Trane RT-PRC010-EN manual Options

Page 96

Options

Options

A full range of factory-installed modular options are available on standard ship cycles, allowing your rooftop design to best suit each individual application.

Cooling Only/Heating Casings

Cooling Only —Two casing choices are available, one designed for high airside efficiency and one for sound sensitive applications.The 90 to 130 tons are extended casing only.

Electric Heat — Nickel-chromium electric heating elements in individually fused circuits of 48 amps or less and with all necessary safeties. A full range of sizing options is available.

Natural Gas Heat --Two Stage and Limited Modulation —Two-pass stainless steel tubular free floating heat exchanger has industrial type burner and combustion blower. Available with high or low fire and UL or CSA approval.

Natural Gas Heat - Full Modulation — The heat exchanger drum, tubes and front and rear headers are constructed of the most corrosion resistant austenitic stainless steel alloys available.

Steam Heat — ARI certified type NS coil with non-freeze steam distribution. Coils are pitched for drainage and are provided with steam modulating valve with actuator. High and low heat options are available.

Hot Water Heat — ARI certified typeW coil mounted for drainage and provided with hot water modulating valve with actuator. High and low heat options are available.

Power Supplies

Rooftops are available with 200, 230, 460 and 575 voltage power supplies.

Exhaust

No Exhaust — Rooftops can be built for makeup air applications with no exhaust. Relief opening is sealed watertight.

Barometric Relief — Gravity dampers are provided that open to relieve positive pressure.

50 Percent Exhaust Fan — One double inlet forward-curved fan can exhaust up to 50 percent of supply air. Control is on/off based on economizer damper

position. Barometric dampers at fan outlet prevent air backdraft.

100 Percent Modulating Exhaust Fan — Two double inlet forward-curved fans can exhaust up to 100 percent supply air. Fans operate when economizer damper is open greater than minimum position. Discharge dampers at fan outlet modulate in response to economizer damper position on

CV rooftops.

100 Percent Modulating Exhaust with Statitrac™ Control — For both CV and VAV rooftops, the 100 percent modulating exhaust discharge dampers are modulated in response to building pressure. A differential pressure control system, called Statitrac™, uses a differential pressure transducer to compare indoor building pressure to atmospheric pressure.The FC exhaust fan is turned on when required to lower building static pressure to setpoint.The Statitrac control system then modulates the discharge dampers to control the building pressure to within the adjustable, specified dead band that is set at the Human Interface Panel.

Filters

No Filters (two inch throwaway filter rack only) — complete set of two-inch thick filter racks, without the filter media to accommodate applications which require field supplied filters.

No Filters (bag/cartridge with prefilter filter rack) — long-lasting galvanized steel frame without the filter media to accommodate applications which require field supplied filters.

Throwaway —Two-inch, 30 percent efficient throwaway filters, includes rack as standard.

Cleanable Wire Mesh —Two-inch permanent washable wire mesh filters are provided with metal frame.

High-EfficiencyThrowaway —Two inch throwaway filters include rack and have an average arrestance in excess of 90 percent when tested in accordance with ASHRAE 52-76.

90-95 Percent Bag Filter (with prefilter)

— Glass fiber extended media bag filter is mounted in a galvanized steel frame. 90-95 percent dust spot efficiency.Two-inch throwaway prefilters are included with this option.

90-95 Percent Cartridge Filter (with prefilter) —These twelve-inch deep cartridge filters are mounted in a galvanized steel frame.They are Class 1 listed by Underwriters Laboratories and have a 90-95 percent dust spot efficiency per ASHRAE 52-76.To ensure maximum cartridge filter life, two-inch prefilters are included.

Fresh Air

0To 25 Percent Manual Outside Air — Includes outside air opening with moisture eliminator and manually positioned damper for drawing up to 25 percent outside air. (20-75 tons only)

Economizer — Includes the primary temperature controls necessary to automatically use outdoor air for free cooling. Option includes modulating return and outside air dampers, high ambient temperature lockout, minimum position control and spring return motor. Standard low leak outside air dampers are provided with a leakage rate of 2.5 percent of nominal airflow at one inchW.C. static pressure. The 0 to 100% fresh air economizer has three optional economizer controls available: comparative enthalpy, reference enthalpy, or dry bulb control.

System Control

Constant Volume — Provided with all the necessary controls to operate rooftop from a zone sensor, including CV microprocessor unit control module, a microprocessor compressor controller and a unit mounted Human Interface Panel.

VAV Supply AirTemperature control without inlet guide vanes — Provided with all the necessary controls to operate a VAV rooftop from the discharge air temperature, including discharge air microprocessor controller and discharge air sensor.The microprocessor controller coordinates the economizer control and the stages of cooling with zone or outdoor air reset capabilities and an adjustable control band to fine-tune the control to specific applications.

96

RT-PRC010-EN

Image 96
Contents 20 75Tons 90 130Tons Introduction American Standard IncContents Features and Benefits Standard FeaturesOptional Features Field Installed AccessoriesFeatures Summary Installation EaseEasy to Service ReliabilityIntegrated Comfort System ICS SimplifyingThe Comfort SystemTracer control points for IntelliPak Rooftops Features and Benefits Optimum Building Comfort Control FansWith Inlet GuideVanesVariable Frequency Drives VFD Proven DesignThroughTesting and Research Trane 3-DScroll CompressorSimple Design with 70% Fewer Parts LowTorqueVariationApplication Considerations Percent Exhaust System Barometric Relief DampersPanel C Dimensions Horizontal Discharge20 75 tons SXHF, SFHF, SLHF, SSHF, SXHF, SFHF, SLHF, Sshf UnitsTable AC-4 SXHG, SLHG, Sshg Panel a and B Dimensions Table AC-5 SXHG, SLHG, Sshg Z Dimensions2508 17.4 High Capacity Evaporator Coil Corrosive AtmospheresVentilation Override Sequences Natural Gas Heating ConsiderationsAcoustical Considerations Clearance RequirementsFigure AC-4 Unit Placement Duct DesignSelection Procedure DetermineTotalWinter Heating Load Electric Heating SystemGas Heating System Natural Gas HotWater HeatingSupply Fan Motor Sizing Exhaust Fan Motor SizingAltitude Corrections Selection Procedure Model Number Description H F C1 1 567 General Data Table GD-1- General Data 20-40Tons20Ton 25Ton 30Ton 40Ton RPMFilters Table GD-2 General Data 50-75Tons 50Ton 55Ton 60Ton 70Ton 75Ton Low Ambient Option Min. Outside AirTempTable GD-3 General Data 90-130Tons 90Ton 105Ton 115Ton 130Ton50% 100% Number/Size/Type 22/FC Table GD-4 ARI Performance Data Table GD-5 ARI Correction MultipliersEER Iplv Performance Adjustment Factors Table PAF-1 Enthalpy of Saturated AIRPerformance 20Ton Data Performance 25Ton Data Performance 30Ton Data Performance 40Ton Data 345 452 265 496 183561 207 451 399 493 302 537 199 429 389 468 292 431 551Performance 50Ton Data Performance 55Ton Data Performance 60Ton Data AmbientTemperature F Performance 70Ton DataFlow Performance 75Ton Data Performance 90Ton Data Performance 105Ton Data Performance 115, 130TonsPerformance Data Table PD-24 Natural Gas Heating CapacitiesTable PD-25- Natural Gas Heating Capacities Table PD-26 Steam Heating Capacities Q/ITD1Table PD-28 20 to 75-Tons Electric Heat AirTemperature Rise Table PD-29- 90To 130-Ton Electric Heat AirTemperature RiseTable PD-30- Electric Heat KW Ranges Table PD-31- HotWater Heating Capacities Q/ITD1 20, 25Tons RPM BHPPressure 4000 1037 1225 12711364 140910 HP 1200 RPM 80% 1100 RPM 6000 883 927 968 1007 1043 1078 22.221400 RPM Wocfm 40% 1300 RPM 25 HP Inches 1200 RPM 50% 20 HP Table PD-35 Supply Fan PerformanceWITH Inletvanes 30Ton 6000 890 933 974 1012 10491357 20.45 Dual 18 X 18 Fans Wocfm Entrance Losses Ithout Exhaust15 HP 1200 RPM Fan Curve Limits 1000 RPM 10 HP40, 50, 55Tons 30.4732.36 40, 50, 55Tons 800 14.86 820 1161 32.63 Cfm Total Static Pressure Std 250 500 750 000Inches w.c 60, 70, 75Tons 43.8560, 70, 75Tons 14000 729 800 RPM 20 HP 70% 15 HP 27000 646 690 732 773 808 840 10.71 872 904 13.34 28000 667 710 750 791 826 10.15 85730000 708 749 787 826 10.13 861 897 12.88 928 14.40 957 15.80 98527000 1363 39.85 1388 41.68 1414 43.54 1437 45.26 1461 29000 1375 42.04 1398 43.93 1423 45.91 14451469 49.80 1491 1515 53.66 30000 1382 43.16 1406 45.18 142827000 695 734 770 805 840 904 13.44 935 14.77 28000 718 756 791 825 10.28 858891 12.90 922 14.26 952 15.65 29000 741 778 812 845 897 13.19 928 14.59 958 16.05 9871579 32000 1442 49.55 14641496 55.23 1518 57.33 1541 59.53 1565 37000 1494Performance 105,115,130Tons 1623 76.74 1640 78.95 00 R 15001100 100 900 RP25.35 26.9532.56 1233 34.40 1255 36.26 1277 38.17 46000 1138 26.67 30.40 1216 32.05 1240 33.79 1086 23.371625 76.92 1643 79.30 46000 1624 1641 79.40Performance 20 -75Tons Data Table PD-44 Component Static Pressure Drops in.W.GSFHF/G SEHF/G SLHF/G SSHF/G Performance 90-130Tons Data Table PD-45 Component Static Pressure Drops in.W.GSFHF/G SLHF/G SSHF/GTable PD-46 20-75 -Tons Supply Air Fan Drive Selections Table PD-47 90-130 -Tons Supply Air Fan Drive SelectionsBHP RPM 835 39.71 859885 44.08 910 46.33 934 48.32 Table PD-50 20-75Tons 100% Exhaust Fan Drive Selections Table PD-51 90-130Tons -100% Exhaust Fan Drive SelectionsTable PD-52 20-75Tons 50% Exhaust Fan Performance Table PD-53 90-130 Tons 50% Exhaust Fan Performance18.97 835 19.86 859 20.87 885 22.05 910 23.18 934 24.17 Table PD-54- 50% Exhaust Fan Drive Selections Controls VAV UnitsVAV Units Only Supply Air Setpoint Reset Reset based on outdoor air temperatureReset based on zone temperature ZoneTemperature Control Unoccupied Zone Heating and CoolingCV Units CV Units OnlyHeating Gas Heating -Two-Stage Unoccupied ZoneTemperature Control Cooling and Heating Gas Heating Modulating GasElectric Heating HotWater or Steam HeatingVAV/CV Units Exhaust sequence C Purge sequence DPurge with duct pressure control E Human Interface Panel H.IHuman Interface Panel Main Menu Generic Building Automation System odule GbasEvaporator Coil Frost Protection Occupied/Unoccupied Switching Dry BulbTemperature Control of EconomizerNight Setback Sensors Occupied/Unoccupied input on the RTMElectrical Service Sizing Dual Source Power units 200VElectrical Data Set 2. Rooftop units with Electric HeatRLA1 LRA 178 21.8 143Table ED-6 -Voltage Utilization Range 48.5 39.0 Motor Hp48.5 39.0 FLADimensional 20 75Tons Figure DD-1 20-75Ton Cooling Only Unit Dimensions Sahf Detail B Covers 40, 60, 70 and 75 TON Units20 & 25 5-8 15/ 16 24-1 3 5/ 8 1-7 9 Sahf 10’-1 7 ’-10 15/ 16 2’-0 ’-6Dimensional 90 130Tons Figure DD-5 90 130Tons Service ClearanceFigure DD-6 90 130Ton Roof Curb Dimensions Section B-B RT-PRC010-ENDimensional Field Installed SensorsConstant CV and VAV Integrated Comfort System SensorsWeights TableW-1 -Approximate OperatingWeights Lbs./KgSL/SS 14740 15380 15930 16080Options OptionsAmbient Control Agency ApprovalMiscellaneous Options Electronic Zone Sensors Roof CurbMechanical Specifications GeneralSupply Fan 20 75Ton Units 90 130Ton UnitsControls Unit ControllerPermanent cleanable wire mesh option High efficiency throwaway optionPercent bag filter option Percent cartridge filter optionOutside Air General Manual outside air optionPercent modulating economizer option Ultra low-leak economizer dampers optionAccessories Heating SystemLiterature Order Number File Number PL-RT-S*HF/S*HG-20-130TONS-PRC0010-EN-10-2001Supersedes RT-DS-8 05/98 Stocking Location Inland-LaCrosse

RT-PRC010-EN specifications

The Trane RT-PRC010-EN is a prominent model in the line of Trane's packaged rooftop units, designed to offer efficient heating, cooling, and ventilation for commercial applications. Renowned for its robust performance, this unit integrates advanced technologies and superior engineering to meet diverse environmental needs while ensuring energy efficiency and reliability.

One of the key features of the RT-PRC010-EN is its energy-efficient operation. The unit is equipped with variable-speed fans and scroll compressors, which allow for precise control over temperature and airflow. This adaptability not only enhances comfort but also contributes to significant energy savings. The inclusion of high-efficiency cooling coils further optimizes performance, making it an excellent choice for businesses looking to lower their operational costs.

The RT-PRC010-EN model integrates smart controls that allow for seamless integration into building management systems. These controls facilitate real-time monitoring and diagnostics, enabling facility managers to maintain optimum operational efficiency and promptly address any maintenance needs. This technology minimizes downtime and extends the lifecycle of the unit.

Moreover, the unit’s construction is targeted toward resilience and durability. Built with a corrosion-resistant cabinet and extensive insulation, the RT-PRC010-EN can withstand the rigors of various climates, making it suitable for installation across different geographical locations. Its compact design allows for easy installation on rooftops, maximizing space utilization in commercial buildings.

Another standout characteristic is the unit's versatility in application. The RT-PRC010-EN can be tailored to suit a wide range of commercial settings, including retail establishments, educational institutions, and healthcare facilities. Options for various indoor and outdoor configurations enhance its adaptability to specific operational requirements.

In conclusion, the Trane RT-PRC010-EN stands out as an energy-efficient, reliable, and versatile solution for commercial heating and cooling needs. Its advanced features, smart controls, and robust design make it an ideal choice for businesses looking to enhance comfort while minimizing energy expenditures and ensuring operational reliability. Whether dealing with extreme weather conditions or managing indoor air quality concerns, this rooftop unit provides a comprehensive solution tailored to modern commercial requirements.