Trane RT-PRC010-EN manual 1 1 567

Page 21

Model

Number

Description

S

X H

G D 1 1 4

O A

H 7

C F

9

D

3

0

0

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

02

1

2

3

4

567

8

9

10

11 12

13 14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

DIGIT 1 — UNIT TYPE

S = Self-Contained (Packaged Rooftop)

DIGIT 2 — UNIT FUNCTION

E= DX Cooling, Electric Heat

F= DX Cooling, Natural Gas Heat

L= DX Cooling, Hot Water Heat

S= DX Cooling, Steam Heat

X= DX Cooling, No Heat, Extended Casing

DIGIT 3 — UNIT AIRFLOW

H = Single Zone

DIGIT 4 — DEVELOPMENT SEQUENCE

G = Seventh

DIGITS 5,6,7 — NOMINAL CAPACITY

C90 = 90 Tons

D11 = 105 Tons

D12 = 115 Tons

D13 = 130 Tons

DIGIT 8 — POWER SUPPLY

4= 460/60/3 XL

5= 575/60/3 XL E = 200/60/3 XL F = 230/60/3 XL

DIGIT 9 — HEATING CAPACITY

0 = No Heat

H = High Heat - 2-Stage

J= High Heat - Limited Modulation P = High Heat - Full Modulation

Note:

When the second digit calls for “E” (electric heat), the following values apply in the ninth digit:

W = 190 KW

When the second digit calls for ‘’L’’ or ‘’S’’, one of the following valve size values must be in Digit 9:

High Heat Coil: 3 = 1.0”, 4 = 1.25”, 5 = 1.50”, 6 = 2.0”, 7 = 2.5”

Low Heat Coil: C = 1.0”, D = 1.25”, E = 1.50”, F = 2.0”, G = 2.5”

DIGIT 10 — DESIGN SEQUENCE

A = First (Factory Assigned)

Note: Sequence may be any letter A thru Z, or any digit 1 thru 9.

DIGIT 11 — EXHAUST OPTION

0 = None

7 = 100%, 15 HP W/Statitrac

8= 100%, 20 HP W/Statitrac

9= 100%, 25 HP W/Statitrac F = 50%, 15 HP

H = 100%, 30 HP W/Statitrac J = 100%, 40 HP W/Statitrac

K = 100%, 15 HP W/O Statitrac (CV Only) L = 100%, 20 HP W/O Statitrac (CV Only) M = 100%, 25 HP W/O Statitrac (CV Only) N = 100%, 30 HP W/O Statitrac (CV Only) P = 100%, 40 HP W/O Statitrac (CV Only)

DIGIT 12 — EXHAUST AIR FAN DRIVE

0 = None

5= 500 RPM

6= 600 RPM

7= 700 RPM

8= 800 RPM

DIGIT 13 — FILTER

A = Throwaway

C = High-Efficiency Throwaway

D= Bag With Prefilter

E= Cartridge With Prefilter

F= Throwaway Filter Rack Less Filter Media

G= Bag Filter Rack Less Filter Media

DIGIT 14 — SUPPLY AIR FAN HP

C= 30 HP (2-15 HP)

D= 40 HP (2-20 HP)

E= 50 HP (2-25 HP)

F= 60 HP (2-30 HP)

G= 80 HP (2-40 HP)

DIGIT 15 — SUPPLY AIR FAN DRIVE 9 = 900 RPM

A = 1000 RPM

B = 1100 RPM

C= 1200 RPM

D= 1300 RPM

E = 1400 RPM

F = 1500 RPM

G= 1600 RPM

DIGIT 16 — FRESH AIR

D = 0-100% Economizer (Std.)

DIGIT 17 — SYSTEM CONTROL

1= Constant Volume Control

2= VAV Supply Air Temperature Control w/o Inlet Guide Vanes

3= VAV Supply Air Temperature Control w/ Inlet Guide Vanes

4= Space Pressure Control with Exhaust VFD w/o Bypass

5= Space Pressure Control with Exhaust VFD and Bypass

6= VAV Supply Air Temperature Control with VFD w/o Bypass

7= VAV Supply Air Temperature Control with VFD and Bypass

8= Supply and Exhaust Fan with VFD w/o Bypass

9= Supply and Exhaust Fan with VFD and Bypass

DIGIT 18 — ACCESSORY PANEL

0 = None

A = BAYSENS008*

B = BAYSENS010*

C = BAYSENS013*

D = BAYSENS014*

E = BAYSENS019*

F= BAYSENS020*

G= BAYSENS021*

DIGIT 19 — AMBIENT CONTROL

0 = Standard

DIGIT 20 — AGENCY APPROVAL

0= None (UL Gas Heater, see note)

1= UL

2= CSA

Note: Includes UL classified gas heating section only, when second digit of Model No. is a “F.”

DIGITS 21 - 36 — MISCELLANEOUS

21A = Unit Disconnect Switch

22B = Hot Gas Bypass (CV Only)

23D = Economizer Control w/ Comparative Enthalpy

23R = Economizer Control w/ Reference Enthalpy

23T = Economizer Control w/Dry Bulb

24E = Low Leak Fresh Air Dampers

25F = High Duct Temperature Thermostat

26G = High Capacity Evaporator

Coil (90-105 Only)

27

K

= Generic B.A.S. Module

28

L

=

High-Efficiency Motors

 

 

 

(Supply and Exhaust)

29

M

= Remote Human Interface

30

N

=

Ventilation Override Module

31

R

= Extended Grease Lines

32

T

= Access Doors

1.EXAMPLE: Model numbers: SFHFC55FHA55C69D3001N describes a unit with the following characteristics: DX cooling with natural gas heating, 55 ton nominal cooling capacity, 230/60/3 power supply, high heat model. 100 percent exhaust with Statitrac, 7.5 HP exhaust fan motor with drive selection No. 5 (500 RPM), high-efficiency throwaway filters, 20 HP supply fan motor with drive selection No. 9 (900 RPM), 0-100% economizer, VAV supply air temperature control with inlet guide vanes, no remote panel, standard ambient control, U.L. agency approval. The service digit for each model number contains 38 digits; all 38 digits must be referenced.

2.EXAMPLE: Model numbers: SXHGD1140AH7CF8D3001 describes a unit with the following characteristics: DX cooling with extended casing, no heat, 105 ton nominal cooling capacity, 460/60/3 power supply, no heat, 100 percent exhaust with Statitrac, 30 h.p. exhaust fan motor with drive selection No. 7 — (700 RPM), high-efficiency throwaway filters, 60 hp supply fan motor with drive selection No. 8 — (900 RPM), economizer, VAV supply air temperature control with inlet guide vanes, no remote panel, standard ambient, UL agency approval. The service digit for each model number contains 36 digits; all 36 digits must be referenced.

3.Available as standard 460 volt only for 70 and 75 ton models.

33

V

= Inter-Processor

 

 

Communication Bridge

34

Y

= Trane Communication

 

 

Interface Module

35

5

= VFD Line Reactor

36

6

= Factory-Powered 15A GFI

 

 

Convenience Outlet

RT-PRC010-EN

21

Image 21
Contents 20 75Tons 90 130Tons American Standard Inc IntroductionContents Standard Features Features and BenefitsOptional Features Field Installed AccessoriesInstallation Ease Features SummaryEasy to Service ReliabilityIntegrated Comfort System ICS SimplifyingThe Comfort SystemTracer control points for IntelliPak Rooftops Features and Benefits Optimum Building Comfort Control FansWith Inlet GuideVanesVariable Frequency Drives VFD Trane 3-DScroll Compressor Proven DesignThroughTesting and ResearchSimple Design with 70% Fewer Parts LowTorqueVariationApplication Considerations Barometric Relief Dampers Percent Exhaust SystemHorizontal Discharge Panel C Dimensions20 75 tons SXHF, SFHF, SLHF, SSHF, SXHF, SFHF, SLHF, Sshf UnitsTable AC-4 SXHG, SLHG, Sshg Panel a and B Dimensions Table AC-5 SXHG, SLHG, Sshg Z Dimensions2508 17.4 Corrosive Atmospheres High Capacity Evaporator CoilVentilation Override Sequences Natural Gas Heating ConsiderationsClearance Requirements Acoustical ConsiderationsDuct Design Figure AC-4 Unit PlacementSelection Procedure Electric Heating System DetermineTotalWinter Heating LoadGas Heating System Natural Gas HotWater HeatingSupply Fan Motor Sizing Exhaust Fan Motor SizingAltitude Corrections Selection Procedure H F C Model Number Description1 1 567 Table GD-1- General Data 20-40Tons General Data20Ton 25Ton 30Ton 40Ton RPMFilters Table GD-2 General Data 50-75Tons Low Ambient Option Min. Outside AirTemp 50Ton 55Ton 60Ton 70Ton 75TonTable GD-3 General Data 90-130Tons 90Ton 105Ton 115Ton 130Ton50% 100% Number/Size/Type 22/FC Table GD-4 ARI Performance Data Table GD-5 ARI Correction MultipliersEER Iplv Table PAF-1 Enthalpy of Saturated AIR Performance Adjustment FactorsPerformance 20Ton Data Performance 25Ton Data Performance 30Ton Data 345 452 265 496 183 Performance 40Ton Data561 207 451 399 493 302 537 199 429 389 468 292 431 551Performance 50Ton Data Performance 55Ton Data Performance 60Ton Data AmbientTemperature F Performance 70Ton DataFlow Performance 75Ton Data Performance 90Ton Data Performance 105Ton Data 115, 130Tons PerformanceTable PD-24 Natural Gas Heating Capacities Performance DataTable PD-25- Natural Gas Heating Capacities Table PD-26 Steam Heating Capacities Q/ITD1Table PD-28 20 to 75-Tons Electric Heat AirTemperature Rise Table PD-29- 90To 130-Ton Electric Heat AirTemperature RiseTable PD-30- Electric Heat KW Ranges Table PD-31- HotWater Heating Capacities Q/ITD1 RPM BHP 20, 25TonsPressure 1225 1271 4000 10371364 140910 HP 1200 RPM 80% 1100 RPM 22.22 6000 883 927 968 1007 1043 10781400 RPM Wocfm 40% 1300 RPM 25 HP Inches 1200 RPM 50% 20 HP Table PD-35 Supply Fan PerformanceWITH Inletvanes 30Ton 6000 890 933 974 1012 10491357 20.45 Ithout Exhaust Dual 18 X 18 Fans Wocfm Entrance Losses15 HP 1200 RPM Fan Curve Limits 1000 RPM 10 HP40, 50, 55Tons 30.4732.36 40, 50, 55Tons 1161 32.63 Cfm Total Static Pressure Std 250 500 750 000 800 14.86 820Inches w.c 43.85 60, 70, 75Tons60, 70, 75Tons 14000 729 800 RPM 20 HP 70% 15 HP 904 13.34 28000 667 710 750 791 826 10.15 857 27000 646 690 732 773 808 840 10.71 87230000 708 749 787 826 10.13 861 897 12.88 928 14.40 957 15.80 98529000 1375 42.04 1398 43.93 1423 45.91 1445 27000 1363 39.85 1388 41.68 1414 43.54 1437 45.26 14611469 49.80 1491 1515 53.66 30000 1382 43.16 1406 45.18 1428904 13.44 935 14.77 28000 718 756 791 825 10.28 858 27000 695 734 770 805 840891 12.90 922 14.26 952 15.65 29000 741 778 812 845 897 13.19 928 14.59 958 16.05 98732000 1442 49.55 1464 15791496 55.23 1518 57.33 1541 59.53 1565 37000 1494Performance 105,115,130Tons 00 R 1500 1623 76.74 1640 78.951100 100 900 RP26.95 25.3532.56 1233 34.40 1255 36.26 1277 38.17 46000 1138 26.67 30.40 1216 32.05 1240 33.79 1086 23.371641 79.40 1625 76.92 1643 79.30 46000 1624Performance 20 -75Tons Data Table PD-44 Component Static Pressure Drops in.W.GSFHF/G SEHF/G SLHF/G SSHF/G Table PD-45 Component Static Pressure Drops in.W.G Performance 90-130Tons DataSFHF/G SLHF/G SSHF/GTable PD-47 90-130 -Tons Supply Air Fan Drive Selections Table PD-46 20-75 -Tons Supply Air Fan Drive SelectionsBHP RPM 835 39.71 859885 44.08 910 46.33 934 48.32 Table PD-51 90-130Tons -100% Exhaust Fan Drive Selections Table PD-50 20-75Tons 100% Exhaust Fan Drive SelectionsTable PD-52 20-75Tons 50% Exhaust Fan Performance Table PD-53 90-130 Tons 50% Exhaust Fan Performance18.97 835 19.86 859 20.87 885 22.05 910 23.18 934 24.17 Table PD-54- 50% Exhaust Fan Drive Selections Controls VAV UnitsVAV Units Only Reset based on outdoor air temperature Supply Air Setpoint ResetReset based on zone temperature ZoneTemperature Control Unoccupied Zone Heating and CoolingCV Units CV Units OnlyHeating Gas Heating -Two-Stage Gas Heating Modulating Gas Unoccupied ZoneTemperature Control Cooling and HeatingElectric Heating HotWater or Steam HeatingVAV/CV Units Purge sequence D Exhaust sequence CPurge with duct pressure control E Human Interface Panel H.IHuman Interface Panel Main Menu Generic Building Automation System odule GbasEvaporator Coil Frost Protection Dry BulbTemperature Control of Economizer Occupied/Unoccupied SwitchingNight Setback Sensors Occupied/Unoccupied input on the RTMDual Source Power units 200V Electrical Service SizingElectrical Data Set 2. Rooftop units with Electric Heat178 21.8 143 RLA1 LRA48.5 39.0 Motor Hp Table ED-6 -Voltage Utilization Range48.5 39.0 FLADimensional 20 75Tons Detail B Covers 40, 60, 70 and 75 TON Units Figure DD-1 20-75Ton Cooling Only Unit Dimensions Sahf20 & 25 5-8 15/ 16 24-1 3 5/ 8 1-7 9 10’-1 7 ’-10 15/ 16 2’-0 ’-6 SahfFigure DD-5 90 130Tons Service Clearance Dimensional 90 130TonsSection B-B RT-PRC010-EN Figure DD-6 90 130Ton Roof Curb DimensionsField Installed Sensors DimensionalConstant Integrated Comfort System Sensors CV and VAVTableW-1 -Approximate OperatingWeights Lbs./Kg WeightsSL/SS 14740 15380 15930 16080Options OptionsAmbient Control Agency ApprovalMiscellaneous Options Roof Curb Electronic Zone SensorsGeneral Mechanical Specifications90 130Ton Units Supply Fan 20 75Ton UnitsControls Unit ControllerHigh efficiency throwaway option Permanent cleanable wire mesh optionPercent bag filter option Percent cartridge filter optionManual outside air option Outside Air GeneralPercent modulating economizer option Ultra low-leak economizer dampers optionHeating System AccessoriesLiterature Order Number File Number PL-RT-S*HF/S*HG-20-130TONS-PRC0010-EN-10-2001Supersedes RT-DS-8 05/98 Stocking Location Inland-LaCrosse

RT-PRC010-EN specifications

The Trane RT-PRC010-EN is a prominent model in the line of Trane's packaged rooftop units, designed to offer efficient heating, cooling, and ventilation for commercial applications. Renowned for its robust performance, this unit integrates advanced technologies and superior engineering to meet diverse environmental needs while ensuring energy efficiency and reliability.

One of the key features of the RT-PRC010-EN is its energy-efficient operation. The unit is equipped with variable-speed fans and scroll compressors, which allow for precise control over temperature and airflow. This adaptability not only enhances comfort but also contributes to significant energy savings. The inclusion of high-efficiency cooling coils further optimizes performance, making it an excellent choice for businesses looking to lower their operational costs.

The RT-PRC010-EN model integrates smart controls that allow for seamless integration into building management systems. These controls facilitate real-time monitoring and diagnostics, enabling facility managers to maintain optimum operational efficiency and promptly address any maintenance needs. This technology minimizes downtime and extends the lifecycle of the unit.

Moreover, the unit’s construction is targeted toward resilience and durability. Built with a corrosion-resistant cabinet and extensive insulation, the RT-PRC010-EN can withstand the rigors of various climates, making it suitable for installation across different geographical locations. Its compact design allows for easy installation on rooftops, maximizing space utilization in commercial buildings.

Another standout characteristic is the unit's versatility in application. The RT-PRC010-EN can be tailored to suit a wide range of commercial settings, including retail establishments, educational institutions, and healthcare facilities. Options for various indoor and outdoor configurations enhance its adaptability to specific operational requirements.

In conclusion, the Trane RT-PRC010-EN stands out as an energy-efficient, reliable, and versatile solution for commercial heating and cooling needs. Its advanced features, smart controls, and robust design make it an ideal choice for businesses looking to enhance comfort while minimizing energy expenditures and ensuring operational reliability. Whether dealing with extreme weather conditions or managing indoor air quality concerns, this rooftop unit provides a comprehensive solution tailored to modern commercial requirements.