OPERATION / MAINTENANCE

29

OPERATION / MAINTENANCE

Purge all gas lines with the glass door of the fireplace removed or opened. Assure that a continuous gas flow is at the burner before installing the door.

When lit for the first time, the fireplace will emit a slight odour by the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again.

After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may omit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. In both cases, open a window to sufficiently ventilate the room.

FOR YOUR SAFETY READ BEFORE OPERATING

!WARNING

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING

PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A. THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUTOMATICALLY LIGHTS THE PILOT. DO NOT TRY TO LIGHT BY HAND.

B. BEFORE OPERATING SMELL ALL AROUND THE FIREPLACE AREA FOR GAS AND NEXT TO THE FLOOR BECAUSE SOME GAS IS HEAVIER THAN AIR AND WILL SETTLE ON THE FLOOR.

C. USE ONLY YOUR HAND TO TURN THE GAS CONTROL KNOB. NEVER USE TOOLS. IF THE KNOB WILL NOT TURN BY HAND, DO NOT TRY TO REPAIR IT. CALL A QUALIFIED SERVICE TECHNICIAN. FORCE OR ATTEMPTED REPAIR MAY RESULT IN A FIRE OR EXPLOSION.

D. DO NOT USE THIS FIREPLACE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE FIREPLACE AND REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.

WHAT TO DO IF YOU SMELL GAS:

TURN OFF ALL GAS TO THE FIREPLACE.

OPEN WINDOWS.

DO NOT TRY TO LIGHT ANY APPLIANCE.

DO NOT TOUCH ANY ELECTRIC SWITCH; DO NOT USE ANY PHONE IN YOUR BUILDING.

IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOUR'S PHONE FOLLOW THE GAS SUPPLIER'S INSTRUCTIONS.

IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT.

OPERATING INSTRUCTIONS

1.STOP! READ THE ABOVE SAFETY INFORMATION ON THIS LABEL.

2.TURN REMOTE WALL SWITCH TO OFF POSITION.

3.TURN OFF ALL ELECTRIC POWER TO THE FIREPLACE AND REMOVE BATTERIES.

4.THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUTOMATICALLY LIGHTS THE PILOT. DO NOT TRY TO LIGHT THE PILOT BY HAND.

5.TURN MANUAL SHUTOFF VALVE CLOCKWISE FOR YOUR SAFETY READ BEFORE OPERATINGTO OFF.

6.OPEN THE GLASS DOOR.

7.WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS. IF YOU SMELL GAS INCLUDING NEAR THE FLOOR, STOP! FOLLOW "B" IN THE ABOVE SAFETY INFORMATION ON THIS LABEL. IF YOU DON'T SMELL GAS GO TO THE NEXT STEP.

8.CLOSE THE GLASS DOOR.

9.TURN MANUAL SHUTOFF VALVE COUNTER-

CLOCKWISE OPERATING INSTRUCTIONS TO ON.

10.TURN ON ALL ELECTRIC POWER TO THE FIREPLACE AND RE-INSTALL BATTERIES.

11.TURN ON REMOTE WALL SWITCH TO ON POSITION.

12.IF FIREPLACE WILL NOT OPERATE, FOLLOW INSTRUCTIONS "TO TURN OFF GAS" AND CALL YOUR SERVICE TECHNICIAN OR GAS SUPPLIER.

Manual Shut-off Valve

Shown in “OFF”

TO TURN OFF GAS position.

TO TURN OFF GAS

1.TURN OFF REMOTE WALL SWITCH TO THE FIREPLACE.

2.TURN OFF ALL ELECTRICAL POWER TO THE FIREPLACE IF SERVICE IS TO BE PERFORMED.

3.TURN MANUAL SHUTOFF VALVE CLOCKWISE MAINTENANCE TO OFF. DO NOT FORCE.

MAINTENANCE

TURN OFF THE GAS AND UNPLUG ELECTRICAL POWER BEFORE SERVICING THE STOVE:

Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. This stove and its venting system should be inspected before use and at least annually by a qualified service person. The fireplace area must be kept clear and free of combustible materials, gasoline or other flammable vapours and liquids. The flow of combustion and ventilation air must not be obstructed.

1.In order to properly clean the burner and pilot assembly, remove the logs exposing both assemblies.

2.Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year.

3.Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly.

4.Check to see that the pilot flames are large enough to engulf the sensor on one leg and reaches toward the burner on the other leg.

5.Replace the cleaned logs.

6.Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on.

A 5-10 second total light-up period is satisfactory. If ignition takes

longer, consult your Napoleon® dealer/distributor.

7.Check that the door gasketing is not broken or missing.

8.If for any reason the vent air intake system is disassembled, re-install and re-seal per the instructions provided for the initial installation.

W415-0612 / C / 01.25.08

Image 29
Contents SAFETY INFORMATION INSTALLATION AND OPERATION INSTRUCTIONSGD19N GD19PRETAIN THIS MANUAL FOR FUTURE REFERENCE TABLE of CONTENTSCONDITIONS AND LIMITATIONS CARE OF GLASS AND PLATED PARTS GENERAL INSTRUCTIONSGENERAL INFORMATION VENTING HORIZONTAL VENT SECTIONS VENT INSTALLATIONSVERTICAL VENT SECTIONS FOR SPECIFIC VENTING PARAMETERS, REFER TO PAGESSPECIAL VENT INSTALLATIONS TYPICAL VENT INSTALLATIONSREAR EXIT TOP EXITW415-0612 /C MINIMUM AIR TERMINAL LOCATION CLEARANCESFIREPLACE VENT EXIT VENTING APPLICATION FLOW CHARTREAR EXIT TOP EXITDEFINITIONS TOP EXIT / HORIZONTAL TERMINATIONELBOW VENT LENGTH VALUES HT VTTOP EXIT / HORIZONTAL TERMINATION HT VT REAR EXIT / HORIZONTAL TERMINATIONH2 REAR EXIT / HORIZONTAL TERMINATION HT VT TOP OR REAR EXIT VERTICAL TERMINATIONHT VT TOP EXIT CONVERSION HORIZONTAL INSTALLATION INSTALLATION WALL AND CEILING PROTECTIONVERTICAL INSTALLATION 3/4”VERTICAL AIR TERMINAL INSTALLATION USING FLEXIBLE VENT COMPONENTSHORIZONTAL AIR TERMINAL INSTALLATION FIREPLACE VENT CONNECTION AIR TERMINAL INSTALLATION VERTICAL VENTING INSTALLATIONRESTRICTING VERTICAL VENTS EXTENDED HORIZONTAL AND CORNERGAS INSTALLATION MOBILE HOME INSTALLATIONELECTRICAL INSTALLATION OPTIONAL WALL SWITCH INSTALLATIONREAR VENT FRAMINGTOP VENT Combustible Framing 0 to stand-offsFIGURES 41a&b MINIMUM MANTEL AND ENCLOSURE CLEARANCESFIREBOX FRONT FACING AND INSET KIT INSTALLATIONNIGHT LIGHT REPLACEMENT BLOWER INSTALLATIONBULB REPLACEMENT LENS ASSEMBLY INSTALLATIONGLASS DOOR INSTALLATION AND REMOVAL FINISHINGDOOR GLASS REPLACEMENT LOG PLACEMENTMAIN BURNER SWITCH LOGO PLACEMENTFLAME ADJUSTMENT NIGHT LIGHTTM SWITCHSee detail for optional wall switch GD-660wiring WIRING DIAGRAMMAINTENANCE OPERATION / MAINTENANCEFOR YOUR SAFETY READ BEFORE OPERATING OPERATING INSTRUCTIONSPILOT INJECTOR AND ORIFICE REPLACEMENT ADJUSTMENTSVENTURI ADJUSTMENT FLAME ADJUSTMENTREPLACEMENT PARTS REPLACEMENTSACCESSORIES FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OFW415-0612 /C SYMPTOM TROUBLE SHOOTING GUIDEPROBLEM TEST SOLUTIONPROBLEM SYMPTOMTEST SOLUTION Pilot lightsserviced annually depending on usage Fireplace Service HistoryThis fireplace must be W415-0612 /CW415-0612 /C