Lennox International Inc G32Q5-100 Termination Kits, G32-100 or -125 with 3 IN. Venting, Out, Btu

Page 8

TABLE 3

TERMINATION KITS

Lennox Part

Kit LB#

Description*Inches

 

(ram)

No.

 

 

 

 

 

 

 

60G77

LB-49107CE

1-1/2" (38) Concentric

Termination

Kit

 

 

 

 

33K97

LB-87942

3" (50,8) Low Pressure Drop

Concentric Term

Kit

 

 

15F75

LB-49107CC

2"

(50,8)

Roof

 

Termination

Kit

 

 

 

 

22G44

LB-49107CD

2" (50.8)

Well

 

Assembly

Termination

Kit

 

 

15F74

LB_9107CB

2" (50.8) Walt

Ring

Kit

44J41

LB-65678A

3"

(76,2)

Roof

 

Termination

Kit

 

 

 

 

44J40

LB-65701A

3" (76.2) Wall

 

Assembly TerminationKit

 

 

30G28

WTK

2" (50.8)

Wall

 

Termination ExtendedVent

 

 

30G79

WTKX

2" (50.6)

Wall

 

Termination ExtensionRiser

 

 

When making ABS joints, pieces can be prepared with a cleaner. When joining ABS to PVC matedals, use PVC

solvent cement. Refer to this procedure as specified in ASTM D3138.

Canada Only - In some provinces, PVC primer must be purple in color, PVC solvent cement must be grey, ABS solvent cement must be yellow and PVC solvent cement used when joining ABS to PVC must be white.

[l

:: ::,::.:_::: : :: ::.::..: :.:::::::::: .::::::.::::::::::::::::.:::::::::::::::: :;:. :::_:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::.:]

Pipe used for exhaust and intake lines should be sized ac- cording to table 4. Note that maximum length of vent pipe is for one run; either intake or exhaust. Maximum vent

length given is not the total length of intake plus exhaust vents.

Each 90° elbow is equivalent to 5 feet (1.52 m) of vent pipe. Two 45° elbows are equivalent to one 90° elbow. One 45° elbow is equal to 2.5 feet (.76 m) of vent pipe.

If intake and exhaust piping runs are not equal in length and number of elbows, the larger diameter pipe must be used for both runs.

NOTE - When a WTKX terminaUon kit (30G79) is installed as part of the intake and exhaust piping, add twelve feet to the equivalent length (the two 2 inch diame- ter 90° elbows end the 27 inch pipe in the kit).

For 75 kBtuh units, connections are provided for 2 inch diameter venting which should satisfy most venting re- quirements. No transition pieces are provided or needed for 2 inch venting.

TABLE 4

VENT PIPE SIZING TABLE FOR G32Q FURNACES

MINIMUM DIAMETER OF INTAKE/EXHAUST PIPE

Vent Pipe

G32-76

G32-100

G32-125

Equivalent Length

75,000

100,000

125.000

Max. Feet (Meters)

BTU

BTU

BTU

15 (4.57

m)

2"

2"

2'

20 (6,10

m)

2"

2"

3"

25

(7.62

m)

2"

2"

3"

30 (9.14

m)

2"

3"

3_

40

 

(12.19 m)

2"

3"

3"

50

(I 5.24 m)

2"

3"

3"

55

(16.76

m)

2"

3"

3"

60

(18,29

m)

3"

3"

3"

70

(21,34

rn)

3"

3"

3"

80

(24.38

m)

3"

3"

3"

90

(27.43

m)

3"

3"

3"

100

(30.48 m)

3"

3"

3"

110

(33,53 m)

3"

3"

3"

120

(36.58 m)

3"

3"

3"

130

(39.62 m)

3"

3"

--

NOTE - Min. pipefor G32-75is 5 feet and 2 elbowsof 2 inchdmmeterp_pe. NOTE - Min. pipe for G32-100 is 5 feet end 2 elbowsof 2 inch diameter

pipe,

NOTE - Min. pipe for G32-125 is 5 feet and 2 e/bows of 2 inchdiameter pipe.

For -100and -125 kBtuh units, the intake connection is sized for 3 inch diameter pipe. The exhaust connection has a 2 inchnipple,A pipe transitionpiece is shippedwith the unitto connectto 3 inchpipe. See figure 7 for 2 inch and 3 inch venting applications.

Most venting applicationswill require 3 inch venting for proper unitoperation.For no reason should the intake

and exhaust pipe be different diameter pipes. Re- gardless of the diameter of pipe used, the standard roof and wail terminations described in Intake and Exhaust

Piping Terminations sectionshouldbe used.Exhaustpip- ingmust terminatewith 1-1/2 inchpipefor 1-1/2inchor 2 inchventing and 2 inch pipe for 3 inch venting.

G32-100 OR -125WITH 2 IN. VENTING

2 IN. VEN_]

3RIIENIXC2EIN,

2IN.

I 3IN.

OUTN

G32-100 OR -125 WITH 3 IN. VENTING

3 IN. VENT PiPE

L_I

NIPPLE,..,

OUT IN I

FIGURE 7

Page 8

Image 8
Contents Lennox TOP View AIR OutletAssembly Access Panel AIRAccess Door Interlock SwitchInches mrn Insta!iatton Setttng Equipment Shipping DamageBottom Return Filter Installation Side Return Filter Installation in.turnBottom Return Air Applications Knockout Pattern for Bottom Return AIR ApplicationSupply Air Plenum Filter Door AssemblyPiping and Fittings Specifications Termination Kits G32-100 or -125 with 3 IN. VentingOUT BTUIventingractl es Resized to approach the minimum size as deter PipeWallringkit TopviewOutsidewall Wall TerminationExhaust Termination Intake Wall RingterminationFront View Exhaust Front View ,, l/EXHAUST VentSide View ExhaarusFor Right-Hand Side Condensate Exit Nipplebootorcap AdapterUse the provided condensate drain adapter 3/4 Condensate Plumbing Groundjoint typeLeft Side Piping Right Side PipingConnections factory- and field-installed for gas leaks Precautions and ProceduresElectrostatic Discharge ESD GAS Pipe Capacity ft.3/hr Im31hrlInterior MAKE-UP BOX Installation Exterior MAKE-UP BOX InstallationHole in the cabinet. a snaphole plug is providedto G32Q and Condensing UnitG32Q Control BOX Surelight Integrated Control BoardTypical G32Q Field Wiring Diagram G32Q TWO-STAGE Control BoardTypical G32Q Schematic Wiring Diagram For Your Safety Read Before Operating Honeywell VR8205 Series GAS ValveTurn gas valve knob to on position GAS Valve Shown in OFF PositionOperation sequence followssteps 1 through4 as out Manifold Pressure Measurement & Adjustment KBtuhDIFFERENTIALPRESSURESWITCHCIRCUITRYBlower Speeds Temperature RiseAnnual Service 275F 135C Cleaning DuralokPlus TM Heat ExchangerBushing.Reconnect wires Cleaning the Bumer Assembly Reinstallthe screws to secure the burner box coverCabinet Blower PartsHeating Parts SimultaneousNormal Heating Mode Abnormal Heating ModeHeating Sequence OperationNormal Heating Mode Abnormal Indoor Blower on Delay BeginsFlame Signal GAS Valve OFF. Combustion AIRHigh Heat GAS Valve OPEN? 8 SEC. Delay Pressure Switch Watchguard Combustion AIR InducerIprepurge Combustion AIR Inducer on for 2.5 MinutesNormal Cooling Mode Abnormal Cooling Mode GPRRoOuPNEDRELYIInstaller Job NumberHeating Section TH Ermostat