Jotul GF 400 DV Co-linear Vent Installation, These installation requirements must be followed

Page 12

Co-linear Vent Installation

The GF 400 DV Sebago may be vented through a ma- sonry or Class A prefabricated chimney using a Co-linear Flexible Vent system approved for use with a solid-fuel burning fireplace. When installed in the manner de- scribed below, this system can improve the performance of the appliance in cold climate situations, as well as simplify the vent installation. See fig. 13.

These installation requirements must be followed:

1.Use the guidelines for Co-linear Vent Termination appropriate for your gas type on pages 10 - 11.

Exhaust Gas

Max. Co-linear Height - 35 ft. (10.66 m)

Min. Co-linear Height - 10 ft. (3.05 m)

High Wind Cap

Intake Air

1.Prior to the installation the chimney flue must be thoroughly cleaned and inspected by a qualified chimney service person.

2.In a masonry chimney, a fireclay liner must be present the entire length of the chimney.

3.Prefabricated chimneys must be UL 103 or ULC S-629 listed and have a minimum INSIDE diameter of 6 inches, (150 mm).

4.No appliance can be installed into a chimney flue serving any other appliance of any kind.

5.THE AIR INTAKE FLEX PIPE MUST EXTEND 6 FEET BEYOND THE DAMPER AREA OF THE FIREPLACE.

6.If the intake flex duct does not extend the full length of the chimney and connect to both the unit and the termination cap, A METAL BLOCK OFF PLATE MUST BE CONSTRUCTED AND INSTALLED ABOVE THE UNIT PRIOR TO THE END OF THE INTAKE FLEX AND MUST COMPLETELY SEAL THE CHIMNEY FLUE FROM THE ROOM.

Consult with the local code authority having juris- diction before proceeding with this type of installation.

Refer to the vent manufacturer’s instructions for specific installation requirements.

WARNING: FAILURE TO POSITION THE PARTS AND STOVE IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED FOR USE WITH THIS APPLIANCE MAY RESULT IN PROP- ERTY DAMAGE OR PERSONAL INJURY. BE SURE TO MAINTAIN THE PROPER CLEARANCES TO COMBUSTIBLES AS DEFINED IN THIS MANUAL AND IN THE INSTRUC- TIONS PROVIDED WITH EACH VENT COMPONENT.

 

The Air

 

Intake Flex

 

pipe must

 

extend

 

beyond the

The chimney

damper.

 

must be sealed

Dual 3”Flex

off from the

Liners

room by a steel

 

plate at the

 

damper area.

 

 

Max. offset

 

24”

 

(609 mm)

Figure 13. Co-linear Adaptor installed through a masonry chimney. Components shown may differ somewhat from manufacturer to manufacturer.

29” to top of Co-linear

25 1/2” Adapter. to center

of flue collar

Figure 14. Simpson Dura-Vent #923GCL Co-linear Adaptor is shown - other manufacturer’s components may differ. Subtract 2 1/4” for Short Legs.

12

Image 12
Contents Jøtul GF 400 DV Sebago Gas Heater Welcome to Jøtul Table of Contents Jøtul GF 400 DV Sebago Direct Vent Gas HeaterGF 400 DV Sebago Specifications Suggested Tools for Installation and ServiceInput Rates Hardware Bag Contents Unpacking your stoveGlass Panel Safety Information LocationHearth Requirements Alcove Installation Minimum Clearances from the Vent Pipe to CombustiblesHorizontal Run Vertical RunVenting Requirements Vent RestrictionIntake Air Restrictor Exhaust RestrictorVertical Vent Termination Front LEG Back„ Minimum Vertical run must be at least 8 ft .43 m Vent Termination Zones Natural Gas Vertical Termination forVent Termination Zones Propane Venting Must Terminate END Within the Shaded AreaCo-linear Vent Installation These installation requirements must be followedMasonry or Prefabricated Chimney Conversion Horizontal Termination Snorkel Terminations„ With a 14 Snorkel „ With a 36 SnorkelHorizontal Termination Clearance Min inches, U.S. / *12 inches 30 cm canMobile Home Installation Conversion Kit ContentsTools required Regulator tower labeled for propane Regulator tower screwsFuel Conversion Procedure #33 for NG Mm for LPGBurner Plate Brass Elbow Burner OrificeAdjust the Air Shutter Gas Supply ConnectionNever USE AN Open Flame to Check for GAS Leaks High Altitude Adjustment Gas PressureLeak test Always Test Pressures with Valve Control Knob SET on HighFlame Appearance / Air Shutter Adjustment Optional Wall Thermostat or Remote ControlRemote Control FrontLog Set Installation Install Right LogSystem Check Proper pilot flame appearanceOperation Lighting of the appliance. This fog will disappear asAnnual Cleaning Glass CareVent System Burner and LogsetConnect power cord to outlet Short phillips screwdriverWingscrew Snapstat Connectors Male Quickconnector Blower OperationInstall the Rear Panel Blocking the Pilot Assembly OpeningReplace the Glass Frame Replace the Top PlateGF 400 DV Sebago Illustrated Parts Breakdown GF 400 DV Sebago Parts List Name of Installer Serial NumberDate of Purchase Purchased fromWhat to do if YOU Smell GAS Control ValvePush in gas control knob slightly and turn clockwise toOFF November 2005 137750-E Jøtul ASBox Fredrikstad Norway Jøtul North America

GF 400 DV specifications

The Jotul GF 400 DV is a highly sought-after gas stove, known for its excellent efficiency and stylish design. This innovative heating solution combines traditional aesthetics with modern technology to create a product that is not only functional but also enhances any living space.

One of the standout features of the Jotul GF 400 DV is its elegant cast iron construction. The durability of cast iron ensures that the stove retains heat longer, providing warmth even after the fire goes out. The design incorporates a large viewing window that allows for an unparalleled view of the flames, fostering a cozy atmosphere. The stove is available in several finishes, including classic black, which complements a variety of home decors.

Efficiency is a key characteristic of the GF 400 DV, as it is designed to achieve a high thermal efficiency rating. It utilizes direct venting technology, allowing for easy installation and efficient combustion. This technology facilitates the venting of exhaust gases outside the home, ensuring indoor air quality remains pristine. The adjustable heat output allows users to customize the warmth according to their needs.

Another impressive feature of the Jotul GF 400 DV is the inclusion of a variable flame adjustment system. This system enables users to control the intensity of the flames, providing both ambiance and practicality. The stove can produce up to 25,000 BTUs, making it suitable for heating medium to large spaces, with an estimated heating area of around 800 to 1,500 square feet.

The GF 400 DV is equipped with electronic ignition for hassle-free startup. Additionally, it features a remote control option, allowing users to operate the stove conveniently from a distance. The manual control option is also available for those who prefer a more traditional experience.

In terms of safety, the stove comes with built-in safety measures, including a flame failure device that automatically shuts off the gas supply if the flame goes out unexpectedly.

Overall, the Jotul GF 400 DV gas stove represents the perfect blend of traditional craftsmanship and modern efficiency. Its combination of aesthetics, innovative features, and practical heating capabilities makes it an ideal choice for homeowners looking to add warmth and character to their living spaces. Whether you’re enjoying a quiet evening at home or entertaining guests, this stove is sure to impress with its performance and beauty.