Napoleon Fireplaces GD19N, GD19P manual Minimum Mantel And Enclosure Clearances, FIGURES 41a&b

Page 23
MINIMUM MANTEL AND ENCLOSURE CLEARANCES

23

MINIMUM MANTEL AND ENCLOSURE CLEARANCES

Mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed. Combustible materials must be installed flush with the front of the fireplace but must not cover any of the black face-area of the fireplace. Non-combustible material (brick, stone or ceramic tile) may protrude past the face of the fireplace.

FIGURES 41a&b

8” MANTEL

6”

 

 

8”6”

4”

 

4”

2”

TOP OF

 

2”

FIREPLACE

 

 

 

COMBUSTIBLE

6”

39 1/8

331/8

NON-COMBUSTIBLE

BRICK

0” IF NON-COMBUSTIBLE

2” FINISHING IS USED SUCH AS BRICK AND STONE.

1”

FIGURES 41a&b 26 3/8” MINIMUM

PLUS RISE *

M

 

A

 

N

 

T

 

E

 

L

 

H

 

E

 

I

 

G

 

H

 

T

 

MANTEL DEPTH

 

COMBUSTIBLE

NON-COMBUSTIBLE

 

 

BRICK 0” IF

 

2”

NON-COMBUSTIBLE

6”

FINISHING IS USED

 

 

SUCH AS BRICK

 

 

 

 

AND STONE.

20”

1”

FIGURE 43

 

! WARNING

Do not build into this area - it must be left clear to provide adequate

clearance for the vent. In this 14” wide area centred along the front of

 

the fireplace, no combustibles are allowed.

 

1 1/2

 

MAXIMUM

 

14”

 

MINIMUM

*FINISHING

1 1/2

MAXIMUM

531/8

33 1/8

1”

1”

Manual backgroundManual background 4317//88"”MINIMUM

PLUS RISE **

MATERIAL

 

OPENING

 

HEIGHT

1/4” *

MUST BE

34 1/8

*KEEP

 

FACING

 

MATERIAL

 

1/4” FROM

 

SIDE OF

 

UNIT.

*FINISHING MATERIAL

 

OPENING WIDTH

 

MUST BE 20 1/4

13 1/4

1”

FIGURE 42

* Dimensions must be maintained for the facing kit to cover the

opening.

FIGURE 44

 

The fireplace requires a minimum enclosure height of 53 1/8" for a top vent, and 39 1/8" for a rear vent. For temperature requirements, the enclosure space around and above the fireplace must be left unobstructed. See figures 42 and 43.

W415-0612 / C / 01.25.08

Image 23
Contents GD19P INSTALLATION AND OPERATION INSTRUCTIONSSAFETY INFORMATION GD19NRETAIN THIS MANUAL FOR FUTURE REFERENCE TABLE of CONTENTSCONDITIONS AND LIMITATIONS CARE OF GLASS AND PLATED PARTS GENERAL INSTRUCTIONSGENERAL INFORMATION VENTING FOR SPECIFIC VENTING PARAMETERS, REFER TO PAGES VENT INSTALLATIONSHORIZONTAL VENT SECTIONS VERTICAL VENT SECTIONSTOP EXIT TYPICAL VENT INSTALLATIONSSPECIAL VENT INSTALLATIONS REAR EXITW415-0612 /C MINIMUM AIR TERMINAL LOCATION CLEARANCESTOP EXIT VENTING APPLICATION FLOW CHARTFIREPLACE VENT EXIT REAR EXITHT VT TOP EXIT / HORIZONTAL TERMINATIONDEFINITIONS ELBOW VENT LENGTH VALUESTOP EXIT / HORIZONTAL TERMINATION HT VT REAR EXIT / HORIZONTAL TERMINATIONH2 REAR EXIT / HORIZONTAL TERMINATION HT VT TOP OR REAR EXIT VERTICAL TERMINATIONHT VT TOP EXIT CONVERSION 3/4” INSTALLATION WALL AND CEILING PROTECTIONHORIZONTAL INSTALLATION VERTICAL INSTALLATIONVERTICAL AIR TERMINAL INSTALLATION USING FLEXIBLE VENT COMPONENTSHORIZONTAL AIR TERMINAL INSTALLATION FIREPLACE VENT CONNECTION EXTENDED HORIZONTAL AND CORNER VERTICAL VENTING INSTALLATIONAIR TERMINAL INSTALLATION RESTRICTING VERTICAL VENTSOPTIONAL WALL SWITCH INSTALLATION MOBILE HOME INSTALLATIONGAS INSTALLATION ELECTRICAL INSTALLATIONCombustible Framing 0 to stand-offs FRAMINGREAR VENT TOP VENTFIGURES 41a&b MINIMUM MANTEL AND ENCLOSURE CLEARANCESFIREBOX FRONT FACING AND INSET KIT INSTALLATIONLENS ASSEMBLY INSTALLATION BLOWER INSTALLATIONNIGHT LIGHT REPLACEMENT BULB REPLACEMENTLOG PLACEMENT FINISHINGGLASS DOOR INSTALLATION AND REMOVAL DOOR GLASS REPLACEMENTNIGHT LIGHTTM SWITCH LOGO PLACEMENTMAIN BURNER SWITCH FLAME ADJUSTMENTSee detail for optional wall switch GD-660wiring WIRING DIAGRAMOPERATING INSTRUCTIONS OPERATION / MAINTENANCEMAINTENANCE FOR YOUR SAFETY READ BEFORE OPERATINGFLAME ADJUSTMENT ADJUSTMENTSPILOT INJECTOR AND ORIFICE REPLACEMENT VENTURI ADJUSTMENTFOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF REPLACEMENTSREPLACEMENT PARTS ACCESSORIESW415-0612 /C TEST SOLUTION TROUBLE SHOOTING GUIDESYMPTOM PROBLEMPilot lights SYMPTOMPROBLEM TEST SOLUTIONW415-0612 /C Fireplace Service Historyserviced annually depending on usage This fireplace must beW415-0612 /C