 

 

 

 

 

3VT = 3 x 4.5 = 13.5 ft

 

 

 

16.1 > 13.5

Since this formula is not met, this vent configuration is unacceptable.

Formula 2: HT + VT < 35 feet 20.6 < 35

Since only formula 2 is met, this vent configuration is unacceptable and a new fireplace location or vent configuration will need to be established to satisfy both formulas.

Example 8:

 

 

 

90°

H2 45°

V2

 

 

 

 

 

 

 

 

 

H1

V1

H3

90°

 

 

 

 

 

 

 

 

 

90°

 

 

 

 

 

 

 

FIGURE 19

 

V1

 

=1.5 ft

 

 

 

 

V2

 

=5 ft

 

 

 

 

VT

 

= V1 + V2 = 1.5 + 5 = 6.5 ft

 

H1

 

=1 ft

 

 

 

 

H2

 

=1 ft

 

 

 

 

H3

 

=10.75 ft

 

 

 

HR

 

= H1

+ H2

+ H3

= 1 + 1 + 10.75 = 12.75 ft

 

HO

 

= .03(three 90° elbows + one 45° elbow - 90°)

 

 

= .03(90 + 90 + 90 + 45 - 90) = 6.75 ft

 

HT

 

=HR + HO

= 12.75 + 6.75 = 19.5 ft

 

HT

+ VT

= 19.5 + 6.5 = 26 ft

 

Formula 1:

HT < 3VT

 

 

 

 

 

 

3VT

= 3 x 6.5 = 19.5 ft

 

 

 

 

19.5 = 19.5

 

Formula 2: HT + VT < 35 feet 26 < 35

Since both formulas are met, this vent configuration is acceptable.

W415-0612 / C / 01.25.08

Image 15
Contents GD19P INSTALLATION AND OPERATION INSTRUCTIONSSAFETY INFORMATION GD19NRETAIN THIS MANUAL FOR FUTURE REFERENCE TABLE of CONTENTSCONDITIONS AND LIMITATIONS GENERAL INSTRUCTIONS GENERAL INFORMATIONCARE OF GLASS AND PLATED PARTS VENTING FOR SPECIFIC VENTING PARAMETERS, REFER TO PAGES VENT INSTALLATIONSHORIZONTAL VENT SECTIONS VERTICAL VENT SECTIONSTOP EXIT TYPICAL VENT INSTALLATIONSSPECIAL VENT INSTALLATIONS REAR EXITW415-0612 /C MINIMUM AIR TERMINAL LOCATION CLEARANCESTOP EXIT VENTING APPLICATION FLOW CHARTFIREPLACE VENT EXIT REAR EXITHT VT TOP EXIT / HORIZONTAL TERMINATIONDEFINITIONS ELBOW VENT LENGTH VALUESTOP EXIT / HORIZONTAL TERMINATION REAR EXIT / HORIZONTAL TERMINATION H2HT VT REAR EXIT / HORIZONTAL TERMINATION HT VT TOP OR REAR EXIT VERTICAL TERMINATIONHT VT TOP EXIT CONVERSION 3/4” INSTALLATION WALL AND CEILING PROTECTIONHORIZONTAL INSTALLATION VERTICAL INSTALLATIONUSING FLEXIBLE VENT COMPONENTS HORIZONTAL AIR TERMINAL INSTALLATIONVERTICAL AIR TERMINAL INSTALLATION FIREPLACE VENT CONNECTION EXTENDED HORIZONTAL AND CORNER VERTICAL VENTING INSTALLATIONAIR TERMINAL INSTALLATION RESTRICTING VERTICAL VENTSOPTIONAL WALL SWITCH INSTALLATION MOBILE HOME INSTALLATIONGAS INSTALLATION ELECTRICAL INSTALLATIONCombustible Framing 0 to stand-offs FRAMINGREAR VENT TOP VENTFIGURES 41a&b MINIMUM MANTEL AND ENCLOSURE CLEARANCESFIREBOX FRONT FACING AND INSET KIT INSTALLATIONLENS ASSEMBLY INSTALLATION BLOWER INSTALLATIONNIGHT LIGHT REPLACEMENT BULB REPLACEMENTLOG PLACEMENT FINISHINGGLASS DOOR INSTALLATION AND REMOVAL DOOR GLASS REPLACEMENTNIGHT LIGHTTM SWITCH LOGO PLACEMENTMAIN BURNER SWITCH FLAME ADJUSTMENTSee detail for optional wall switch GD-660wiring WIRING DIAGRAMOPERATING INSTRUCTIONS OPERATION / MAINTENANCEMAINTENANCE FOR YOUR SAFETY READ BEFORE OPERATINGFLAME ADJUSTMENT ADJUSTMENTSPILOT INJECTOR AND ORIFICE REPLACEMENT VENTURI ADJUSTMENTFOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF REPLACEMENTSREPLACEMENT PARTS ACCESSORIESW415-0612 /C TEST SOLUTION TROUBLE SHOOTING GUIDESYMPTOM PROBLEMPilot lights SYMPTOMPROBLEM TEST SOLUTIONW415-0612 /C Fireplace Service Historyserviced annually depending on usage This fireplace must beW415-0612 /C