Bryant 310AAV instruction manual Accessory List, Description Part Number

Page 51

Table 17—Accessory List

DESCRIPTION

PART NUMBER

NOTES

 

 

 

 

FILCABXX0016

Filter cabinet 16” (406 mm) for 4” (102 mm) wide filter

 

 

 

Media Filter Cabinet

FILCABXX0020

Filter cabinet 20” (508 mm) for 4” (102 mm) wide filter

 

 

 

 

FILCABXX0024

Filter cabinet 24” (610 mm) for 4” (102 mm) wide filter

 

 

 

 

FILXXCAR0016

Filter Cartridge replacements for FILCAB media cabinet

 

 

 

Cartridge Media Filter

FILXXCAR0020

Filter Cartridge replacements for FILCAB media cabinet

 

 

 

 

FILXXCAR0024

Filter Cartridge replacements for FILCAB media cabinet

 

 

 

 

EXPXXUNV0016

16” (406 mm) Replacement Expandable Filter assembly

 

 

 

EZ Flex Media Filter with End Caps

EXPXXUNV0020

20” (508 mm) Replacement Expandable Filter assembly

 

 

 

 

EXPXXUNV0024

24” (610 mm) Replacement Expandable Filter assembly

 

 

 

 

EXPXXFIL0016

16” (406 mm) Replacement filter for EXPUNV assembly

 

 

 

Replacement EZ Flex Filter Media

EXPXXFIL0020

20” (508 mm) Replacement filter for EXPUNV assembly

 

 

 

 

EXPXXFIL0024

24” (610 mm) Replacement filter for EXPUNV assembly

 

 

 

 

KGAFR0401B14

Bottom return filter rack 14” (356 mm) casing

 

 

 

External Bottom Return Filter Rack

KGAFR0501B17

Bottom return filter rack 17” (432 mm) casing

 

 

KGAFR0601B21

Bottom return filter rack 21” (533 mm) casing

 

 

 

 

 

KGAFR0701B24

Bottom return filter rack 24” (610 mm) casing

 

 

 

External Side Return Filter Rack

KGAFR0801SRE

Ext. Side filter rack--- all casings--- includes filter

 

 

 

 

KGAWF1301UFR†

(1) unframed filter 16x25x3/4 (406x635x19 mm)

 

 

 

 

KGAWF1401UFR

(1) unframed filter 20x25x3/4 (508x635x19 mm)

 

 

 

Unframed Filter 3/4--- in. (19 mm)

KGAWF1501UFR

(1) unframed filter 24x25x3/4 (610x635x19 mm)

 

 

KGAWF1306UFR†

(6) unframed filter 16x25x3/4 (406x635x19 mm)

 

 

 

 

 

KGAWF1406UFR

(6) unframed filter 20x25x3/4 (508x635x19 mm)

 

 

 

 

KGAWF1506UFR

(6) unframed filter 24x25x3/4 (610x635x19 mm)

 

 

 

Flue Extension

KGAFE0112UPH

(12) vent extension 4” (102 mm) dia. x 3--- 1/2” (89 mm)

 

 

 

*Twinning Kit

KGATW0601HSI

Single or two stage PSC equipped units only

 

 

 

Combustible Floor Base

KGASB0201ALL

Adjustable floor base --- fits all casing sizes

 

 

 

Downflow Vent Guard

KGBVG0101DFG

Vent flue shield --- downflow venting outside casing

 

 

 

Vent Extension Kit

KGAVE0101DNH

Downflow, through casing vent extension

 

 

 

Chimney Adapter Kit

KGACA02014FC

Masonry chimney adapter 4” (102 mm)

 

 

KGACA02015FC

Masonry chimney adapter 5” (127 mm)

 

 

 

 

Natural--- to--- Propane Conversion Kit

KGANP4601ALL

Gas conversion natural to propane all

 

 

 

Propane--- to--- Natural Conversion Kit

KGAPN3901ALL

Gas conversion propane to natural all

 

 

 

Label Kit

KGALB0101KIT

Downflow orientation label replacement

 

 

 

**ECM Motor Simulator

KGASD0301FMS

ECM blower and inducer simulator --- variable speed units

 

 

 

**Advanced Product Monitor

KGAFP0301APM

PC software and hardware for Troubleshooting variable speed units

*Not for ECM or variable---speed ECM models

**Variable---speed ECM models only

310AAV

51

Image 51
Contents 310AAV/JAV Safety Considerations Furnace Reliability HazardCUT Hazard 20/060155 Inlet Width SizeSafety IntroductionCodes and Standards Location Electrostatic Discharge ESD Precautions ProcedureFire and Explosion Hazard Multipoise OrientationsLocation Relative to Cooling Equipment AIR for Combustion VentilationPersonal Injury AND/OR Property Damage Hazard Fire HazardOutdoor Combustion Air Method Carbon Monoxide Poisoning HazardOther than FAN-ASSISTED Total Side Return Air Inlet InstallationUpflow Installation Bottom Return Air InletLeveling Legs Leveling Legs If Desired Downflow InstallationFilter Arrangement Carbon Monoxide and Poisoning Hazard Suspended Furnace SupportPlatform Furnace Support Roll-Out ProtectionDuctwork Acoustical Treatment Supply Air Connections Opening Dimensions In. mmAIR Ducts General RequirementsAir Delivery CFM with Filter Furnace RETURN---AIR SpeedSize Inlet Furnace ⎯ Air Delivery CFM with FilterHorizontal Unit Suspension Typical Attic Installation Downflow Return Air Configurations and Restrictions Furnace Overheat Hazard Return Air ConnectionsGAS Piping Fire or Explosion Hazard Maximum Capacity of PipeElectrical Connections Electrical Shock Hazard Burner and ManifoldBOX Relocation WiringElectrical Shock and Fire Hazard Furnace MAY not OperatePower Cord Installation in Furnace J-BOX BX Cable Installation in Furnace J-BOXElectrical Data Furnace Control Accessories VentingGeneral Venting Requirements Masonry Chimney Requirements Chimney Inspection Chart Sidewall Venting Appliance Application RequirementsAdditional Venting Requirements Burn HazardVent Height Internal Area of ChimneyDiameter Height Orientation Input BTUH/HR Upflow Application-Vent Elbow UpDownflow Application-Vent Elbow Up then Left Horizontal Right Application-Vent Elbow Right General START-UP, ADJUSTMENT, and Safety CheckStart-Up Procedures AdjustmentsNever Assume Orifice SIZE. Always Check and Verify Furnace Damage HazardFurnace Overheating Hazard Speed SelectionWiring Diagram Gas Control Valve Orifice Hole Checklist Check Safety ControlsGas Rate cu ft./hr Filter Size Information In. / mmSeconds for Size of Test Dial Revolution BTU/CU FT Specific Gravity of Natural GAS Altitude RangeSpecific Gravity of Natural GAS Altitude Range Heat Value AT Altitude Altitude Specific Gravity of Natural GASIntroduction Service and Maintenance ProceduresCare and Maintenance Cleaning AND/OR Replacing AIR FilterCarbon Monoxide Poisoning and Fire Hazard Media cabinet filter procedures Blower Motor and Wheel Electrical Shock HazardUnit Damage Hazard Igniter Position-Side View Cleaning Heat ExchangerHeating Sequence of OperationContinuous Blower Mode Wiring DiagramsTroubleshooting Cooling ModeTroubleshooting Guide Chimneyin KitAdapter VentBlocked usedswitch Description Part Number Accessory ListParts Replacement Information Guide
Related manuals
Manual 45 pages 34.04 Kb

310AAV specifications

The Bryant 310AAV and 310JAV are high-efficiency air conditioning and heating systems designed for residential and light commercial applications. These models embody Bryant's commitment to delivering reliable comfort solutions while prioritizing energy efficiency and performance.

One of the standout features of the Bryant 310AAV and 310JAV is their impressive Seasonal Energy Efficiency Ratio (SEER) ratings. The higher the SEER, the more efficient the unit is in using electricity to cool your space. The Bryant 310AAV boasts a SEER rating of up to 16, while the 310JAV offers a slightly lower rating. This efficiency translates into cost savings on monthly energy bills while ensuring indoor comfort throughout the year.

Both models utilize advanced technologies, including two-stage heating and cooling capabilities. This means that the systems can adjust their operation based on the heating or cooling needs of a space, providing optimal temperature control while reducing energy waste. The two-stage operation also contributes to quieter operation levels, making these units suitable for residential settings where noise is a concern.

The 310AAV and 310JAV are equipped with variable-speed compressors, which further enhance their efficiency and comfort levels. The variable-speed technology allows the system to operate at different speeds, ensuring consistent temperature management and reducing the frequency of on-and-off cycling. This leads to steadier indoor temperatures and improved humidity control.

In addition to their performance features, Bryant places a strong emphasis on durability and dependability. The units are constructed with high-quality materials that are designed to withstand various environmental conditions. Features such as a weather-resistant cabinet and an efficient coil design help protect the units from wear and tear, ensuring long-lasting performance.

The implementation of environmentally friendly refrigerant options is another characteristic that demonstrates Bryant's commitment to sustainability. Both the 310AAV and 310JAV utilize R-410A refrigerant, which has a lower environmental impact compared to older refrigerants, aligning with modern standards for eco-friendly HVAC systems.

Overall, the Bryant 310AAV and 310JAV represent a blend of efficiency, advanced technology, and durability. With their attractive SEER ratings, two-stage operation, variable-speed capabilities, and commitment to sustainability, these models stand out as excellent choices for homeowners and businesses looking to enhance their heating and cooling solutions while keeping energy consumption in check. Whether for residential comfort or light commercial use, these Bryant units promise reliability and performance for years to come.