Trane PTAC-SVX01C-EN manual Heat pump performance, Voltage 208 230 265 Cooling data, Btu/H

Page 24

Operation

Table 18. Heat pump performance

 

 

PTHE 07

 

 

PTHE 09

 

PTHE 12

 

 

PTHE 15

 

Voltage (V)

208

230

265

208

230

265

208

230

265

208

230

265

Cooling data

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

7,200

7,400

7,200

8,900

9,100

8,700

11,700

12,000

11,700

13,300

13,600

13,600

capacity(Btu/H)

 

 

 

 

 

 

 

 

 

 

 

 

Cooling amps

2.9

2.7

2.3

3.9

3.7

3.1

5.1

4.8

4.2

6.8

6.3

5.5

(A)

 

 

 

 

 

 

 

 

 

 

 

 

EER(Btu/H watt)

12.0

12.0

12.0

11.4

11.4

10.8

11.2

11.2

11.0

9.9

9.9

9.9

Moisture

2.1

2.1

2.1

2.5

2.6

2.6

3.0

3.1

3.1

4.1

4.1

4.1

removal (Pts/h)

 

 

 

 

 

 

 

 

 

 

 

 

Heat pump

 

 

 

 

 

 

 

 

 

 

 

 

heating data

 

 

 

 

 

 

 

 

 

 

 

 

Heating capacity

5,900

6,100

6,100

7,600

7,800

7,300

9,900

10,100

10,100

12,200

12,500

12,500

(Btu/H)

 

 

 

 

 

 

 

 

 

 

 

 

Heating amps

2.6

2.5

2.1

3.4

3.2

2.6

4.3

4.0

3.5

5.8

5.4

4.7

(A)

 

 

 

 

 

 

 

 

 

 

 

 

Heating power

540

560

560

695

715

715

935

955

925

1230

1260

1260

(W)

 

 

 

 

 

 

 

 

 

 

 

 

COP (W/W)

3.2

3.2

3.2

3.2

3.2

3.0

3.1

3.1

3.2

2.9

2.9

2.9

Airflow

 

 

 

 

 

 

 

 

 

 

 

 

Indoor cfm (wet)

225

256

256

225

256

256

295

325

325

320

350

350

@0.3 esp (hi)

 

 

 

 

 

 

 

 

 

 

 

 

Indoor cfm (wet)

191

225

225

191

225

225

266

294

294

290

320

320

@0.3 esp (lo)

 

 

 

 

 

 

 

 

 

 

 

 

Indoor cfm (dry)

260

290

290

260

290

290

320

350

350

365

400

400

@0.3 esp (hi)

 

 

 

 

 

 

 

 

 

 

 

 

Indoor cfm (dry)

235

266

266

235

266

266

293

323

323

330

360

360

@0.3 esp (lo)

 

 

 

 

 

 

 

 

 

 

 

 

Electric heat

 

 

 

 

 

 

 

 

 

 

 

 

data

 

 

 

 

 

 

 

 

 

 

 

 

Heater size

 

 

 

 

 

 

 

 

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

208V

1.6

2.4

*

1.6

2.4

4.0

1.6

2.4

4.0

1.6

2.4

4.0

230V

2.0

3.0

*

2.0

3.0

5.0

2.0

3.0

5.0

2.0

3.0

5.0

265V

2.0

3.0

*

2.0

3.0

5.0

2.0

3.0

5.0

2.0

3.0

5.0

Btu/H

 

 

 

 

 

 

 

 

 

 

 

 

208V

5,500

8,200

*

5,500

8,200

13,700

5,500

8,200

13,700

5,500

8,200

13,700

230V

6,800

10,200

*

6,800

10,200

17,100

6,800

10,200

17,100

6,800

10,200

17,100

265V

6,800

10,200

*

6,800

10,200

17,100

6,800

10,200

17,100

6,800

10,200

17,100

Heating watt

 

 

 

 

 

 

 

 

 

 

 

 

208V

1,600

2,400

*

1,600

2,400

4,000

1,600

2,400

4,000

1,600

2,400

4,000

230V

2,000

3,000

*

2,000

3,000

5,000

2,000

3,000

5,000

2,000

3,000

5,000

265V

2,000

3,000

*

2,000

3,000

5,000

2,000

3,000

5,000

2,000

3,000

5,000

Heating amps

 

 

 

 

 

 

 

 

 

 

 

 

208V

7.9

11.8

*

7.9

11.8

19.7

7.9

11.8

19.7

7.9

11.8

19.7

230V

8.9

13.4

*

8.9

13.4

22.2

8.9

13.4

22.2

8.9

13.4

22.2

265V

7.7

11.6

*

7.7

11.6

19.3

7.7

11.6

19.3

7.7

11.6

19.3

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes: Certified in accordance with the Unitary Air-Conditioner Equipment Certification Program, which is based on ARI Standard 310/380.

Notes: Shaded area is rating ampere

24

PTAC-SVX01C-EN

Image 24
Contents Packaged Terminal Air Conditioner Table of Contents Model Number Description E E 0 9 0 1 * a aGeneral Information Important Environmental ConcernsOverview of Manual Responsible Refrigerant PracticesGeneral Information Pre-Installation Pre-Installation ConsiderationsChecklist Fire HazardPre-Installation Receiving ChecklistReceiving and Handling Shipping PackageUnit Dimensions Unit with wall sleeve and subbase accessory Wall SleeveUnit Dimensions Air dischargeInstallation Live Electrical ComponentsElectrical Requirements Installation Power receptacle configurationsInstallation Procedure Remove rear closureHazardous Voltage w Panel from wall sleeveInstall unit power supply BottomInstall the unit controls Voltage Options Accessory Accessory part number 115VOption 265 OptionWiring Voltage WireSpecification External Interface Size LengthConfigure the display module settings Output settingsField commissioning support Programmable Settings Set point configurationDisplay units Setpoint limitingSelection Unit Display Measure Example IP English SI MetricIndoor fan cycle configuration Energy Management SystemOccupancy arbitration for energy management Ptee manual test sequence Pthe manual test sequenceOff 10 sec Off 20 secOperation Sequence of OperationOperation Remote Fan OperationVent Control Air Discharge GrilleAir conditioner performance data Heat pump performance Voltage 208 230 265 Cooling dataElectric heat Data Heater size Btu/HCooling temperature change heat pumps Cooling temperature change air conditionersCooling amperage air conditioners Cooling amperage heat pumpsHeating total wattage input heat pumps Voltage 208 230 265Heating Btu/H Unit accessory model numbers Hydronic heat options Maintenance Maintenance ProceduresMaintenance Refrigeration System ServiceMaintenance Brazing Leak TestingHigh Temperatures Use of Pressure Regulator Valves GaugesMaintenance Evacuation Evacuation ProcedureFan Motor Overheat Charging Procedure Charging the SystemRefrigerant Line Piercing ValvesMaintenance Cooling Performance Test ThermometersSling Psychrometer Cooling Performance TestHeating Power Consumption Test Calculating procedureTesting Capacitor Resistance Resistance CheckHeater Assembly with Power OFF to the Unit and Heater Ground TestResistance Test Indoor Coil and Air ThermistorsThermistor indoor coil Resistance Rmin Rnom RmaxPower Cord Removal Component ReplacementUnit Disassembly Procedures Power cord InstallationControl Board Replacement Procedure Hazardous Voltage Removing the Outdoor Coil and Outdoor Air ThermistorsIndoor Fan and Motor Outdoor Fan and MotorTroubleshooting DiagnosticsTroubleshooting Compressor output does not energizeIndoor/remote fan outputs do not energize Outdoor fan output does not energizeRandom restart timer Explanation Reversing valve output does not energizeAuxiliary heat output does not energize Ventilation output does not energizeOutput on when the mode is off SymptomCondensate pump does not energize Control fuse is blownWiring Diagram AIR CoilWiring Diagram PVDWiring diagram 07 models PVD Energy management system Warranty Full 1st Year WarrantyFull 2nd 5th Sealed System Warranty Limited 2nd through 5th Year Functional Parts WarrantyPage PTAC-SVX01C-EN

PTAC-SVX01C-EN specifications

The Trane PTAC-SVX01C-EN is a cutting-edge Packaged Terminal Air Conditioner (PTAC) designed to provide optimal temperature control, energy efficiency, and user comfort in a variety of settings, including hotels, apartments, and office buildings. This unit stands out with its robust features and advanced technologies, making it a reliable choice for meeting diverse heating and cooling needs.

At the heart of the Trane PTAC-SVX01C-EN is its innovative design, which combines powerful performance with quiet operation. This unit utilizes a high-efficiency compressor that ensures rapid cooling and heating, providing ideal comfort regardless of the external climate. With a capacity range suitable for smaller spaces, the PTAC delivers strong performance while maintaining energy efficiency, thus reducing operational costs over time.

One of the key characteristics of the PTAC-SVX01C-EN is its user-friendly interface. The intuitive controls allow users to effortlessly adjust temperature settings, fan speeds, and modes of operation, including cooling, heating, and fan only. This flexibility enhances user comfort while optimizing energy consumption. Additionally, the unit features a programmable timer, enabling users to schedule operation according to their specific needs, further conserving energy when spaces are unoccupied.

The unit's Quiet Operation Technology minimizes noise levels, making it an ideal choice for environments where peace and quiet are paramount. This feature is particularly beneficial in hospitality settings, where guests expect a tranquil atmosphere. The PTAC is engineered to provide ample airflow while minimizing sound, creating a pleasant indoor environment.

Another standout feature of the Trane PTAC-SVX01C-EN is its advanced air filtration system. The integrated filter effectively captures dust, allergens, and other airborne particles, promoting a cleaner and healthier living environment. This is particularly essential for individuals with allergy sensitivities or respiratory issues.

Durability is also a hallmark of the PTAC-SVX01C-EN. Built with high-quality materials, it is designed to withstand the demands of continuous operation while requiring minimal maintenance. The unit's sleek and compact design allows for easy installation in various locations, ensuring versatility without sacrificing performance.

In summary, the Trane PTAC-SVX01C-EN represents a perfect blend of efficiency, comfort, and innovative technology. Its user-friendly controls, quiet operation, and advanced air filtration make it a leading choice for those seeking reliable climate control solutions in residential and commercial spaces alike. Whether for heating or cooling, the Trane PTAC-SVX01C-EN is engineered to deliver exceptional performance and lasting dependability.