Trane RT-PRC010-EN manual 40, 50, 55Tons, 30.47, 32.36

Page 52

 

Performance

(40, 50, 55Tons)

 

 

Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table PD-36 — Supply Fan PerformanceWithVARIABLE FREQUENCY DRIVE orWITHOUT INLETVANES — 40, 50 and 55Tons

Cfm

 

 

 

 

 

 

 

Total Static Pressure

 

 

 

 

 

 

 

Std

 

.250

 

.500

 

.750

 

1.000

1.250

1.500

1.750

2.000

Air

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

8000

290

.66

396

1.27

479

1.95

550

2.67

613

3.44

671

4.23

723

5.05

770

5.90

9000

298

.77

400

1.44

482

2.16

553

2.93

616

3.75

673

4.61

725

5.49

774

6.39

10000

311

.94

404

1.61

486

2.38

556

3.20

618

4.07

675

4.99

727

5.93

776

6.89

11000

329

1.16

409

1.79

490

2.63

559

3.50

621

4.41

677

5.37

729

6.37

778

7.40

12000

349

1.43

414

2.00

494

2.89

563

3.81

624

4.77

680

5.78

731

6.82

780

7.90

13000

370

1.75

424

2.26

499

3.16

567

4.15

628

5.16

683

6.21

734

7.30

782

8.43

14000

391

2.12

438

2.60

504

3.44

571

4.49

632

5.57

687

6.67

737

7.80

785

8.97

15000

413

2.54

455

3.01

510

3.77

576

4.86

636

5.99

690

7.15

741

8.33

789

9.55

16000

435

3.02

474

3.50

520

4.18

581

5.24

640

6.43

695

7.65

745

8.89

792

10.16

17000

457

3.54

494

4.06

534

4.68

586

5.65

645

6.89

699

8.17

749

9.47

796

10.79

18000

479

4.13

515

4.68

550

5.29

595

6.15

650

7.37

703

8.71

753

10.07

800

11.46

19000

501

4.78

536

5.38

569

5.98

607

6.76

656

7.89

708

9.27

758

10.70

804

12.14

20000

524

5.49

558

6.15

588

6.75

622

7.49

664

8.50

713

9.85

762

11.34

809

12.84

21000

546

6.28

580

7.00

608

7.61

639

8.32

676

9.25

719

10.49

767

12.00

813

13.57

22000

569

7.14

602

7.92

629

8.55

658

9.26

690

10.12

728

11.25

773

12.70

818

14.32

22500

580

7.60

613

8.40

640

9.05

667

9.76

698

10.60

734

11.68

776

13.07

820

14.70

23000

591

8.08

624

8.90

651

9.58

677

10.29

706

11.11

740

12.15

780

13.48

823

15.09

24000

614

9.10

646

9.97

672

10.70

697

11.41

724

12.22

754

13.19

789

14.41

829

15.93

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cfm

 

 

 

 

 

 

 

Total Static Pressure

 

 

 

 

 

 

 

Std

2.250

 

2.500

 

2.750

 

3.000

3.250

3.500

3.750

4.000

Air

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

8000

814

6.80

854

7.73

892

8.69

927

9.67

961

10.66

993

11.67

1023

12.69

1053

13.71

9000

819

7.32

861

8.28

901

9.27

938

10.31

972

11.37

1006

12.45

1037

13.55

1068

14.67

10000

822

7.88

865

8.89

906

9.92

944

10.98

980

12.07

1015

13.20

1048

14.35

1079

15.53

11000

824

8.45

867

9.52

908

10.61

948

11.72

985

12.85

1021

14.00

1055

15.18

1087

16.40

12000

826

9.01

869

10.15

910

11.30

950

12.47

988

13.66

1024

14.87

1059

16.09

1092

17.34

13000

828

9.59

871

10.78

912

11.99

952

13.23

989

14.48

1026

15.75

1061

17.04

1095

18.34

14000

830

10.18

873

11.42

914

12.69

954

13.98

991

15.30

1028

16.63

1063

17.98

1097

19.35

15000

833

10.80

876

12.09

917

13.40

956

14.75

994

16.12

1030

17.51

1065

18.92

1099

20.35

16000

837

11.46

879

12.78

920

14.14

958

15.54

996

16.96

1032

18.40

1067

19.87

1101

21.36

17000

840

12.14

882

13.52

923

14.92

961

16.36

999

17.82

1035

19.32

1069

20.83

1103

22.38

18000

844

12.86

886

14.28

926

15.73

964

17.21

1002

18.72

1037

20.26

1072

21.82

1106

23.41

19000

848

13.60

890

15.08

930

16.58

968

18.11

1005

19.66

1040

21.24

1075

22.85

1108

24.48

20000

852

14.36

894

15.90

934

17.46

972

19.04

1008

20.64

1044

22.27

1078

23.92

1111

25.60

21000

857

15.15

898

16.75

938

18.37

976

20.00

1012

21.66

1047

23.33

1081

25.03

1114

26.75

22000

861

15.96

902

17.63

942

19.30

980

20.99

1016

22.70

1051

24.43

1085

26.18

1118

27.95

22500

864

16.38

905

18.07

944

19.78

982

21.50

1018

23.24

1053

25.00

1087

26.77

1120

28.57

23000

866

16.80

907

18.52

946

20.26

984

22.01

1020

23.78

1055

25.57

1089

27.37

1122

29.19

24000

871

17.66

912

19.45

951

21.25

988

23.06

1024

24.89

1059

26.73

1093

28.59

1125

30.47

Cfm

 

 

Total Static Pressure

 

 

 

Std

4.250

 

4.500

 

4.750

 

 

5.000

Air

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

8000

1081

14.75

1108

15.78

1134

16.83

1160

17.88

9000

1097

15.80

1125

16.94

1152

18.08

 

 

10000

1109

16.73

1138

17.95

1166

19.18

 

 

11000

1118

17.64

1148

18.91

 

 

 

 

12000

1124

18.61

1155

19.91

 

 

 

 

13000

1128

19.65

1159

20.99

 

 

 

 

14000

1130

20.73

1162

22.12

 

 

 

 

15000

1132

21.80

1164

23.26

 

 

 

 

16000

1134

22.86

1166

24.39

 

 

 

 

17000

1136

23.94

1168

25.52

 

 

 

 

18000

1138

25.03

1170

26.66

 

 

 

 

19000

1141

26.15

 

 

 

 

 

 

20000

1144

27.30

 

 

 

 

 

 

21000

1147

28.50

 

 

 

 

 

 

22000

1150

29.74

 

 

 

 

 

 

22500

1152

30.38

 

 

 

 

 

 

23000

1153

31.03

 

 

 

 

 

 

24000

1157

32.36

 

 

 

 

 

 

Notes:

1.Fan performance for 40, 50, and 55 ton rooftops is identical. However, note maximum motor hp size for each size. Contact your local Trane representative for information on oversized motors.

2.Shaded areas at table extremes note non-standard Bhp or Rpm selection. Contact your local Trane representative for more information.

3.Supply fan performance table includes internal resistance of rooftop. For total static pressure determination, system external static must be added to appropriate component static pressure drops (evaporator coil, filters, optional economizer, optional exhaust fan, optional heating system, optional cooling only extended casing, optional roof curb).

4.Maximum Cfm (for UL approval) as follows:

40 Ton — 18,000 Cfm

50 Ton — 22,500 Cfm

55 Ton — 24,000 Cfm

5.Minimum motor horsepower is 7.5 hp.

6.Maximum motor horsepower as follows:

40 Ton — 30 hp

50 Ton — 30 hp

55 Ton — 30 hp

7.Maximum 7.5 hp to 15 hp motor Rpm is 1,141 Rpm, maximum 20 hp to 30 hp motor Rpm is 1,170 Rpm.

8.See RT-EB-104 for further details.

52

RT-PRC010-EN

Image 52
Contents 20 75Tons 90 130Tons Introduction American Standard IncContents Features and Benefits Standard FeaturesOptional Features Field Installed AccessoriesFeatures Summary Installation EaseEasy to Service ReliabilitySimplifyingThe Comfort System Integrated Comfort System ICSTracer control points for IntelliPak Rooftops FansWith Inlet GuideVanes Features and Benefits Optimum Building Comfort ControlVariable Frequency Drives VFD Proven DesignThroughTesting and Research Trane 3-DScroll CompressorSimple Design with 70% Fewer Parts LowTorqueVariationApplication Considerations Percent Exhaust System Barometric Relief DampersPanel C Dimensions Horizontal Discharge20 75 tons SXHF, SFHF, SLHF, SSHF, SXHF, SFHF, SLHF, Sshf UnitsTable AC-5 SXHG, SLHG, Sshg Z Dimensions Table AC-4 SXHG, SLHG, Sshg Panel a and B Dimensions2508 17.4 High Capacity Evaporator Coil Corrosive AtmospheresVentilation Override Sequences Natural Gas Heating ConsiderationsAcoustical Considerations Clearance RequirementsFigure AC-4 Unit Placement Duct DesignSelection Procedure DetermineTotalWinter Heating Load Electric Heating SystemGas Heating System Natural Gas HotWater HeatingExhaust Fan Motor Sizing Supply Fan Motor SizingAltitude Corrections Selection Procedure Model Number Description H F C1 1 567 General Data Table GD-1- General Data 20-40Tons20Ton 25Ton 30Ton 40Ton RPMFilters Table GD-2 General Data 50-75Tons 50Ton 55Ton 60Ton 70Ton 75Ton Low Ambient Option Min. Outside AirTemp90Ton 105Ton 115Ton 130Ton Table GD-3 General Data 90-130Tons50% 100% Number/Size/Type 22/FC Table GD-5 ARI Correction Multipliers Table GD-4 ARI Performance DataEER Iplv Performance Adjustment Factors Table PAF-1 Enthalpy of Saturated AIRPerformance 20Ton Data Performance 25Ton Data Performance 30Ton Data Performance 40Ton Data 345 452 265 496 183561 207 451 399 493 302 537 199 429 389 468 292 431 551Performance 50Ton Data Performance 55Ton Data Performance 60Ton Data Performance 70Ton Data AmbientTemperature FFlow Performance 75Ton Data Performance 90Ton Data Performance 105Ton Data Performance 115, 130TonsPerformance Data Table PD-24 Natural Gas Heating CapacitiesTable PD-25- Natural Gas Heating Capacities Table PD-26 Steam Heating Capacities Q/ITD1Table PD-29- 90To 130-Ton Electric Heat AirTemperature Rise Table PD-28 20 to 75-Tons Electric Heat AirTemperature RiseTable PD-30- Electric Heat KW Ranges Table PD-31- HotWater Heating Capacities Q/ITD1 20, 25Tons RPM BHPPressure 4000 1037 1225 12711364 140910 HP 1200 RPM 80% 1100 RPM 6000 883 927 968 1007 1043 1078 22.221400 RPM Wocfm 40% 1300 RPM 25 HP Inches 1200 RPM 50% 20 HP 6000 890 933 974 1012 1049 Table PD-35 Supply Fan PerformanceWITH Inletvanes 30Ton1357 20.45 Dual 18 X 18 Fans Wocfm Entrance Losses Ithout Exhaust15 HP 1200 RPM Fan Curve Limits 1000 RPM 10 HP30.47 40, 50, 55Tons32.36 40, 50, 55Tons 800 14.86 820 1161 32.63 Cfm Total Static Pressure Std 250 500 750 000Inches w.c 60, 70, 75Tons 43.8560, 70, 75Tons 14000 729 800 RPM 20 HP 70% 15 HP 27000 646 690 732 773 808 840 10.71 872 904 13.34 28000 667 710 750 791 826 10.15 85730000 708 749 787 826 10.13 861 897 12.88 928 14.40 957 15.80 98527000 1363 39.85 1388 41.68 1414 43.54 1437 45.26 1461 29000 1375 42.04 1398 43.93 1423 45.91 14451469 49.80 1491 1515 53.66 30000 1382 43.16 1406 45.18 142827000 695 734 770 805 840 904 13.44 935 14.77 28000 718 756 791 825 10.28 858891 12.90 922 14.26 952 15.65 29000 741 778 812 845 897 13.19 928 14.59 958 16.05 9871579 32000 1442 49.55 14641496 55.23 1518 57.33 1541 59.53 1565 37000 1494Performance 105,115,130Tons 1623 76.74 1640 78.95 00 R 15001100 100 900 RP25.35 26.9532.56 1233 34.40 1255 36.26 1277 38.17 46000 1138 26.67 30.40 1216 32.05 1240 33.79 1086 23.371625 76.92 1643 79.30 46000 1624 1641 79.40Table PD-44 Component Static Pressure Drops in.W.G Performance 20 -75Tons DataSFHF/G SEHF/G SLHF/G SSHF/G Performance 90-130Tons Data Table PD-45 Component Static Pressure Drops in.W.GSFHF/G SLHF/G SSHF/GTable PD-46 20-75 -Tons Supply Air Fan Drive Selections Table PD-47 90-130 -Tons Supply Air Fan Drive Selections835 39.71 859 BHP RPM885 44.08 910 46.33 934 48.32 Table PD-50 20-75Tons 100% Exhaust Fan Drive Selections Table PD-51 90-130Tons -100% Exhaust Fan Drive SelectionsTable PD-53 90-130 Tons 50% Exhaust Fan Performance Table PD-52 20-75Tons 50% Exhaust Fan Performance18.97 835 19.86 859 20.87 885 22.05 910 23.18 934 24.17 Table PD-54- 50% Exhaust Fan Drive Selections VAV Units ControlsVAV Units Only Supply Air Setpoint Reset Reset based on outdoor air temperatureReset based on zone temperature ZoneTemperature Control Unoccupied Zone Heating and CoolingCV Units Only CV UnitsHeating Gas Heating -Two-Stage Unoccupied ZoneTemperature Control Cooling and Heating Gas Heating Modulating GasElectric Heating HotWater or Steam HeatingVAV/CV Units Exhaust sequence C Purge sequence DPurge with duct pressure control E Human Interface Panel H.IGeneric Building Automation System odule Gbas Human Interface Panel Main MenuEvaporator Coil Frost Protection Occupied/Unoccupied Switching Dry BulbTemperature Control of EconomizerNight Setback Sensors Occupied/Unoccupied input on the RTMElectrical Service Sizing Dual Source Power units 200VElectrical Data Set 2. Rooftop units with Electric HeatRLA1 LRA 178 21.8 143Table ED-6 -Voltage Utilization Range 48.5 39.0 Motor Hp48.5 39.0 FLADimensional 20 75Tons Figure DD-1 20-75Ton Cooling Only Unit Dimensions Sahf Detail B Covers 40, 60, 70 and 75 TON Units20 & 25 5-8 15/ 16 24-1 3 5/ 8 1-7 9 Sahf 10’-1 7 ’-10 15/ 16 2’-0 ’-6Dimensional 90 130Tons Figure DD-5 90 130Tons Service ClearanceFigure DD-6 90 130Ton Roof Curb Dimensions Section B-B RT-PRC010-ENDimensional Field Installed SensorsConstant CV and VAV Integrated Comfort System SensorsWeights TableW-1 -Approximate OperatingWeights Lbs./KgSL/SS 14740 15380 15930 16080Options OptionsAgency Approval Ambient ControlMiscellaneous Options Electronic Zone Sensors Roof CurbMechanical Specifications GeneralSupply Fan 20 75Ton Units 90 130Ton UnitsControls Unit ControllerPermanent cleanable wire mesh option High efficiency throwaway optionPercent bag filter option Percent cartridge filter optionOutside Air General Manual outside air optionPercent modulating economizer option Ultra low-leak economizer dampers optionAccessories Heating SystemFile Number PL-RT-S*HF/S*HG-20-130TONS-PRC0010-EN-10-2001 Literature Order NumberSupersedes RT-DS-8 05/98 Stocking Location Inland-LaCrosse

RT-PRC010-EN specifications

The Trane RT-PRC010-EN is a prominent model in the line of Trane's packaged rooftop units, designed to offer efficient heating, cooling, and ventilation for commercial applications. Renowned for its robust performance, this unit integrates advanced technologies and superior engineering to meet diverse environmental needs while ensuring energy efficiency and reliability.

One of the key features of the RT-PRC010-EN is its energy-efficient operation. The unit is equipped with variable-speed fans and scroll compressors, which allow for precise control over temperature and airflow. This adaptability not only enhances comfort but also contributes to significant energy savings. The inclusion of high-efficiency cooling coils further optimizes performance, making it an excellent choice for businesses looking to lower their operational costs.

The RT-PRC010-EN model integrates smart controls that allow for seamless integration into building management systems. These controls facilitate real-time monitoring and diagnostics, enabling facility managers to maintain optimum operational efficiency and promptly address any maintenance needs. This technology minimizes downtime and extends the lifecycle of the unit.

Moreover, the unit’s construction is targeted toward resilience and durability. Built with a corrosion-resistant cabinet and extensive insulation, the RT-PRC010-EN can withstand the rigors of various climates, making it suitable for installation across different geographical locations. Its compact design allows for easy installation on rooftops, maximizing space utilization in commercial buildings.

Another standout characteristic is the unit's versatility in application. The RT-PRC010-EN can be tailored to suit a wide range of commercial settings, including retail establishments, educational institutions, and healthcare facilities. Options for various indoor and outdoor configurations enhance its adaptability to specific operational requirements.

In conclusion, the Trane RT-PRC010-EN stands out as an energy-efficient, reliable, and versatile solution for commercial heating and cooling needs. Its advanced features, smart controls, and robust design make it an ideal choice for businesses looking to enhance comfort while minimizing energy expenditures and ensuring operational reliability. Whether dealing with extreme weather conditions or managing indoor air quality concerns, this rooftop unit provides a comprehensive solution tailored to modern commercial requirements.