Horizontal Termination Clearance

Figure 19. Vent Terminal Clearances - National Fuel Gas Code.

A = Clearance above grade, veranda, porch , deck, or balcony : 12 inches (30 cm) minimum.

B = Clearance to window or door that may be opened:

**Min. 9 inches, U.S. / *12 inches (30 cm) CAN.

We recommend 12in. minimum to prevent condensa- tion on the window.

C = Clearance to permanently closed window:

**Min. 9 inches, U.S. / *12 inches (30 cm) CAN

We recommend 12 in. minimum to prevent condensa- tion on the window.

D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (60 cm) from the centerline of the terminal: 18 inches

(46 cm) minimum.

E = Clearance to unventilated soffit: 12 inches (46 cm) minimum.

F = Clearance to outside corner: **Min. 9 inches, U.S. / *12 inches (30 cm) CAN. We strongly recommend 12 inches, particularly where windy conditions pevail.

G = Clearance to inside corner: ** Min. 6 inches, U.S. / *12 inches (30 cm) CAN. We strongly recommend 12 inches, particularly where windy conditions pevail.

H = *Not to be installed within 15 feet (4.5 m) above a meter/regulator assembly within 3 feet (90 cm) horizontally from the center-line of the regulator.

I = Clearance to service regulator vent outlet:

3 feet (91 cm) minimum.

J = Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance:

12 inches (30 cm) minimum.

K = Clearance to a mechanical air supply inlet:

**Min. 3 feet (91 cm) above if within 10 feet horizon- tally, U.S. / *6 feet (1.83 m) minimum / CAN

L = 1 Clearance above paved sidewalk or a paved driveway located on public property: 7 feet (2.1 m) min.

M = Clearance under veranda, porch, deck, or balcony:

12 inches (30 cm) minimum. 2

*In accordance with CSA B149 Installation Codes.

**In accordance with the current ANSI Z223.1/NFFPA 54, National Fuel Gas Code. Note: Local Codes and Regulations may require different clearances.

1A vent shall not terminate directly above a sidewalk or driveway which is located between two single family dwellings and serves both dwellings.

2Only permitted if veranda, porch, deck, or balcony, is fully open on a minimum of two sides beneath the floor.*

 

21/2

12 ”

64mm

3053”

mm 76mm

Figure 20. Termination Clearance to overhangs

15

Image 15
Contents Jøtul GF 400 DV Sebago Gas Heater Welcome to Jøtul Jøtul GF 400 DV Sebago Direct Vent Gas Heater Table of ContentsGF 400 DV Sebago Specifications Suggested Tools for Installation and ServiceInput Rates Hardware Bag Contents Unpacking your stoveGlass Panel Safety Information LocationHearth Requirements Vertical Run Alcove InstallationMinimum Clearances from the Vent Pipe to Combustibles Horizontal RunExhaust Restrictor Venting RequirementsVent Restriction Intake Air RestrictorVertical Vent Termination Front LEG Back„ Minimum Vertical run must be at least 8 ft .43 m Vertical Termination for Vent Termination Zones Natural GasVenting Must Terminate END Within the Shaded Area Vent Termination Zones PropaneThese installation requirements must be followed Co-linear Vent InstallationMasonry or Prefabricated Chimney Conversion „ With a 36 Snorkel Horizontal TerminationSnorkel Terminations „ With a 14 SnorkelMin inches, U.S. / *12 inches 30 cm can Horizontal Termination ClearanceRegulator tower labeled for propane Regulator tower screws Mobile Home InstallationConversion Kit Contents Tools requiredBrass Elbow Burner Orifice Fuel Conversion Procedure#33 for NG Mm for LPG Burner PlateAdjust the Air Shutter Gas Supply ConnectionNever USE AN Open Flame to Check for GAS Leaks Always Test Pressures with Valve Control Knob SET on High High Altitude AdjustmentGas Pressure Leak testFront Flame Appearance / Air Shutter AdjustmentOptional Wall Thermostat or Remote Control Remote ControlInstall Right Log Log Set InstallationProper pilot flame appearance System CheckLighting of the appliance. This fog will disappear as OperationBurner and Logset Annual CleaningGlass Care Vent SystemShort phillips screwdriver Connect power cord to outletBlower Operation Wingscrew Snapstat Connectors Male QuickconnectorReplace the Top Plate Install the Rear PanelBlocking the Pilot Assembly Opening Replace the Glass FrameGF 400 DV Sebago Illustrated Parts Breakdown GF 400 DV Sebago Parts List Purchased from Name of InstallerSerial Number Date of PurchaseWhat to do if YOU Smell GAS Control ValvePush in gas control knob slightly and turn clockwise toOFF Jøtul North America November 2005 137750-EJøtul AS Box Fredrikstad Norway

GF 400 DV specifications

The Jotul GF 400 DV is a highly sought-after gas stove, known for its excellent efficiency and stylish design. This innovative heating solution combines traditional aesthetics with modern technology to create a product that is not only functional but also enhances any living space.

One of the standout features of the Jotul GF 400 DV is its elegant cast iron construction. The durability of cast iron ensures that the stove retains heat longer, providing warmth even after the fire goes out. The design incorporates a large viewing window that allows for an unparalleled view of the flames, fostering a cozy atmosphere. The stove is available in several finishes, including classic black, which complements a variety of home decors.

Efficiency is a key characteristic of the GF 400 DV, as it is designed to achieve a high thermal efficiency rating. It utilizes direct venting technology, allowing for easy installation and efficient combustion. This technology facilitates the venting of exhaust gases outside the home, ensuring indoor air quality remains pristine. The adjustable heat output allows users to customize the warmth according to their needs.

Another impressive feature of the Jotul GF 400 DV is the inclusion of a variable flame adjustment system. This system enables users to control the intensity of the flames, providing both ambiance and practicality. The stove can produce up to 25,000 BTUs, making it suitable for heating medium to large spaces, with an estimated heating area of around 800 to 1,500 square feet.

The GF 400 DV is equipped with electronic ignition for hassle-free startup. Additionally, it features a remote control option, allowing users to operate the stove conveniently from a distance. The manual control option is also available for those who prefer a more traditional experience.

In terms of safety, the stove comes with built-in safety measures, including a flame failure device that automatically shuts off the gas supply if the flame goes out unexpectedly.

Overall, the Jotul GF 400 DV gas stove represents the perfect blend of traditional craftsmanship and modern efficiency. Its combination of aesthetics, innovative features, and practical heating capabilities makes it an ideal choice for homeowners looking to add warmth and character to their living spaces. Whether you’re enjoying a quiet evening at home or entertaining guests, this stove is sure to impress with its performance and beauty.