Vermont Casting Encore NC 1450 installation instructions Draft Management

Page 26

Encore 1450 Non-Catalytic Woodburning Stove

Draft Management

A stove is part of a system which includes the chim- ney, the operator, the fuel and the home. Each part of the system affects how well the stove operates. When there is a good match between all the parts, the system works well.

Wood stove or insert operation depends on natural (unforced) draft. Natural draft occurs when the smoke is hotter (and therefore lighter) than the outdoor air at the top of the chimney. The larger the temperature difference, the stronger the draft. As the smoke rises from the chimney it provides suction or ‘draw’ that pulls air into the stove for combustion. A slow, lazy fire with the stove’s air inlets fully open indicates a weak draft. A brisk fire, supported only by air entering the stove through the normal inlets, indicates a good draft. The stove’s air inlets are passive; they regulate how much air can enter the stove, but depend entirely on the draft of the chimney.

Depending on the features of your installation - (i.e. metal or masonry chimney installed, inside or outside the house, matched to the stove’s outlet or oversized) - your system may warm up quickly or it may take a while to warm up and operate well. With an ‘airtight’ stove or insert, one which restricts the amount of air getting into the firebox, the chimney must keep the smoke warm all the way to the outdoors. Some chimneys do this better than others. Here is a list of features and their effects.

Masonry Chimney

Masonry is a traditional material for chimneys, but it can perform poorly when it serves an ‘airtight’ stove. Masonry is a very effective ‘heat sink’ - it absorbs a lot of heat. It can cool the smoke enough to diminish draft. The bigger the chimney, the longer it takes to warm up. It’s often very difficult to warm up an outdoor masonry chimney, especially an oversized one, and keep it warm enough to maintain an adequate draft.

Metal Chimney

Most factory-made metal chimneys have a layer of insulation around the inner flue. This insulation keeps the smoke warm. The insulation is less dense than ma- sonry, so a steel chimney warms up more quickly than a masonry chimney. Metal doesn’t have the good looks of masonry, but it often performs much better.

Indoor / Outdoor location

Because the chimney must keep the smoke warm, it is best to locate it inside the house. The relatively warm house then surrounds the chimney keeping it warm. This also means that heat from the chimney walls will transfer to the house and not be wasted outdoors. An indoor chimney will not lose its heat to the outdoors, so

it takes less heat from the stove to heat it up and keep it warm.

Flue Sizing

The interior size of a chimney for an ‘airtight’ stove should match the size of the stove’s flue outlet. When a chimney serves an airtight stove, “more” is not “better”; in fact, it can be a disadvantage. Exhaust gases move more slowly through larger chimneys and can lose more heat to the chimney walls. This weakens the draft strength. If an oversized flue is also outside the house, the heat it absorbs gets transferred to the outdoor air and the flue is further cooled.

It’s common for a masonry flue, especially one serving a fireplace, to be oversized for the stove. It can take quite a while to warm up such a flue, and the results can be disappointing. The best solution to an oversized flue is an insulated steel chimney liner, the same diam- eter as the stove or insert’s flue outlet; the liner keeps the exhaust warm, and the result is a stronger draft. An uninsulated liner is a second choice - the liner keeps the exhaust path restricted to its original size, but the air around the liner must still be heated. This makes the warm-up process take longer.

Pipe & Chimney Layout

Every turn the exhaust must take as it travels to the chimney top will slow it down. The ideal pipe and chim- ney layout is straight up from the stove, and into a verti- cal chimney. If you are starting from scratch, use this layout if possible. If the stovepipe must turn to enter a chimney, locate the thimble about midway between the stove top and the ceiling. This achieves several goals: it allows the exhaust gases to speed up before turning, it leaves some pipe in the room for heat transfer, and gives you long-term flexibility to install a future stove without relocating the thimble.

There should be no more than 8 feet (2.4m) of single- wall stove pipe between the stove and a chimney; lon- ger runs can cool the exhaust gases enough to cause draft and creosote problems. Use double-wall stove pipe for long runs.

Single venting

Each ‘airtight’ stove requires its own chimney. If an air- tight stove is vented to a flue that also serves an open fireplace, it is easier for the chimney draft to pull air in through those channels than it is to pull air through the stove, and performance suffers. Imagine a vacuum cleaner with a hole in the hose to see the effect here. In some cases the other appliance can even cause a negative draft through the airtight, and result in a dan- gerous draft reversal.

26

30002425

Image 26
Contents Encore Table of Contents WelcomeEncore dimensions SpecificationsChimney Height InstallationOutside Air Prefabricated Chimneys What Kind of Chimney to UseMasonry Chimneys Chimney SizeDouble-wall Chimney Connectors Chimney Connector GuidelinesSingle-wall Chimney Connectors Fireplace Installations Securing the Single-wall Connector to a Masonry ChimneyFreestanding Installations Above the FireplaceThrough the Fireplace Wall Pass-ThroughsFloor Protection An approved wall pass-through for the United StatesFloor Protection for Fireplace Installations CanadaWall Shields Keep the Stove a Safe Distance From Surrounding MaterialsReducing Clearances Safely with Shields Chimney Connector Heat Shields Fireplace Mantel and Trim ShieldsAlcove Installations Construction RequirementsCutaway perspective of acolve installation Encore NC Clearance Chart Unprotected Surfaces Protected SurfacesEncore Clearance Diagrams BcefWall Shield Requirements for Common Installations Corner Parallel Installations Assembly Fan Kit Installation Fan installation Kit #Single Air Control Regulates Heat Output and Burn Time OperationEncore NC Controls Damper Directs Air Flow Within the StoveBurn Only High-Quality Wood Infrared Reflective Glass Panels For Clear Fire ViewingAndirons Help Protect the Glass Starting and Maintaining a Wood Fire Use the Air Control Settings That Work Best for YouConditioning Your Stove Refuel While the Embers Are Still Hot Add larger pieces of wood as the fire begins to burn wellAsh Removal and Disposal Draft Management Fuel Draft TestingCreosote Back-puffingMaintenance Replace the Stove Gaskets as Needed Adjust the Door LatchesTighten the Damper Handle as Needed Chimney System Creosote Adjust the Door If NecessaryAll Gasketed Construction Maintenance Schedule Stove Chimney ConnectorEncore Non-Catalytic Woodburning Stove Encore Woodburning Stove Shell Enamel Parts Encore NC Model Limited Lifetime Warranty CFM Corporation