Trane PTAC-SVX01C-EN manual Cooling temperature change heat pumps

Page 25

Operation

Table 19.

Cooling temperature change - air conditioners

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PTEE0701

PTEE0702

PTEE0901

PTEE0902

PTEE1201

PTEE1202

PTEE1501

PTEE1502

Room

 

Temperature across

Temperature across

Temperature across

Temperature across

 

indoor coil (T)

indoor coil (T)

indoor coil (T)

indoor coil (T)

air dry

Room air wet

 

 

 

 

 

 

 

 

bulb

bulb

Min

Max

Min

Max

Min

Max

Min

Max

 

 

 

 

 

 

 

 

 

 

 

Rating Btu/H

7200

7600

8800

9000

11700

12000

14100

14300

 

 

 

 

 

 

 

 

 

 

 

Rating cfm

230

260

240

270

300

330

315

355

 

 

 

 

 

 

 

 

 

 

 

85

1

3

2

6

1

5

1

4

 

 

 

 

 

 

 

 

 

 

90

80

8

13

11

14

9

13

8

12

 

 

 

 

 

 

 

 

 

 

75

19

22

19

22

18

22

16

20

 

 

 

 

 

 

 

 

 

 

 

70

30

33

28

30

26

30

25

27

 

 

 

 

 

 

 

 

 

 

 

80

4

9

7

11

5

10

5

8

 

 

 

 

 

 

 

 

 

 

85

75

14

19

15

18

13

18

12

16

 

 

 

 

 

 

 

 

 

 

70

23

27

23

25

21

25

20

23

 

 

 

 

 

 

 

 

 

 

 

65

34

36

31

33

29

33

28

30

 

 

 

 

 

 

 

 

 

 

 

75

9

14

11

14

9

13

8

12

 

 

 

 

 

 

 

 

 

 

80

70

18

21

18

20

15

20

15

18

 

 

 

 

 

 

 

 

 

 

65

26

29

24

27

23

26

21

24

 

 

 

 

 

 

 

 

 

 

 

60

35

36

32

33

29

33

29

30

 

 

 

 

 

 

 

 

 

 

 

70

12

16

13

16

10

15

10

14

 

 

 

 

 

 

 

 

 

 

75

65

18

22

18

21

15

20

15

19

 

 

 

 

 

 

 

 

 

 

60

25

28

23

26

21

25

20

24

 

 

 

 

 

 

 

 

 

 

 

55

31

34

28

31

26

30

26

28

 

 

 

 

 

 

 

 

 

 

70

65

12

15

12

14

9

13

9

13

 

 

 

 

 

 

 

 

 

60

17

20

16

18

13

17

13

17

 

 

 

 

 

 

 

 

 

 

 

 

55

22

24

20

22

18

21

17

21

 

 

 

 

 

 

 

 

 

 

Table 20.

Cooling temperature change - heat pumps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PTHE0701

PTHE0702

PTHE0901

PTHE0902

PTHE1201 PTHE1202

PTHE1501

PTHE1502

Room

 

Temperature across

Temperature

Temperature across

Temperature across

 

indoor coil (T)

acrossndoor coil (T)

indoor coil (T)

indoor coil (T)

airdry

Room air wet

 

 

 

 

 

 

 

 

bulb

bulb

Min

Max

Min

Max

Min

Max

Min

Max

 

 

 

 

 

 

 

 

 

 

 

rating Btu/H

7300

7600

9000

9300

11800

12000

14000

14600

 

 

 

 

 

 

 

 

 

 

 

rating cfm

195

225

240

270

315

355

315

355

 

 

 

 

 

 

 

 

 

 

 

85

1

3

2

6

1

5

1

4

 

 

 

 

 

 

 

 

 

 

90

80

8

13

11

15

10

13

8

12

 

 

 

 

 

 

 

 

 

 

75

19

22

19

22

18

22

17

20

 

 

 

 

 

 

 

 

 

 

 

70

30

33

29

30

26

30

25

28

 

 

 

 

 

 

 

 

 

 

 

80

4

9

7

11

5

10

5

9

 

 

 

 

 

 

 

 

 

 

85

75

14

19

15

18

14

18

12

16

 

 

 

 

 

 

 

 

 

 

70

23

27

23

25

21

25

21

23

 

 

 

 

 

 

 

 

 

 

 

65

33

36

31

33

30

33

28

31

 

 

 

 

 

 

 

 

 

 

 

75

9

14

11

15

10

13

8

12

 

 

 

 

 

 

 

 

 

 

80

70

18

21

18

20

16

20

16

18

 

 

 

 

 

 

 

 

 

 

65

26

29

24

27

23

26

22

25

 

 

 

 

 

 

 

 

 

 

 

60

35

36

32

33

30

33

29

31

 

 

 

 

 

 

 

 

 

 

PTAC-SVX01C-EN

25

Image 25
Contents Packaged Terminal Air Conditioner Table of Contents E E 0 9 0 1 * a a Model Number DescriptionImportant Environmental Concerns General InformationOverview of Manual Responsible Refrigerant PracticesGeneral Information Pre-Installation Considerations Pre-InstallationChecklist Fire HazardReceiving Checklist Pre-InstallationReceiving and Handling Shipping PackageUnit with wall sleeve and subbase accessory Wall Sleeve Unit DimensionsAir discharge Unit DimensionsLive Electrical Components InstallationElectrical Requirements Power receptacle configurations InstallationRemove rear closure Installation ProcedureHazardous Voltage w Panel from wall sleeveBottom Install unit power supplyVoltage Options Accessory Accessory part number 115V Install the unit controlsOption 265 OptionWire Wiring VoltageSpecification External Interface Size LengthOutput settings Configure the display module settingsField commissioning support Set point configuration Programmable SettingsSetpoint limiting Display unitsSelection Unit Display Measure Example IP English SI MetricEnergy Management System Indoor fan cycle configurationOccupancy arbitration for energy management Pthe manual test sequence Ptee manual test sequenceOff 10 sec Off 20 secSequence of Operation OperationRemote Fan Operation OperationVent Control Air Discharge GrilleAir conditioner performance data Voltage 208 230 265 Cooling data Heat pump performanceElectric heat Data Heater size Btu/HCooling temperature change air conditioners Cooling temperature change heat pumpsCooling amperage heat pumps Cooling amperage air conditionersVoltage 208 230 265 Heating total wattage input heat pumpsHeating Btu/H Unit accessory model numbers Hydronic heat options Maintenance Procedures MaintenanceRefrigeration System Service MaintenanceLeak Testing Maintenance BrazingHigh Temperatures Use of Pressure Regulator Valves GaugesEvacuation Procedure Maintenance EvacuationFan Motor Overheat Charging the System Charging ProcedureRefrigerant Line Piercing ValvesThermometers Maintenance Cooling Performance TestSling Psychrometer Cooling Performance TestCalculating procedure Heating Power Consumption TestTesting Capacitor Resistance Resistance CheckGround Test Heater Assembly with Power OFF to the Unit and HeaterResistance Test Indoor Coil and Air ThermistorsRmin Rnom Rmax Thermistor indoor coil ResistanceComponent Replacement Power Cord RemovalUnit Disassembly Procedures Power cord InstallationRemoving the Outdoor Coil and Outdoor Air Thermistors Control Board Replacement Procedure Hazardous VoltageIndoor Fan and Motor Outdoor Fan and MotorDiagnostics TroubleshootingCompressor output does not energize TroubleshootingIndoor/remote fan outputs do not energize Outdoor fan output does not energizeReversing valve output does not energize Random restart timer ExplanationAuxiliary heat output does not energize Ventilation output does not energizeSymptom Output on when the mode is offCondensate pump does not energize Control fuse is blownAIR Coil Wiring DiagramPVD Wiring DiagramWiring diagram 07 models PVD Energy management system Full 1st Year Warranty WarrantyFull 2nd 5th Sealed System Warranty Limited 2nd through 5th Year Functional Parts WarrantyPage PTAC-SVX01C-EN

PTAC-SVX01C-EN specifications

The Trane PTAC-SVX01C-EN is a cutting-edge Packaged Terminal Air Conditioner (PTAC) designed to provide optimal temperature control, energy efficiency, and user comfort in a variety of settings, including hotels, apartments, and office buildings. This unit stands out with its robust features and advanced technologies, making it a reliable choice for meeting diverse heating and cooling needs.

At the heart of the Trane PTAC-SVX01C-EN is its innovative design, which combines powerful performance with quiet operation. This unit utilizes a high-efficiency compressor that ensures rapid cooling and heating, providing ideal comfort regardless of the external climate. With a capacity range suitable for smaller spaces, the PTAC delivers strong performance while maintaining energy efficiency, thus reducing operational costs over time.

One of the key characteristics of the PTAC-SVX01C-EN is its user-friendly interface. The intuitive controls allow users to effortlessly adjust temperature settings, fan speeds, and modes of operation, including cooling, heating, and fan only. This flexibility enhances user comfort while optimizing energy consumption. Additionally, the unit features a programmable timer, enabling users to schedule operation according to their specific needs, further conserving energy when spaces are unoccupied.

The unit's Quiet Operation Technology minimizes noise levels, making it an ideal choice for environments where peace and quiet are paramount. This feature is particularly beneficial in hospitality settings, where guests expect a tranquil atmosphere. The PTAC is engineered to provide ample airflow while minimizing sound, creating a pleasant indoor environment.

Another standout feature of the Trane PTAC-SVX01C-EN is its advanced air filtration system. The integrated filter effectively captures dust, allergens, and other airborne particles, promoting a cleaner and healthier living environment. This is particularly essential for individuals with allergy sensitivities or respiratory issues.

Durability is also a hallmark of the PTAC-SVX01C-EN. Built with high-quality materials, it is designed to withstand the demands of continuous operation while requiring minimal maintenance. The unit's sleek and compact design allows for easy installation in various locations, ensuring versatility without sacrificing performance.

In summary, the Trane PTAC-SVX01C-EN represents a perfect blend of efficiency, comfort, and innovative technology. Its user-friendly controls, quiet operation, and advanced air filtration make it a leading choice for those seeking reliable climate control solutions in residential and commercial spaces alike. Whether for heating or cooling, the Trane PTAC-SVX01C-EN is engineered to deliver exceptional performance and lasting dependability.