Bryant 310AAV instruction manual Gas Rate cu ft./hr, Filter Size Information In. / mm

Page 38

310AAV

Table 13—Gas Rate (cu ft./hr)

SECONDS FOR 1

SIZE OF TEST DIAL

SECONDS FOR 1

SIZE OF TEST DIAL

 

 

 

 

 

 

REVOLUTION

1 Cu Ft

2 Cu Ft

5 Cu Ft

REVOLUTION

1 Cu Ft

2 Cu Ft

5 Cu Ft

 

 

 

 

 

 

 

 

10

360

720

1800

50

72

144

360

11

327

655

1636

51

71

141

355

12

300

600

1500

52

69

138

346

13

277

555

1385

53

68

136

340

14

257

514

1286

54

67

133

333

15

240

480

1200

55

65

131

327

16

225

450

1125

56

64

129

321

17

212

424

1059

57

63

126

316

18

200

400

1000

58

62

124

310

19

189

379

947

59

61

122

305

20

180

360

900

60

60

120

300

21

171

343

857

62

58

116

290

22

164

327

818

64

56

112

281

23

157

313

783

66

54

109

273

24

150

300

750

68

53

106

265

25

144

288

720

70

51

103

257

26

138

277

692

72

50

100

250

27

133

267

667

74

48

97

243

28

129

257

643

76

47

95

237

29

124

248

621

78

46

92

231

30

120

240

600

80

45

90

225

31

116

232

581

82

44

88

220

32

113

225

563

84

43

86

214

33

109

218

545

86

42

84

209

34

106

212

529

88

41

82

205

35

103

206

514

90

40

80

200

36

100

200

500

92

39

78

196

37

97

195

486

94

38

76

192

38

95

189

474

96

38

75

188

39

92

185

462

98

37

74

184

40

90

180

450

100

36

72

180

41

88

176

439

102

35

71

178

42

86

172

429

104

35

69

173

43

84

167

419

106

34

68

170

44

82

164

409

108

33

67

167

45

80

160

400

110

33

65

164

46

78

157

391

112

32

64

161

47

76

153

383

116

31

62

155

48

75

150

375

120

30

60

150

49

73

147

367

 

 

 

 

Table 14—Filter Size Information (In. / mm)

 

 

FILTER SIZE

 

FURNACE CASING WIDTH

 

 

 

FILTER TYPE

SIDE

 

BOTTOM

 

RETURN

 

RETURN

 

14---1/2 (368)

16 x25 x3/4

 

14 x25 x3/4

Washable*

(406 x635 x19)

 

(356 x635 x19)

 

 

 

 

 

 

 

 

17---1/2 (445)

16 x25 x3/4

 

16 x25 x3/4

Washable*

(406 x635 x19)

 

(406 x635 x19)

 

 

 

 

 

 

 

 

21 (533)

16 x25 x3/4

 

20 x25 x3/4

Washable*

(406 x635 x19)

 

(508 x635 x19)

 

 

 

 

 

 

 

 

24 (610)

16 x25 x3/4

 

24 x25 x3/4

Washable*

(406 x635 x19)

 

(610 x635 x19)

 

 

 

 

 

 

 

 

* Recommended

 

 

 

 

** Some furnaces may have 2 filters.

 

 

 

 

38

Image 38
Contents 310AAV/JAV CUT Hazard Safety ConsiderationsFurnace Reliability Hazard Inlet Width Size 20/060155Codes and Standards SafetyIntroduction Electrostatic Discharge ESD Precautions Procedure LocationMultipoise Orientations Fire and Explosion HazardFire Hazard AIR for Combustion VentilationPersonal Injury AND/OR Property Damage Hazard Location Relative to Cooling EquipmentCarbon Monoxide Poisoning Hazard Outdoor Combustion Air MethodOther than FAN-ASSISTED Total Bottom Return Air Inlet InstallationUpflow Installation Side Return Air InletDownflow Installation Leveling Legs Leveling Legs If DesiredRoll-Out Protection Suspended Furnace SupportPlatform Furnace Support Filter Arrangement Carbon Monoxide and Poisoning HazardGeneral Requirements Opening Dimensions In. mmAIR Ducts Ductwork Acoustical Treatment Supply Air ConnectionsSize Inlet Air Delivery CFM with FilterFurnace RETURN---AIR Speed ⎯ Air Delivery CFM with Filter FurnaceHorizontal Unit Suspension Typical Attic Installation Downflow Return Air Configurations and Restrictions Maximum Capacity of Pipe Return Air ConnectionsGAS Piping Fire or Explosion Hazard Furnace Overheat HazardBurner and Manifold Electrical Connections Electrical Shock HazardFurnace MAY not Operate WiringElectrical Shock and Fire Hazard BOX RelocationElectrical Data Power Cord Installation in Furnace J-BOXBX Cable Installation in Furnace J-BOX Furnace Control General Venting Requirements AccessoriesVenting Masonry Chimney Requirements Chimney Inspection Chart Burn Hazard Appliance Application RequirementsAdditional Venting Requirements Sidewall VentingInternal Area of Chimney Vent HeightUpflow Application-Vent Elbow Up Diameter Height Orientation Input BTUH/HRDownflow Application-Vent Elbow Up then Left Horizontal Right Application-Vent Elbow Right Adjustments START-UP, ADJUSTMENT, and Safety CheckStart-Up Procedures GeneralFurnace Damage Hazard Never Assume Orifice SIZE. Always Check and VerifySpeed Selection Furnace Overheating HazardWiring Diagram Gas Control Valve Orifice Hole Check Safety Controls ChecklistSeconds for Size of Test Dial Revolution Gas Rate cu ft./hrFilter Size Information In. / mm Specific Gravity of Natural GAS Altitude Range BTU/CU FTSpecific Gravity of Natural GAS Altitude Range Heat Value AT Altitude Specific Gravity of Natural GAS AltitudeService and Maintenance Procedures IntroductionCarbon Monoxide Poisoning and Fire Hazard Care and MaintenanceCleaning AND/OR Replacing AIR Filter Unit Damage Hazard Media cabinet filter proceduresBlower Motor and Wheel Electrical Shock Hazard Cleaning Heat Exchanger Igniter Position-Side ViewSequence of Operation HeatingCooling Mode Wiring DiagramsTroubleshooting Continuous Blower ModeTroubleshooting Guide Chimneyin KitAdapter VentBlocked usedswitch Accessory List Description Part NumberParts Replacement Information Guide
Related manuals
Manual 45 pages 34.04 Kb

310AAV specifications

The Bryant 310AAV and 310JAV are high-efficiency air conditioning and heating systems designed for residential and light commercial applications. These models embody Bryant's commitment to delivering reliable comfort solutions while prioritizing energy efficiency and performance.

One of the standout features of the Bryant 310AAV and 310JAV is their impressive Seasonal Energy Efficiency Ratio (SEER) ratings. The higher the SEER, the more efficient the unit is in using electricity to cool your space. The Bryant 310AAV boasts a SEER rating of up to 16, while the 310JAV offers a slightly lower rating. This efficiency translates into cost savings on monthly energy bills while ensuring indoor comfort throughout the year.

Both models utilize advanced technologies, including two-stage heating and cooling capabilities. This means that the systems can adjust their operation based on the heating or cooling needs of a space, providing optimal temperature control while reducing energy waste. The two-stage operation also contributes to quieter operation levels, making these units suitable for residential settings where noise is a concern.

The 310AAV and 310JAV are equipped with variable-speed compressors, which further enhance their efficiency and comfort levels. The variable-speed technology allows the system to operate at different speeds, ensuring consistent temperature management and reducing the frequency of on-and-off cycling. This leads to steadier indoor temperatures and improved humidity control.

In addition to their performance features, Bryant places a strong emphasis on durability and dependability. The units are constructed with high-quality materials that are designed to withstand various environmental conditions. Features such as a weather-resistant cabinet and an efficient coil design help protect the units from wear and tear, ensuring long-lasting performance.

The implementation of environmentally friendly refrigerant options is another characteristic that demonstrates Bryant's commitment to sustainability. Both the 310AAV and 310JAV utilize R-410A refrigerant, which has a lower environmental impact compared to older refrigerants, aligning with modern standards for eco-friendly HVAC systems.

Overall, the Bryant 310AAV and 310JAV represent a blend of efficiency, advanced technology, and durability. With their attractive SEER ratings, two-stage operation, variable-speed capabilities, and commitment to sustainability, these models stand out as excellent choices for homeowners and businesses looking to enhance their heating and cooling solutions while keeping energy consumption in check. Whether for residential comfort or light commercial use, these Bryant units promise reliability and performance for years to come.