Table 15: Gas Rate (CU FT/HR) at Full Input

 

 

 

 

 

Seconds For

 

Size of Test Dial

 

1 Revolution

1 Cu Ft

 

2 Cu Ft

 

5 Cu Ft

10

360

 

720

 

1800

11

327

 

655

 

1636

12

300

 

600

 

1500

13

277

 

555

 

1385

14

257

 

514

 

1286

15

240

 

480

 

1200

16

225

 

450

 

1125

17

212

 

424

 

1059

18

200

 

400

 

1000

19

189

 

379

 

947

20

180

 

360

 

900

21

171

 

343

 

857

22

164

 

327

 

818

23

157

 

313

 

783

24

150

 

300

 

750

25

144

 

288

 

720

26

138

 

277

 

692

27

133

 

267

 

667

28

129

 

257

 

643

29

124

 

248

 

621

30

120

 

240

 

600

31

116

 

232

 

581

32

113

 

225

 

563

33

109

 

218

 

545

34

106

 

212

 

529

35

103

 

206

 

514

36

100

 

200

 

500

37

97

 

195

 

486

38

95

 

189

 

474

39

92

 

185

 

462

40

90

 

180

 

450

41

88

 

176

 

439

42

86

 

172

 

429

43

84

 

167

 

419

44

82

 

164

 

409

45

80

 

160

 

400

46

78

 

157

 

391

47

76

 

153

 

383

48

75

 

150

 

375

49

73

 

147

 

367

50

72

 

144

 

360

51

71

 

141

 

355

52

69

 

138

 

346

53

68

 

136

 

340

54

67

 

133

 

333

Seconds For

 

Size of Test Dial

 

1 Revolution

1 Cu Ft

 

2 Cu Ft

 

5 Cu Ft

55

65

 

131

 

327

56

64

 

129

 

321

57

63

 

126

 

316

58

62

 

124

 

310

59

61

 

122

 

305

60

60

 

120

 

300

62

58

 

116

 

290

64

56

 

112

 

281

66

54

 

109

 

273

68

53

 

106

 

265

70

51

 

103

 

257

72

50

 

100

 

250

74

48

 

97

 

243

76

47

 

95

 

237

78

46

 

92

 

231

80

45

 

90

 

225

82

44

 

88

 

220

84

43

 

86

 

214

86

42

 

84

 

209

88

41

 

82

 

205

90

40

 

80

 

200

92

39

 

78

 

196

94

38

 

76

 

192

96

38

 

75

 

188

98

37

 

74

 

184

100

36

 

72

 

180

102

35

 

71

 

178

104

35

 

69

 

173

106

34

 

68

 

170

108

33

 

67

 

167

110

33

 

65

 

164

112

32

 

64

 

161

116

31

 

62

 

155

120

30

 

60

 

150

124

29

 

58

 

145

128

28

 

56

 

141

133

27

 

54

 

135

138

26

 

52

 

130

144

25

 

50

 

125

150

24

 

48

 

120

157

23

 

46

 

115

164

22

 

44

 

110

171

21

 

42

 

105

180

20

 

40

 

100

30

Johnson Controls Unitary Products

Image 30
Contents List of Figures Section I SafetyList of Sections List of TablesSpecific Safety Rules and Precautions Safety RequirementsCombustion AIR Quality List of Contaminants Codes and Standards InspectionDirectly BELOW. Keep Clear of ALL OBSTRUC- Tions Section II Ductwork Furnace Location and ClearancesDuctwork General Information COIL/FURNACE Assembly MC/FC/PC Series Coils Floor Base and Ductwork Installation DownflowCoil Installation Furnace Assembly MC & FC Series CoilsCoil / Furnace Assembly HC Series Coils Furnace Assembly MC Series Coils onlyFurnace Assembly PC Series Coils Coil Size Dimension C InchSuspended Furnace / Crawl Space Installation Downflow Duct Connectors Attic InstallationBottom Return and Attic Installations Horizontal ApplicationSection III Filters Filter InstallationAttempt to install filters inside the furnace Side ReturnSection IV GAS Piping Manifold Pressures in. w.c Manifold Pressures kPa Section V Electrical PowerElectrical Power Connections First Stage Manifold Pressures in. w.cAfue LOW Voltage Control Wiring ConnectionsSupply Voltage Connections LbsAC 9A TWO Stage Variable Speed Furnace OD Models AC 24C Optional HarnessID Models OD Models Humidifier Connection Accessory ConnectionsElectronic AIR Cleaner Connection TwinningCondensate Drain Termination Condensate Drain Trap and Drain Freeze ProtectionWill cause the furnace Airflow Horizontal Left Horizontal Right Inducer AS Received Combustion AIR and Vent Safety Section VII Combustion AIR and Vent SystemCombustion AIR/VENT Pipe Sizing Fitting Equivalent Length Combustion AIR and Vent Piping AssemblyCombustion AIR / Venting Furnace Vent Connection SizesVent Clearances Home LayoutVent System Vent Applications and TerminationVenting Multiple Units Combustion Air Source From Outdoors Combustion AIR SupplyOutdoor Combustion Air Ambient Combustion Air SupplyVertical Duct or Air Supply Openings and DuctsFree Area 13 cmVentilated Combustion Air Termination Specially Engineered InstallationsVentilated Combustion Air Vent Blower RotationIgnition System Sequence Section Viii START-UP AdjustmentsGAS Piping Leak Check Calculating the Furnace Input Natural GASSeconds For Size of Test Dial Revolution Cu Ft Seconds ForRevolution Cu Ft Read the manifold gas pressure Adjustment of Manifold GAS Pressure & Input RateRead the inlet gas pressure Inlet GAS Pressure RangeSection IX Safety Controls Limit Controls Sequence of OperationHot Surface Ignition System TroubleshootingFurnace Control Diagnostics Slow Green Flash Normal operationDiagnostic Fault Code Storage and Retrieval Section X Replacement Parts List Replacement Part Contact InformationDescription Section XI Wiring Diagram Johnson Controls Unitary Products York Drive Norman, OK Supersedes 438335-UIM-A-0209

TM9V MP specifications

The Johnson Controls TM9V MP is a cutting-edge variable capacity air conditioning system designed to provide optimal comfort and energy efficiency for residential and light commercial applications. This model is engineered with advanced technologies that cater to the needs of modern consumers who prioritize both performance and sustainability.

One of the standout features of the TM9V MP is its variable-speed compressor. Unlike traditional systems that operate at a fixed speed, this system can adjust its output based on the indoor temperature and humidity levels. This capability allows for precise temperature control and reduces energy consumption, ultimately leading to significant savings on utility bills. By maintaining a more consistent temperature, the TM9V MP enhances overall comfort in living spaces.

Another critical aspect of the TM9V MP is its integration of intelligent control technology. The system comes equipped with a user-friendly interface, which enables homeowners to easily monitor and adjust settings according to their preferences. Smart home integration is also a key feature, allowing for remote access and control through compatible smart devices. This ensures that users can manage their HVAC settings from anywhere, providing convenience and peace of mind.

The TM9V MP is also designed with high-efficiency ratings, often achieving SEER ratings above 18. This excellent performance not only complies with stringent energy efficiency regulations but also qualifies for various rebates and incentives in many regions, making it a financially attractive choice. The unit’s environmentally friendly refrigerant further emphasizes its commitment to sustainability.

In terms of construction and durability, the TM9V MP boasts a rugged design with high-quality components. Its enhanced sound insulation minimizes operational noise, making it suitable for residential settings where quiet operation is essential. The unit is also designed for easy installation and maintenance, which can further reduce lifecycle costs.

Overall, the Johnson Controls TM9V MP represents a blend of advanced engineering, energy efficiency, and user-friendly technology. Its variable speed compressor, smart controls, high-efficiency ratings, and durable construction make it a top choice for anyone seeking an HVAC solution that meets modern comfort and sustainability standards. With the TM9V MP, users can enjoy the benefits of a comfortable indoor environment while contributing to a greener future.