Jotul GF 400 DV manual Mobile Home Installation, Tools required, Conversion Kit Contents

Page 16

Mobile Home Installation

Fuel Conversion

The GF 400 DV Sebago can be installed for use in a mobile home in the U.S. and Canada provided:

1.The stove is secured to the floor of the mobile home. Use Jøtul Floor Bracket Kit #154388.

2.Provision must be made to secure an electrical ground between the stove and the mobile home chassis.

3.The stove is installed in accordance with Title 24 CFR, Part 3280- Manufactured Home Construction and Safety Standard, in the U.S. In Canada, comply with CSA Z240.4, Gas Equipped Recreational Vehicles and Mobile Housing.

4.Always contact your local officials about installation restrictions and requirements in your area.

THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME, WHERE NOT PROHIBITED BY LOCAL CODES. THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS THAT IS INDICATED ON THE STOVE’S RATING PLATE. A GAS CONVERSION KIT IS PROVIDED WITH THE GF 400 SEBAGO DIRECT VENT GAS STOVE.

CET APPAREIL PEUT ETRE INSTALLE DANS UN MAISON PREFABRIQUEE (MOBILE) DEJA INSTALLEE A DEMEURE SI LES REGLEMENTS LOCAUX LE PERMETTENT. CET APPAREIL DOIT ETRE UTILISE UNIQUEMENT AVEC LES TYPES DE GAS INDIQUES SUR LA PLAQUE SIGNALETIQUE. NE PAS L’UTILISER AVEC D’AUTRES GAS SAUF SI UN KITDE CONVER- SION CERTIFIE EST INSTALLE.

The GF 400 DV Sebago gas stove is shipped from the factory equipped to burn NATURAL GAS only. If PROPANE gas is to be used as fuel, the appliance must first be converted for use with propane. Use Propane Conversion Kit 155351, supplied with the appliance.

Order and install NG Conversion Kit 155352 to change back to use with natural gas.

WARNING:

THE CONVERSION KIT IS TO BE INSTALLED BY AN AUTHORIZED JØTUL SERVICE TECHNICIAN IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTION AND ALL CODES AND REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR PROPERTY DAMAGE. THE QUALIFIED AGENCY PERFORMING THIS WORK ASSUMES RESPONSIBILITY FOR THIS CONVERSION.

IN CANADA:

THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE RE- QUIREMENTS OF THE PROVINCIAL AU- THORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIRE- MENTS OF THE CAN1-B149.1 AND .2 INSTALLATION CODE.

Tools required:

1/2” open ended wrench or deep-well socket, Torx T20 or slotted screwdriver, 4 mm allen wrench.

Conversion Kit Contents:

1, regulator tower labeled for propane

3, regulator tower screws

1, burner orifice (#33 for NG, 1.65 mm for LPG)

1, pilot orifice (#51 for NG, #30 for LPG)

Label A - to be completed and applied to

the back of the stove

Label B - apply to the stove’s Rating Plate

Small valve label - apply to valve body

Conversion instructions are also shipped in the stove with the conversion kit.

16

Image 16
Contents Jøtul GF 400 DV Sebago Gas Heater Welcome to Jøtul Table of Contents Jøtul GF 400 DV Sebago Direct Vent Gas HeaterSuggested Tools for Installation and Service GF 400 DV Sebago SpecificationsInput Rates Unpacking your stove Hardware Bag ContentsGlass Panel Location Safety InformationHearth Requirements Alcove Installation Minimum Clearances from the Vent Pipe to CombustiblesHorizontal Run Vertical RunVenting Requirements Vent RestrictionIntake Air Restrictor Exhaust RestrictorFront LEG Back Vertical Vent Termination„ Minimum Vertical run must be at least 8 ft .43 m Vent Termination Zones Natural Gas Vertical Termination forVent Termination Zones Propane Venting Must Terminate END Within the Shaded AreaCo-linear Vent Installation These installation requirements must be followedMasonry or Prefabricated Chimney Conversion Horizontal Termination Snorkel Terminations„ With a 14 Snorkel „ With a 36 SnorkelHorizontal Termination Clearance Min inches, U.S. / *12 inches 30 cm canMobile Home Installation Conversion Kit ContentsTools required Regulator tower labeled for propane Regulator tower screwsFuel Conversion Procedure #33 for NG Mm for LPGBurner Plate Brass Elbow Burner OrificeGas Supply Connection Adjust the Air ShutterNever USE AN Open Flame to Check for GAS Leaks High Altitude Adjustment Gas PressureLeak test Always Test Pressures with Valve Control Knob SET on HighFlame Appearance / Air Shutter Adjustment Optional Wall Thermostat or Remote ControlRemote Control FrontLog Set Installation Install Right LogSystem Check Proper pilot flame appearanceOperation Lighting of the appliance. This fog will disappear asAnnual Cleaning Glass CareVent System Burner and LogsetConnect power cord to outlet Short phillips screwdriverWingscrew Snapstat Connectors Male Quickconnector Blower OperationInstall the Rear Panel Blocking the Pilot Assembly OpeningReplace the Glass Frame Replace the Top PlateGF 400 DV Sebago Illustrated Parts Breakdown GF 400 DV Sebago Parts List Name of Installer Serial NumberDate of Purchase Purchased fromControl Valve What to do if YOU Smell GASPush in gas control knob slightly and turn clockwise toOFF November 2005 137750-E Jøtul ASBox Fredrikstad Norway Jøtul North America

GF 400 DV specifications

The Jotul GF 400 DV is a highly sought-after gas stove, known for its excellent efficiency and stylish design. This innovative heating solution combines traditional aesthetics with modern technology to create a product that is not only functional but also enhances any living space.

One of the standout features of the Jotul GF 400 DV is its elegant cast iron construction. The durability of cast iron ensures that the stove retains heat longer, providing warmth even after the fire goes out. The design incorporates a large viewing window that allows for an unparalleled view of the flames, fostering a cozy atmosphere. The stove is available in several finishes, including classic black, which complements a variety of home decors.

Efficiency is a key characteristic of the GF 400 DV, as it is designed to achieve a high thermal efficiency rating. It utilizes direct venting technology, allowing for easy installation and efficient combustion. This technology facilitates the venting of exhaust gases outside the home, ensuring indoor air quality remains pristine. The adjustable heat output allows users to customize the warmth according to their needs.

Another impressive feature of the Jotul GF 400 DV is the inclusion of a variable flame adjustment system. This system enables users to control the intensity of the flames, providing both ambiance and practicality. The stove can produce up to 25,000 BTUs, making it suitable for heating medium to large spaces, with an estimated heating area of around 800 to 1,500 square feet.

The GF 400 DV is equipped with electronic ignition for hassle-free startup. Additionally, it features a remote control option, allowing users to operate the stove conveniently from a distance. The manual control option is also available for those who prefer a more traditional experience.

In terms of safety, the stove comes with built-in safety measures, including a flame failure device that automatically shuts off the gas supply if the flame goes out unexpectedly.

Overall, the Jotul GF 400 DV gas stove represents the perfect blend of traditional craftsmanship and modern efficiency. Its combination of aesthetics, innovative features, and practical heating capabilities makes it an ideal choice for homeowners looking to add warmth and character to their living spaces. Whether you’re enjoying a quiet evening at home or entertaining guests, this stove is sure to impress with its performance and beauty.