Trane PTAC-SVX01C-EN Heating total wattage input heat pumps, Voltage 208 230 265, Heating Btu/H

Page 27

Operation

Table 23. Heating total wattage input — heat pumps

 

 

PTHE

PTHE

PTHE

PTHE

PTHE

PTHE

PTHE

PTHE

Outside air

Room air

0701

0702

0901

0902

1201

1202

1501

1502

dry-bulb

dry-bulb

Min

Max

Min

Max

Min

Max

Min

Max

 

 

 

 

 

 

 

 

 

 

 

 

520

535

670

685

940

965

1210

1235

 

85

580

620

745

790

1030

1115

1295

1435

 

 

 

 

 

 

 

 

 

 

 

80

565

600

725

775

1010

1095

1275

1410

50

 

 

 

 

 

 

 

 

 

75

550

590

710

760

990

1075

1245

1385

 

 

 

 

 

 

 

 

 

 

 

70

535

575

695

740

970

1050

1225

1360

 

 

 

 

 

 

 

 

 

 

 

65

520

560

675

720

945

1025

1200

1335

 

 

 

 

 

 

 

 

 

 

 

85

565

600

710

760

1000

1080

1240

1375

 

 

 

 

 

 

 

 

 

 

 

80

550

590

695

740

975

1060

1214

1355

45

 

 

 

 

 

 

 

 

 

75

630

570

680

730

955

1040

1190

1330

 

 

 

 

 

 

 

 

 

 

 

70

515

555

660

710

930

1010

1160

1305

 

 

 

 

 

 

 

 

 

 

 

65

500

540

640

690

910

995

1145

1280

 

 

 

 

 

 

 

 

 

 

 

85

545

580

680

725

950

1040

1185

1320

 

 

 

 

 

 

 

 

 

 

 

80

530

570

660

710

940

1020

1160

1300

40

 

 

 

 

 

 

 

 

 

75

515

555

640

690

920

1000

1135

1270

 

 

 

 

 

 

 

 

 

 

 

70

500

535

630

675

895

980

1110

1250

 

 

 

 

 

 

 

 

 

 

 

65

480

520

610

675

875

955

1090

1220

 

 

 

 

 

 

 

 

 

 

 

85

525

565

650

695

925

1010

1130

1270

 

 

 

 

 

 

 

 

 

 

 

80

510

550

630

675

900

985

1110

1240

35

 

 

 

 

 

 

 

 

 

75

500

535

610

655

880

965

1080

1220

 

 

 

 

 

 

 

 

 

 

 

70

480

520

600

645

855

940

1060

1190

 

 

 

 

 

 

 

 

 

 

 

65

465

500

580

625

940

922

1030

1265

 

 

 

 

 

 

 

 

 

 

Notes: Shaded area is rating wattage

Table 24.

Heat pump reverse cycle heating capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PTEE07

 

 

PTEE09

 

 

PTEE12

 

 

PTEE15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

208

230

265

208

230

265

208

230

265

208

230

265

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amps

 

2.5

2.4

2.4

3.4

3.2

2.6

4.3

4.0

3.5

5.7

5.3

4.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Btu/H

 

6400

6600

6600

7600

7800

8000

10100

10300

10300

12800

13100

13100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COP

 

3.6

3.6

3.6

3.2

3.2

3.4

3.3

3.3

3.3

3.0

3.0

3.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cfm (dry)

 

220

230

250

240

270

270

330

360

350

350

390

380

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

 

Btu/H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor

62

7200

7400

7400

9600

9700

9700

12800

13000

13000

15700

15800

15800

Ambient

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

6900

7100

7100

9300

9600

9600

12500

12800

12800

15000

15200

15200

 

52

6500

6700

6700

8700

9000

9000

11700

12000

12000

14200

14400

14400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rating

47

6200

6400

6400

8200

8400

8400

10900

11200

11200

13300

13500

13500

Point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

42

5900

6100

6100

7700

7900

7900

10200

10500

10500

12500

12700

12700

 

37

5600

5800

5800

7200

7400

7400

9500

9700

9700

11700

11900

11900

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32

5300

5500

5500

6700

6900

6900

9600

8900

8900

10800

11000

11000

 

27

5000

5200

5200

6200

6300

6300

7900

8200

8200

10000

10200

10200

 

24

4800

5000

5000

5800

6000

6000

7500

7800

7800

9500

9700

9700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PTAC-SVX01C-EN

27

Image 27
Contents Packaged Terminal Air Conditioner Table of Contents E E 0 9 0 1 * a a Model Number DescriptionResponsible Refrigerant Practices General InformationImportant Environmental Concerns Overview of ManualGeneral Information Fire Hazard Pre-InstallationPre-Installation Considerations ChecklistShipping Package Pre-InstallationReceiving Checklist Receiving and HandlingUnit with wall sleeve and subbase accessory Wall Sleeve Unit DimensionsAir discharge Unit DimensionsInstallation Live Electrical ComponentsElectrical Requirements Power receptacle configurations InstallationPanel from wall sleeve Installation ProcedureRemove rear closure Hazardous Voltage wBottom Install unit power supply265 Option Install the unit controlsVoltage Options Accessory Accessory part number 115V OptionExternal Interface Size Length Wiring VoltageWire SpecificationConfigure the display module settings Output settingsField commissioning support Set point configuration Programmable SettingsSI Metric Display unitsSetpoint limiting Selection Unit Display Measure Example IP EnglishIndoor fan cycle configuration Energy Management SystemOccupancy arbitration for energy management Off 20 sec Ptee manual test sequencePthe manual test sequence Off 10 secSequence of Operation OperationAir Discharge Grille OperationRemote Fan Operation Vent ControlAir conditioner performance data Btu/H Heat pump performanceVoltage 208 230 265 Cooling data Electric heat Data Heater sizeCooling temperature change air conditioners Cooling temperature change heat pumpsCooling amperage heat pumps Cooling amperage air conditionersHeating total wattage input heat pumps Voltage 208 230 265Heating Btu/H Unit accessory model numbers Hydronic heat options Maintenance Procedures MaintenanceRefrigeration System Service MaintenanceUse of Pressure Regulator Valves Gauges Maintenance BrazingLeak Testing High TemperaturesMaintenance Evacuation Evacuation ProcedureFan Motor Overheat Line Piercing Valves Charging ProcedureCharging the System RefrigerantCooling Performance Test Maintenance Cooling Performance TestThermometers Sling PsychrometerResistance Check Heating Power Consumption TestCalculating procedure Testing Capacitor ResistanceIndoor Coil and Air Thermistors Heater Assembly with Power OFF to the Unit and HeaterGround Test Resistance TestRmin Rnom Rmax Thermistor indoor coil ResistancePower cord Installation Power Cord RemovalComponent Replacement Unit Disassembly ProceduresOutdoor Fan and Motor Control Board Replacement Procedure Hazardous VoltageRemoving the Outdoor Coil and Outdoor Air Thermistors Indoor Fan and MotorDiagnostics TroubleshootingOutdoor fan output does not energize TroubleshootingCompressor output does not energize Indoor/remote fan outputs do not energizeVentilation output does not energize Random restart timer ExplanationReversing valve output does not energize Auxiliary heat output does not energizeControl fuse is blown Output on when the mode is offSymptom Condensate pump does not energizeAIR Coil Wiring DiagramPVD Wiring DiagramWiring diagram 07 models PVD Energy management system Limited 2nd through 5th Year Functional Parts Warranty WarrantyFull 1st Year Warranty Full 2nd 5th Sealed System WarrantyPage PTAC-SVX01C-EN

PTAC-SVX01C-EN specifications

The Trane PTAC-SVX01C-EN is a cutting-edge Packaged Terminal Air Conditioner (PTAC) designed to provide optimal temperature control, energy efficiency, and user comfort in a variety of settings, including hotels, apartments, and office buildings. This unit stands out with its robust features and advanced technologies, making it a reliable choice for meeting diverse heating and cooling needs.

At the heart of the Trane PTAC-SVX01C-EN is its innovative design, which combines powerful performance with quiet operation. This unit utilizes a high-efficiency compressor that ensures rapid cooling and heating, providing ideal comfort regardless of the external climate. With a capacity range suitable for smaller spaces, the PTAC delivers strong performance while maintaining energy efficiency, thus reducing operational costs over time.

One of the key characteristics of the PTAC-SVX01C-EN is its user-friendly interface. The intuitive controls allow users to effortlessly adjust temperature settings, fan speeds, and modes of operation, including cooling, heating, and fan only. This flexibility enhances user comfort while optimizing energy consumption. Additionally, the unit features a programmable timer, enabling users to schedule operation according to their specific needs, further conserving energy when spaces are unoccupied.

The unit's Quiet Operation Technology minimizes noise levels, making it an ideal choice for environments where peace and quiet are paramount. This feature is particularly beneficial in hospitality settings, where guests expect a tranquil atmosphere. The PTAC is engineered to provide ample airflow while minimizing sound, creating a pleasant indoor environment.

Another standout feature of the Trane PTAC-SVX01C-EN is its advanced air filtration system. The integrated filter effectively captures dust, allergens, and other airborne particles, promoting a cleaner and healthier living environment. This is particularly essential for individuals with allergy sensitivities or respiratory issues.

Durability is also a hallmark of the PTAC-SVX01C-EN. Built with high-quality materials, it is designed to withstand the demands of continuous operation while requiring minimal maintenance. The unit's sleek and compact design allows for easy installation in various locations, ensuring versatility without sacrificing performance.

In summary, the Trane PTAC-SVX01C-EN represents a perfect blend of efficiency, comfort, and innovative technology. Its user-friendly controls, quiet operation, and advanced air filtration make it a leading choice for those seeking reliable climate control solutions in residential and commercial spaces alike. Whether for heating or cooling, the Trane PTAC-SVX01C-EN is engineered to deliver exceptional performance and lasting dependability.