Jotul GF 400 DV manual Horizontal Termination, Snorkel Terminations, „ With a 14 Snorkel

Page 14

Horizontal Termination

„Any horizontal termination must fall within the shaded portion of the vent window graph illustrated in figs. 9 or 11. For Snorkel Terminations, see below.

„Any horizontal termination except a snorkel termination, must include:

1)Minimum rise of 2 ft.

2)Minimum horizontal run of 12 in. when vertical run is less than 8 ft.

2)Maximum rise of 35 ft.

3)Maximum horizontal run of 27 ft.

4)No more than four 45° or two 90° Elbows

„Follow all termination clearance guidelines as speci- fied in fig. 19.

„The horizontal termination cap must maintain a 3" clearance to any overhead combustible projections 2 1/2" or less. It must also maintain 12" clearance from projections exceeding 2 1/2". See fig. 20.

„Wall Cut-out Opening: A minimum 10" X 10" (250 mm x 250 mm) square hole is required for proper pipe clear- ances through a combustible wall. Use a listed wall thimble for the wall penetration.

DO NOT FILL AIR SPACE WITH ANY TYPE OF INSULATION.

„Any horizontal run of vent must have a 1/4" rise for every foot of run toward the termination cap. NEVER ALLOW THE VENTING TO RUN DOWNWARD FROM STOVE TO TERMINATION; DOWNWARD VENT RUNS TRAP HEAT AND CAUSE HIGH TEMPERATURES TO DEVELOP WITHIN THE VENT THAT COULD START A FIRE.

„Install a Vinyl Siding Standoff between the vent termination and an exterior wall covered by vinyl siding material to prevent potential heat damage to the siding.

„Do not recess the termination cap into a wall or siding.

Snorkel Terminations

„THE AIR INLET RESTRICTOR MUST BE SET FULLY OPEN FOR ANY SNORKEL TERMINATION. See Fig. 6, pg. 9.

„With a 14” Snorkel:

The horizontal run made directly off the rear of the stove into a 14” snorkel cap should include no more than a single 12” straight section as shown in fig. 17. One 45° Elbow may be used for a corner installation as shown in fig. 18.

„With a 36” Snorkel:

The maximum horizontal run may be no more than 6 ft. (182 cm.)

12 in. (305 mm)

C

L

24 in.

 

Snorkel

 

(305 mm)

 

14”

 

355 mm

57”

Max.

(1448 mm)

 

12”

25

1/2

in.

Vent

Snorkel

Pipe or

(648 mm)

less

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 16.

Minimum vent for horizontal termination.

14” Maximum horizontal run directly off rear of stove with 14” Snorkel termination.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36

 

in.

 

 

Max.

 

 

Snorkel

6 ft.

 

(915 mm)

183 cm

Figure 17. Maximum Horizontal and Vertical Run with 36” Snorkel Termination.

 

Max.

45° Elbow

14”

355 mm

 

 

See Note F

 

Fig. 20

12 in. Straight Pipe

Wall Thimble

and Trim Collar

Figure 18. Corner Installation with 14” Snorkel Termination.

14

Image 14
Contents Jøtul GF 400 DV Sebago Gas Heater Welcome to Jøtul Table of Contents Jøtul GF 400 DV Sebago Direct Vent Gas HeaterInput Rates GF 400 DV Sebago SpecificationsSuggested Tools for Installation and Service Glass Panel Hardware Bag ContentsUnpacking your stove Hearth Requirements Safety InformationLocation Horizontal Run Alcove InstallationMinimum Clearances from the Vent Pipe to Combustibles Vertical RunIntake Air Restrictor Venting RequirementsVent Restriction Exhaust Restrictor„ Minimum Vertical run must be at least 8 ft .43 m Vertical Vent TerminationFront LEG Back Vent Termination Zones Natural Gas Vertical Termination forVent Termination Zones Propane Venting Must Terminate END Within the Shaded AreaCo-linear Vent Installation These installation requirements must be followedMasonry or Prefabricated Chimney Conversion „ With a 14 Snorkel Horizontal TerminationSnorkel Terminations „ With a 36 SnorkelHorizontal Termination Clearance Min inches, U.S. / *12 inches 30 cm canTools required Mobile Home InstallationConversion Kit Contents Regulator tower labeled for propane Regulator tower screwsBurner Plate Fuel Conversion Procedure#33 for NG Mm for LPG Brass Elbow Burner OrificeNever USE AN Open Flame to Check for GAS Leaks Adjust the Air ShutterGas Supply Connection Leak test High Altitude AdjustmentGas Pressure Always Test Pressures with Valve Control Knob SET on HighRemote Control Flame Appearance / Air Shutter AdjustmentOptional Wall Thermostat or Remote Control FrontLog Set Installation Install Right LogSystem Check Proper pilot flame appearanceOperation Lighting of the appliance. This fog will disappear asVent System Annual CleaningGlass Care Burner and LogsetConnect power cord to outlet Short phillips screwdriverWingscrew Snapstat Connectors Male Quickconnector Blower OperationReplace the Glass Frame Install the Rear PanelBlocking the Pilot Assembly Opening Replace the Top PlateGF 400 DV Sebago Illustrated Parts Breakdown GF 400 DV Sebago Parts List Date of Purchase Name of InstallerSerial Number Purchased fromPush in gas control knob slightly and turn clockwise toOFF What to do if YOU Smell GASControl Valve Box Fredrikstad Norway November 2005 137750-EJøtul AS Jøtul North America

GF 400 DV specifications

The Jotul GF 400 DV is a highly sought-after gas stove, known for its excellent efficiency and stylish design. This innovative heating solution combines traditional aesthetics with modern technology to create a product that is not only functional but also enhances any living space.

One of the standout features of the Jotul GF 400 DV is its elegant cast iron construction. The durability of cast iron ensures that the stove retains heat longer, providing warmth even after the fire goes out. The design incorporates a large viewing window that allows for an unparalleled view of the flames, fostering a cozy atmosphere. The stove is available in several finishes, including classic black, which complements a variety of home decors.

Efficiency is a key characteristic of the GF 400 DV, as it is designed to achieve a high thermal efficiency rating. It utilizes direct venting technology, allowing for easy installation and efficient combustion. This technology facilitates the venting of exhaust gases outside the home, ensuring indoor air quality remains pristine. The adjustable heat output allows users to customize the warmth according to their needs.

Another impressive feature of the Jotul GF 400 DV is the inclusion of a variable flame adjustment system. This system enables users to control the intensity of the flames, providing both ambiance and practicality. The stove can produce up to 25,000 BTUs, making it suitable for heating medium to large spaces, with an estimated heating area of around 800 to 1,500 square feet.

The GF 400 DV is equipped with electronic ignition for hassle-free startup. Additionally, it features a remote control option, allowing users to operate the stove conveniently from a distance. The manual control option is also available for those who prefer a more traditional experience.

In terms of safety, the stove comes with built-in safety measures, including a flame failure device that automatically shuts off the gas supply if the flame goes out unexpectedly.

Overall, the Jotul GF 400 DV gas stove represents the perfect blend of traditional craftsmanship and modern efficiency. Its combination of aesthetics, innovative features, and practical heating capabilities makes it an ideal choice for homeowners looking to add warmth and character to their living spaces. Whether you’re enjoying a quiet evening at home or entertaining guests, this stove is sure to impress with its performance and beauty.