Napoleon Fireplaces GD19P Using Flexible Vent Components, Horizontal Air Terminal Installation

Page 18
USING FLEXIBLE VENT COMPONENTS
FIGURE 25

18

USING FLEXIBLE VENT COMPONENTS

ELBOW

SPACERS

!WARNING

Do not allow the 4" flexible vent pipe to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. A 1 1/4” air gap between the 4" and 7" flexible vent pipes all around is required for safe operation. A spacer is required at the start, middle and end of each elbow to ensure this gap is maintained. Spacers are attached to the 4" flexible vent pipe at predetermined intervals to maintain a 1-1/4” air gap to the 7" flexible vent pipe. These spacers

must not be removed.

Use only approved flexible vent pipe kits marked:

FIGURES 22a&b

“Wolf Steel Approved Venting” as identified by the stamp only on the 7” flexible vent pipe.

Six inches (6") is the minimum bend radius allowed for the seven inch (7") diameter flexible vent pipe.

For optimum performance it is recommended that all horizontal runs have a minimum 1" rise per foot using flexible vent components.

For safe and proper operation of the fireplace, follow the venting instructions exactly.

All 4" flexible vent pipe and 7" flexible vent pipe joints may be sealed using high temperature sealant W573-0002 (not supplied) or the high temperature sealant W573-0002 Mill Pac (not supplied). However, the high temperature sealant W573-0007 Mill Pac (not supplied) must be used on the joint connecting the 4" flexible vent and the exhaust flue collar.

HORIZONTAL AIR TERMINAL INSTALLATION

For safe and proper operation of the fireplace, follow the venting instructions exactly.

1.Stretch the 4" flexible vent pipe to the required length taking into account the additional length needed for the finished wall surface. Slip the vent pipe a minimum of 2" over the inner sleeve of the air terminal and secure with 3 #8 screws. Apply a heavy bead of the high temperature sealant W573-0007 (not supplied).

NOTE: If using pipe clamps to connect vent components, 3 screws must also be used to ensure the connection cannot slip off.

CAUT

 

ATTENTI

ION-

 

HOT

 

ON-

 

CHAUD

CAULKING

4" FLEXIBLE VENT PIPE

7" FLEXIBLE

2. Using the 7" flexible vent pipe, slide over the outer combustion air

 

 

2" OVERLAP

VENT PIPE

 

 

 

sleeve of the air terminal and secure with 3 #8 screws. Seal using high

 

 

 

 

 

temperature sealant W573-0002 (not supplied).

FIGURE 23

 

HIGH TEMPERATURE

3. Insert the vent pipes through the firestop maintaining the required

#10x2"

 

SEALANT

 

SCREWS

 

 

clearance to combustibles. Holding the air terminal (lettering in an upright,

HIGH

 

#8 X 1/2”

 

 

readable position), secure to the exterior wall and make weather tight by

 

 

 

 

SELF DRILLING

sealing with caulking (not supplied).

TEMPERATURE

SCREWS AND

FIGURE 24

4. If more vent pipe needs to be used to reach the fireplace, couple them

SEALANT

 

WASHERS

 

 

 

 

 

together as illustrated. The vent system must be supported approximately

 

 

4” COUPLER

 

7” COUPLER

every 3 feet for both vertical and horizontal runs. Use noncombustible

 

 

 

 

 

strapping to maintain the minimum 1" clearance to combustibles.

 

 

 

7” FLEXIBLE

 

 

 

 

The air terminal mounting plate may be recessed into the exterior wall

7” FLEXIBLE

 

 

VENT PIPE

 

4”

 

 

or siding by 1½", the depth of the return flange.

VENT PIPE

 

FLEXIBLE

 

 

VENT PIPE

VERTICAL AIR TERMINAL INSTALLATION

1. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having

jurisdiction or the optional roof support. Figure 25.

2.Stretch the 4" flexible vent pipe to the required length. Slip the 4" flexible vent pipe a minimum of 2” over the inner sleeve of the air terminal connector and secure with 3 #8 screws. Seal using a heavy bead of high temperature sealant W573-0007 (not supplied). Figure 26.

NOTE: If using pipe clamps to connect vent components, 3 screws must also be used to ensure the connection cannot slip off.

3. Repeat using the 7" flexible vent pipe, using a heavy bead of high temperature

ROOF SUPPORT

sealant W573-0002 (not supplied). Figure 26.

 

W415-0612 / C / 01.25.08

Image 18
Contents GD19N INSTALLATION AND OPERATION INSTRUCTIONSSAFETY INFORMATION GD19PTABLE of CONTENTS RETAIN THIS MANUAL FOR FUTURE REFERENCECONDITIONS AND LIMITATIONS GENERAL INSTRUCTIONS GENERAL INFORMATIONCARE OF GLASS AND PLATED PARTS VENTING VERTICAL VENT SECTIONS VENT INSTALLATIONSHORIZONTAL VENT SECTIONS FOR SPECIFIC VENTING PARAMETERS, REFER TO PAGESREAR EXIT TYPICAL VENT INSTALLATIONSSPECIAL VENT INSTALLATIONS TOP EXITMINIMUM AIR TERMINAL LOCATION CLEARANCES W415-0612 /CREAR EXIT VENTING APPLICATION FLOW CHARTFIREPLACE VENT EXIT TOP EXITELBOW VENT LENGTH VALUES TOP EXIT / HORIZONTAL TERMINATIONDEFINITIONS HT VTTOP EXIT / HORIZONTAL TERMINATION REAR EXIT / HORIZONTAL TERMINATION H2HT VT REAR EXIT / HORIZONTAL TERMINATION TOP OR REAR EXIT VERTICAL TERMINATION HT VTHT VT TOP EXIT CONVERSION VERTICAL INSTALLATION INSTALLATION WALL AND CEILING PROTECTIONHORIZONTAL INSTALLATION 3/4”USING FLEXIBLE VENT COMPONENTS HORIZONTAL AIR TERMINAL INSTALLATIONVERTICAL AIR TERMINAL INSTALLATION FIREPLACE VENT CONNECTION RESTRICTING VERTICAL VENTS VERTICAL VENTING INSTALLATIONAIR TERMINAL INSTALLATION EXTENDED HORIZONTAL AND CORNERELECTRICAL INSTALLATION MOBILE HOME INSTALLATIONGAS INSTALLATION OPTIONAL WALL SWITCH INSTALLATIONTOP VENT FRAMINGREAR VENT Combustible Framing 0 to stand-offsMINIMUM MANTEL AND ENCLOSURE CLEARANCES FIGURES 41a&bFRONT FACING AND INSET KIT INSTALLATION FIREBOXBULB REPLACEMENT BLOWER INSTALLATIONNIGHT LIGHT REPLACEMENT LENS ASSEMBLY INSTALLATIONDOOR GLASS REPLACEMENT FINISHINGGLASS DOOR INSTALLATION AND REMOVAL LOG PLACEMENTFLAME ADJUSTMENT LOGO PLACEMENTMAIN BURNER SWITCH NIGHT LIGHTTM SWITCHWIRING DIAGRAM See detail for optional wall switch GD-660wiringFOR YOUR SAFETY READ BEFORE OPERATING OPERATION / MAINTENANCEMAINTENANCE OPERATING INSTRUCTIONSVENTURI ADJUSTMENT ADJUSTMENTSPILOT INJECTOR AND ORIFICE REPLACEMENT FLAME ADJUSTMENTACCESSORIES REPLACEMENTSREPLACEMENT PARTS FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OFW415-0612 /C PROBLEM TROUBLE SHOOTING GUIDESYMPTOM TEST SOLUTIONTEST SOLUTION SYMPTOMPROBLEM Pilot lightsThis fireplace must be Fireplace Service Historyserviced annually depending on usage W415-0612 /CW415-0612 /C