Trane RT-PRC010-EN manual 800 14.86 820, 1161 32.63 Cfm Total Static Pressure Std 250 500 750 000

Page 54

Performance

(40, 50, 55Tons)

Data

 

 

 

 

 

 

 

Table PD-37 — Supply Fan PerformanceWITH INLETVANES — 40, 50 and 55Ton

Cfm

 

 

 

 

 

 

 

Total Static Pressure

 

 

 

 

 

 

 

Std

 

.250

 

.500

 

.750

 

1.000

1.250

1.500

1.750

2.000

Air

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

8000

318

.79

406

1.35

485

1.98

555

2.70

618

3.49

675

4.31

726

5.17

773

6.06

9000

339

1.01

416

1.56

491

2.24

558

2.97

621

3.79

678

4.67

730

5.58

778

6.52

10000

364

1.28

428

1.81

499

2.53

564

3.30

624

4.13

680

5.04

733

6.00

781

7.00

11000

391

1.63

444

2.13

509

2.85

571

3.68

629

4.53

684

5.45

735

6.44

784

7.48

12000

419

2.04

463

2.51

521

3.22

580

4.08

636

4.99

689

5.92

739

6.93

787

8.00

13000

448

2.53

486

2.97

536

3.66

591

4.52

645

5.49

696

6.47

744

7.49

791

8.57

14000

478

3.09

511

3.53

553

4.19

604

5.03

655

6.02

704

7.07

751

8.12

796

9.22

15000

507

3.74

537

4.18

574

4.80

619

5.63

667

6.60

714

7.69

760

8.82

803

9.95

16000

537

4.46

565

4.93

597

5.52

636

6.32

680

7.28

725

8.36

769

9.54

812

10.74

17000

567

5.28

593

5.78

622

6.35

656

7.11

695

8.05

738

9.12

780

10.30

821

11.56

18000

597

6.20

622

6.74

648

7.30

678

8.02

713

8.93

752

9.99

792

11.16

832

12.43

19000

627

7.22

652

7.80

675

8.37

702

9.05

733

9.92

768

10.97

806

12.12

844

13.38

20000

657

8.35

681

8.98

703

9.55

727

10.22

755

11.05

786

12.06

821

13.21

857

14.45

21000

687

9.60

711

10.27

732

10.87

754

11.53

779

12.32

807

13.28

838

14.41

871

15.64

22000

718

10.96

741

11.67

761

12.31

781

12.97

804

13.74

829

14.66

857

15.74

888

16.97

22500

733

11.69

756

12.42

776

13.08

795

13.74

817

14.50

841

15.40

868

16.46

897

17.68

23000

748

12.45

770

13.20

790

13.88

810

14.55

830

15.31

853

16.19

878

17.23

906

18.42

24000

779

14.08

800

14.86

820

15.59

838

16.28

857

17.03

878

17.88

901

18.87

926

20.02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cfm

 

 

 

 

 

 

 

Total Static Pressure

 

 

 

 

 

 

 

Std

2.250

 

2.500

 

2.750

 

3.000

3.250

3.500

3.750

4.000

Air

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

8000

817

6.98

858

7.92

896

8.89

932

9.88

966

10.88

998

11.89

1029

12.90

1058

13.93

9000

823

7.50

865

8.50

904

9.52

942

10.58

977

11.65

1010

12.74

1042

13.85

1073

14.97

10000

827

8.02

870

9.08

910

10.16

948

11.26

985

12.39

1019

13.55

1052

14.73

1084

15.92

11000

830

8.56

873

9.67

914

10.81

953

11.96

990

13.15

1026

14.35

1059

15.58

1092

16.83

12000

833

9.11

876

10.27

917

11.46

956

12.67

994

13.91

1030

15.17

1064

16.46

1098

17.76

13000

836

9.71

879

10.90

920

12.13

959

13.39

997

14.69

1033

16.00

1068

17.34

1102

18.70

14000

840

10.37

882

11.58

923

12.84

962

14.14

999

15.47

1036

16.84

1071

18.23

1105

19.65

15000

846

11.11

887

12.33

926

13.61

965

14.93

1002

16.30

1038

17.71

1073

19.14

1107

20.61

16000

853

11.95

893

13.18

931

14.47

969

15.81

1006

17.19

1042

18.62

1076

20.09

1110

21.60

17000

861

12.84

900

14.13

938

15.43

975

16.77

1010

18.17

1046

19.62

1080

21.11

1113

22.64

18000

871

13.77

909

15.12

945

16.48

981

17.85

1016

19.26

1051

20.71

1084

22.22

1117

23.76

19000

881

14.74

918

16.15

954

17.58

989

19.01

1023

20.46

1057

21.92

1090

23.43

1122

24.99

20000

893

15.80

929

17.23

964

18.72

998

20.22

1031

21.73

1064

23.24

1096

24.77

1128

26.34

21000

906

16.98

940

18.40

974

19.91

1008

21.46

1040

23.05

1072

24.63

1104

26.21

1135

27.81

22000

920

18.28

953

19.69

986

21.19

1018

22.77

1050

24.40

1082

26.05

1112

27.71

1143

29.37

22500

928

18.99

960

20.39

992

21.88

1024

23.46

1055

25.10

1086

26.78

1117

28.47

1147

30.17

23000

936

19.73

967

21.13

998

22.61

1030

24.18

1061

25.82

1092

27.52

1122

29.24

1151

30.98

24000

954

21.31

983

22.70

1012

24.17

1043

25.73

1073

27.36

1102

29.07

1132

30.83

1161

32.63

Cfm

 

 

Total Static Pressure

 

 

 

 

Notes:

Std

4.250

 

4.500

 

4.750

 

 

5.000

1.

Fan performance for 40, 50, and 55 ton rooftops is

 

 

 

 

 

 

identical. However, note maximum motor hp size for

Air

RPM

BHP

RPM

BHP

RPM

BHP

RPM

 

BHP

 

 

 

each size. Contact your local Trane representative for

8000

1087

14.97

1114

16.01

1141

17.07

1166

 

18.13

 

information on non-standard motors.

9000

1102

16.10

1131

17.24

1158

18.39

 

 

2.

Shaded areas at table extremes note non-standard

10000

1114

17.13

1143

18.36

 

 

 

 

 

 

Bhp or Rpm selection. Contact your local Trane

11000

1123

18.11

1153

19.40

 

 

 

 

 

 

representative for more information.

 

 

 

 

3.

Supply fan performance table includes internal

12000

1129

19.08

1160

20.43

 

 

 

 

 

 

 

 

 

 

resistance of rooftop. For total static pressure

13000

1134

20.08

1165

21.48

 

 

 

 

 

 

 

 

 

 

 

 

determination, system external static must be added

14000

1137

21.08

1169

22.54

 

 

 

 

 

 

to appropriate component static pressure drops

15000

1140

22.09

 

 

 

 

 

 

 

 

(evaporator coil, filters, optional economizer,

16000

1143

23.13

 

 

 

 

 

 

 

 

optional exhaust fan, optional heating system,

17000

1146

24.21

 

 

 

 

 

 

 

 

optional cooling only extended casing, optional roof

18000

1149

25.35

 

 

 

 

 

 

 

 

curb).

 

 

 

 

 

 

4.

Maximum Cfm (for UL approval) as follows: 40 Ton

19000

1153

26.59

 

 

 

 

 

 

 

 

 

 

 

 

 

 

— 18,000 Cfm, 50 Ton — 22,500 Cfm, 55 Ton —

20000

1159

27.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24,000 Cfm

21000

1165

29.43

 

 

 

 

 

 

5.

Minimum motor horsepower is 7.5 hp.

22000

 

 

 

 

 

 

 

 

6.

Maximum motor horsepower as follows: 40 Ton —

22500

 

 

 

 

 

 

 

 

 

 

30 hp, 50 Ton — 30 hp, 55 Ton — 30 hp

23000

 

 

 

 

 

 

 

 

7.

Maximum 7.5 hp through 15 hp motor Rpm is 1,141

24000

 

 

 

 

 

 

 

 

 

 

Rpm, maximum 20 hp through 30 hp motor Rpm is

 

 

 

 

 

 

 

 

 

 

 

1,170 Rpm.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8.

See RT-EB-104 for further details.

54

RT-PRC010-EN

Image 54
Contents 20 75Tons 90 130Tons Introduction American Standard IncContents Optional Features Features and BenefitsStandard Features Field Installed AccessoriesEasy to Service Features SummaryInstallation Ease ReliabilityIntegrated Comfort System ICS SimplifyingThe Comfort SystemTracer control points for IntelliPak Rooftops Features and Benefits Optimum Building Comfort Control FansWith Inlet GuideVanesVariable Frequency Drives VFD Simple Design with 70% Fewer Parts Proven DesignThroughTesting and ResearchTrane 3-DScroll Compressor LowTorqueVariationApplication Considerations Percent Exhaust System Barometric Relief Dampers20 75 tons SXHF, SFHF, SLHF, SSHF, Panel C DimensionsHorizontal Discharge SXHF, SFHF, SLHF, Sshf UnitsTable AC-4 SXHG, SLHG, Sshg Panel a and B Dimensions Table AC-5 SXHG, SLHG, Sshg Z Dimensions2508 17.4 Ventilation Override Sequences High Capacity Evaporator CoilCorrosive Atmospheres Natural Gas Heating ConsiderationsAcoustical Considerations Clearance RequirementsFigure AC-4 Unit Placement Duct DesignSelection Procedure Gas Heating System Natural Gas DetermineTotalWinter Heating LoadElectric Heating System HotWater HeatingSupply Fan Motor Sizing Exhaust Fan Motor SizingAltitude Corrections Selection Procedure Model Number Description H F C1 1 567 20Ton 25Ton 30Ton 40Ton General DataTable GD-1- General Data 20-40Tons RPMFilters Table GD-2 General Data 50-75Tons 50Ton 55Ton 60Ton 70Ton 75Ton Low Ambient Option Min. Outside AirTempTable GD-3 General Data 90-130Tons 90Ton 105Ton 115Ton 130Ton50% 100% Number/Size/Type 22/FC Table GD-4 ARI Performance Data Table GD-5 ARI Correction MultipliersEER Iplv Performance Adjustment Factors Table PAF-1 Enthalpy of Saturated AIRPerformance 20Ton Data Performance 25Ton Data Performance 30Ton Data 561 207 451 399 493 302 537 199 429 389 468 292 Performance 40Ton Data345 452 265 496 183 431 551Performance 50Ton Data Performance 55Ton Data Performance 60Ton Data AmbientTemperature F Performance 70Ton DataFlow Performance 75Ton Data Performance 90Ton Data Performance 105Ton Data Performance 115, 130TonsTable PD-25- Natural Gas Heating Capacities Performance DataTable PD-24 Natural Gas Heating Capacities Table PD-26 Steam Heating Capacities Q/ITD1Table PD-28 20 to 75-Tons Electric Heat AirTemperature Rise Table PD-29- 90To 130-Ton Electric Heat AirTemperature RiseTable PD-30- Electric Heat KW Ranges Table PD-31- HotWater Heating Capacities Q/ITD1 20, 25Tons RPM BHPPressure 1364 4000 10371225 1271 140910 HP 1200 RPM 80% 1100 RPM 6000 883 927 968 1007 1043 1078 22.221400 RPM Wocfm 40% 1300 RPM 25 HP Inches 1200 RPM 50% 20 HP Table PD-35 Supply Fan PerformanceWITH Inletvanes 30Ton 6000 890 933 974 1012 10491357 20.45 15 HP 1200 RPM Fan Curve Limits Dual 18 X 18 Fans Wocfm Entrance LossesIthout Exhaust 1000 RPM 10 HP40, 50, 55Tons 30.4732.36 40, 50, 55Tons 800 14.86 820 1161 32.63 Cfm Total Static Pressure Std 250 500 750 000Inches w.c 60, 70, 75Tons 43.8560, 70, 75Tons 14000 729 800 RPM 20 HP 70% 15 HP 30000 708 749 787 826 10.13 861 27000 646 690 732 773 808 840 10.71 872904 13.34 28000 667 710 750 791 826 10.15 857 897 12.88 928 14.40 957 15.80 9851469 49.80 1491 27000 1363 39.85 1388 41.68 1414 43.54 1437 45.26 146129000 1375 42.04 1398 43.93 1423 45.91 1445 1515 53.66 30000 1382 43.16 1406 45.18 1428891 12.90 922 14.26 952 15.65 29000 741 778 812 845 27000 695 734 770 805 840904 13.44 935 14.77 28000 718 756 791 825 10.28 858 897 13.19 928 14.59 958 16.05 9871496 55.23 1518 57.33 1541 59.53 1565 157932000 1442 49.55 1464 37000 1494Performance 105,115,130Tons 1100 1623 76.74 1640 78.9500 R 1500 100 900 RP32.56 1233 34.40 1255 36.26 1277 38.17 46000 1138 26.67 25.3526.95 30.40 1216 32.05 1240 33.79 1086 23.371625 76.92 1643 79.30 46000 1624 1641 79.40Performance 20 -75Tons Data Table PD-44 Component Static Pressure Drops in.W.GSFHF/G SEHF/G SLHF/G SSHF/G SFHF/G Performance 90-130Tons DataTable PD-45 Component Static Pressure Drops in.W.G SLHF/G SSHF/GTable PD-46 20-75 -Tons Supply Air Fan Drive Selections Table PD-47 90-130 -Tons Supply Air Fan Drive SelectionsBHP RPM 835 39.71 859885 44.08 910 46.33 934 48.32 Table PD-50 20-75Tons 100% Exhaust Fan Drive Selections Table PD-51 90-130Tons -100% Exhaust Fan Drive SelectionsTable PD-52 20-75Tons 50% Exhaust Fan Performance Table PD-53 90-130 Tons 50% Exhaust Fan Performance18.97 835 19.86 859 20.87 885 22.05 910 23.18 934 24.17 Table PD-54- 50% Exhaust Fan Drive Selections Controls VAV UnitsVAV Units Only Reset based on zone temperature Supply Air Setpoint ResetReset based on outdoor air temperature ZoneTemperature Control Unoccupied Zone Heating and CoolingCV Units CV Units OnlyHeating Gas Heating -Two-Stage Electric Heating Unoccupied ZoneTemperature Control Cooling and HeatingGas Heating Modulating Gas HotWater or Steam HeatingVAV/CV Units Purge with duct pressure control E Exhaust sequence CPurge sequence D Human Interface Panel H.IHuman Interface Panel Main Menu Generic Building Automation System odule GbasEvaporator Coil Frost Protection Night Setback Sensors Occupied/Unoccupied SwitchingDry BulbTemperature Control of Economizer Occupied/Unoccupied input on the RTMElectrical Data Electrical Service SizingDual Source Power units 200V Set 2. Rooftop units with Electric HeatRLA1 LRA 178 21.8 14348.5 39.0 Table ED-6 -Voltage Utilization Range48.5 39.0 Motor Hp FLADimensional 20 75Tons Figure DD-1 20-75Ton Cooling Only Unit Dimensions Sahf Detail B Covers 40, 60, 70 and 75 TON Units20 & 25 5-8 15/ 16 24-1 3 5/ 8 1-7 9 Sahf 10’-1 7 ’-10 15/ 16 2’-0 ’-6Dimensional 90 130Tons Figure DD-5 90 130Tons Service ClearanceFigure DD-6 90 130Ton Roof Curb Dimensions Section B-B RT-PRC010-ENDimensional Field Installed SensorsConstant CV and VAV Integrated Comfort System SensorsSL/SS WeightsTableW-1 -Approximate OperatingWeights Lbs./Kg 14740 15380 15930 16080Options OptionsAmbient Control Agency ApprovalMiscellaneous Options Electronic Zone Sensors Roof CurbMechanical Specifications GeneralControls Supply Fan 20 75Ton Units90 130Ton Units Unit ControllerPercent bag filter option Permanent cleanable wire mesh optionHigh efficiency throwaway option Percent cartridge filter optionPercent modulating economizer option Outside Air GeneralManual outside air option Ultra low-leak economizer dampers optionAccessories Heating SystemLiterature Order Number File Number PL-RT-S*HF/S*HG-20-130TONS-PRC0010-EN-10-2001Supersedes RT-DS-8 05/98 Stocking Location Inland-LaCrosse

RT-PRC010-EN specifications

The Trane RT-PRC010-EN is a prominent model in the line of Trane's packaged rooftop units, designed to offer efficient heating, cooling, and ventilation for commercial applications. Renowned for its robust performance, this unit integrates advanced technologies and superior engineering to meet diverse environmental needs while ensuring energy efficiency and reliability.

One of the key features of the RT-PRC010-EN is its energy-efficient operation. The unit is equipped with variable-speed fans and scroll compressors, which allow for precise control over temperature and airflow. This adaptability not only enhances comfort but also contributes to significant energy savings. The inclusion of high-efficiency cooling coils further optimizes performance, making it an excellent choice for businesses looking to lower their operational costs.

The RT-PRC010-EN model integrates smart controls that allow for seamless integration into building management systems. These controls facilitate real-time monitoring and diagnostics, enabling facility managers to maintain optimum operational efficiency and promptly address any maintenance needs. This technology minimizes downtime and extends the lifecycle of the unit.

Moreover, the unit’s construction is targeted toward resilience and durability. Built with a corrosion-resistant cabinet and extensive insulation, the RT-PRC010-EN can withstand the rigors of various climates, making it suitable for installation across different geographical locations. Its compact design allows for easy installation on rooftops, maximizing space utilization in commercial buildings.

Another standout characteristic is the unit's versatility in application. The RT-PRC010-EN can be tailored to suit a wide range of commercial settings, including retail establishments, educational institutions, and healthcare facilities. Options for various indoor and outdoor configurations enhance its adaptability to specific operational requirements.

In conclusion, the Trane RT-PRC010-EN stands out as an energy-efficient, reliable, and versatile solution for commercial heating and cooling needs. Its advanced features, smart controls, and robust design make it an ideal choice for businesses looking to enhance comfort while minimizing energy expenditures and ensuring operational reliability. Whether dealing with extreme weather conditions or managing indoor air quality concerns, this rooftop unit provides a comprehensive solution tailored to modern commercial requirements.