System Check

1.PURGING THE GAS LINE: When lighting the appli- ance for the first time, it will take a few moments to clear the gas line of air. Once this purge is complete, the appliance will operate as described in the lighting instructions. See the inside back cover of this manual or the stove Rating Plate attached the bottom of the stove. Subsequent burner starts will not require purging the gas line unless the supply line is shut off.

2.PILOT FLAME: You can monitor the pilot flame through the view port located at the rear of the Right Log. See fig. 36. The pilot flame should be steady - not lifting or floating. The flame should be blue in color around the pilot hood, with traces of yellow toward the outer edges.

The pilot flame should engulf the top 3/8” of the thermopile (to generate millivolt current) and the top 1/8” of the thermocouple. The pilot flame should project out of the pilot hood 1” at all three ports. See fig. 37.

3.BURNER ADJUSTMENT: This stove is equipped with a variable gas control valve that allows easy adjust- ment of the flame height appearance and heat output. To adjust the flame between the HI and LOW setting, rotate the HI/LOW knob, located in the center of the valve face. Flame height will adjust approximately 1” to 2” between the LOW and HIGH settings. See fig. 38.

NO SMOKE OR SOOT SHOULD BE PRESENT. CHECK LOG PLACEMENT IF ANY SOOT OR SMOKE IS PRESENT. IF SOOT OR SMOKE PERSISTS, THE AIR SHUTTER MAY NEED TO BE ADJUSTED.

See Air Shutter/Flame Appearance section of this manual for proper air shutter settings and adjust- ments. Note: the more offsets there are in the vent system, the greater the need for an air shutter adjustment. See page 20.

WARNING:

AIR SHUTTER ADJUSTMENTS SHOULD ONLY BE PERFORMED BY A QUALIFIED PROFESSIONAL SERVICE TECHNICIAN.

 

1”

 

 

(25mm)

3/8”

1/8”

 

 

(8mm)

(3mm)

 

Min.

Min.

 

 

Figure 37. Proper pilot flame appearance.

CAUTION:

DO NOT ATTEMPT TO ALTER THE FLAME APPEARANCE BY POSITIONING THE GAS VALVE CONTROL IN ANY OTHER POSITION OTHER THAN THE FULL “ON” POSITION.

Figure 38. Flame appearance on the “high” setting after approximately 15 to 20 minutes burning.

22

Image 22
Contents Jøtul GF 400 DV Sebago Gas Heater Welcome to Jøtul Table of Contents Jøtul GF 400 DV Sebago Direct Vent Gas HeaterSuggested Tools for Installation and Service GF 400 DV Sebago SpecificationsInput Rates Unpacking your stove Hardware Bag ContentsGlass Panel Location Safety InformationHearth Requirements Horizontal Run Alcove InstallationMinimum Clearances from the Vent Pipe to Combustibles Vertical RunIntake Air Restrictor Venting RequirementsVent Restriction Exhaust RestrictorFront LEG Back Vertical Vent Termination„ Minimum Vertical run must be at least 8 ft .43 m Vent Termination Zones Natural Gas Vertical Termination forVent Termination Zones Propane Venting Must Terminate END Within the Shaded AreaCo-linear Vent Installation These installation requirements must be followedMasonry or Prefabricated Chimney Conversion „ With a 14 Snorkel Horizontal TerminationSnorkel Terminations „ With a 36 SnorkelHorizontal Termination Clearance Min inches, U.S. / *12 inches 30 cm canTools required Mobile Home InstallationConversion Kit Contents Regulator tower labeled for propane Regulator tower screwsBurner Plate Fuel Conversion Procedure#33 for NG Mm for LPG Brass Elbow Burner OrificeGas Supply Connection Adjust the Air ShutterNever USE AN Open Flame to Check for GAS Leaks Leak test High Altitude AdjustmentGas Pressure Always Test Pressures with Valve Control Knob SET on HighRemote Control Flame Appearance / Air Shutter AdjustmentOptional Wall Thermostat or Remote Control FrontLog Set Installation Install Right LogSystem Check Proper pilot flame appearanceOperation Lighting of the appliance. This fog will disappear asVent System Annual CleaningGlass Care Burner and LogsetConnect power cord to outlet Short phillips screwdriverWingscrew Snapstat Connectors Male Quickconnector Blower OperationReplace the Glass Frame Install the Rear PanelBlocking the Pilot Assembly Opening Replace the Top PlateGF 400 DV Sebago Illustrated Parts Breakdown GF 400 DV Sebago Parts List Date of Purchase Name of InstallerSerial Number Purchased fromControl Valve What to do if YOU Smell GASPush in gas control knob slightly and turn clockwise toOFF Box Fredrikstad Norway November 2005 137750-EJøtul AS Jøtul North America

GF 400 DV specifications

The Jotul GF 400 DV is a highly sought-after gas stove, known for its excellent efficiency and stylish design. This innovative heating solution combines traditional aesthetics with modern technology to create a product that is not only functional but also enhances any living space.

One of the standout features of the Jotul GF 400 DV is its elegant cast iron construction. The durability of cast iron ensures that the stove retains heat longer, providing warmth even after the fire goes out. The design incorporates a large viewing window that allows for an unparalleled view of the flames, fostering a cozy atmosphere. The stove is available in several finishes, including classic black, which complements a variety of home decors.

Efficiency is a key characteristic of the GF 400 DV, as it is designed to achieve a high thermal efficiency rating. It utilizes direct venting technology, allowing for easy installation and efficient combustion. This technology facilitates the venting of exhaust gases outside the home, ensuring indoor air quality remains pristine. The adjustable heat output allows users to customize the warmth according to their needs.

Another impressive feature of the Jotul GF 400 DV is the inclusion of a variable flame adjustment system. This system enables users to control the intensity of the flames, providing both ambiance and practicality. The stove can produce up to 25,000 BTUs, making it suitable for heating medium to large spaces, with an estimated heating area of around 800 to 1,500 square feet.

The GF 400 DV is equipped with electronic ignition for hassle-free startup. Additionally, it features a remote control option, allowing users to operate the stove conveniently from a distance. The manual control option is also available for those who prefer a more traditional experience.

In terms of safety, the stove comes with built-in safety measures, including a flame failure device that automatically shuts off the gas supply if the flame goes out unexpectedly.

Overall, the Jotul GF 400 DV gas stove represents the perfect blend of traditional craftsmanship and modern efficiency. Its combination of aesthetics, innovative features, and practical heating capabilities makes it an ideal choice for homeowners looking to add warmth and character to their living spaces. Whether you’re enjoying a quiet evening at home or entertaining guests, this stove is sure to impress with its performance and beauty.