Trane PTAC-SVX01C-EN manual Wiring Diagram, Pvd

Page 46

Wiring Diagram

CP

PVD

HI

IM

OM

RVS

 

 

 

 

 

 

 

COMP

 

 

 

 

LO N

HI

YL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BR

 

 

OR

 

 

 

 

 

 

 

 

 

 

BK RD YL

 

 

 

 

 

BK

 

OR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NC

 

 

 

NO

 

 

 

 

P15

P14

P13

P12

 

P11

 

 

 

 

NO

 

 

 

COM

 

 

 

 

 

 

 

 

 

COM

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

K8 HEAT

K9 COOL

BK

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

BK

L

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cond

Vent

Fan

 

Rev Valve

 

 

 

 

 

 

 

 

 

RD

 

 

 

 

 

 

208/230

265

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

RD

 

 

 

 

 

 

 

 

 

 

 

RD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P10

P9

P8 P7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND WIRE

 

 

 

 

 

 

 

 

P4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TB2 TB1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR

COIL

 

 

 

 

F1

T1

 

 

 

RF C R W Y GHGL O VT EN

 

 

2

1

2

1

4

3

2

1

 

 

 

 

 

 

 

P3

 

P2

P1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR COIL TEMPERATURE

 

REMOTE

REMOTE

ENERGY

 

 

 

 

 

 

 

 

INDOOR COIL TEMPERATURE

 

FAN

THERMOSTAT

INPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR TEMPERATURE

 

 

RELAY

VENTILATION

REMOTE

 

 

LOCAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

 

DISPLAY

 

DISPLAY

 

 

 

 

 

 

 

8

7

6

5

4

3

2

5.0KW

1

8

7

6

5

4

3 2

3.0KW

1

 

7

 

 

 

 

 

2.0KW

8

6 5

4

3

2

1

8

7

6

5

4

3

2

1

 

 

 

 

 

 

RD

 

 

 

 

 

 

YL/GR

BK

 

 

 

 

 

 

 

WH

 

 

BL

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

2

1.0KW

 

BK

 

 

3

 

 

 

4

 

 

 

 

 

 

 

2.0KW

 

 

 

 

 

 

5

 

 

 

 

 

 

6

2.0KW

 

 

 

 

 

 

 

 

 

 

RD

 

 

TL

 

 

 

RD

 

 

TL FL

 

 

 

 

 

 

 

CP -

CONDENSATE PUMP

RD - RED

PVD - POWER VENTILATION DOOR

GR - GREEN

RVS - REVERSING VALVE

WH - WHITE

IM -

INDOOR MOTOR

BK - BLACK

OM -

OUTDOOR MOTOR

OR - ORANGE

COMP - COMPRESSOR

YL - YELLOW

 

FACTORY WIRING

BL - BLUE

 

FIELD WIRING

BR - BROWN

1)For 208/230 VAC unit, connect P8 and P10.

2)For cooling only unit, there is no outdoor temperature sensor and reversing valve.

3)For different electric heater capacity, refer to IOM for power cord selection.

4)The specs for the control board fuse are: 5 x 20mm, 250V, 315mA, fast acting.

Figure 30. 230/208V Wiring diagram (09, 12, 15 models)

46

PTAC-SVX01C-EN

Image 46
Contents Packaged Terminal Air Conditioner Table of Contents Model Number Description E E 0 9 0 1 * a aOverview of Manual General InformationImportant Environmental Concerns Responsible Refrigerant PracticesGeneral Information Checklist Pre-InstallationPre-Installation Considerations Fire HazardReceiving and Handling Pre-InstallationReceiving Checklist Shipping PackageUnit Dimensions Unit with wall sleeve and subbase accessory Wall SleeveUnit Dimensions Air dischargeLive Electrical Components InstallationElectrical Requirements Installation Power receptacle configurationsHazardous Voltage w Installation ProcedureRemove rear closure Panel from wall sleeveInstall unit power supply BottomOption Install the unit controlsVoltage Options Accessory Accessory part number 115V 265 OptionSpecification Wiring VoltageWire External Interface Size LengthOutput settings Configure the display module settingsField commissioning support Programmable Settings Set point configurationSelection Unit Display Measure Example IP English Display unitsSetpoint limiting SI MetricEnergy Management System Indoor fan cycle configurationOccupancy arbitration for energy management Off 10 sec Ptee manual test sequencePthe manual test sequence Off 20 secOperation Sequence of OperationVent Control OperationRemote Fan Operation Air Discharge GrilleAir conditioner performance data Electric heat Data Heater size Heat pump performanceVoltage 208 230 265 Cooling data Btu/HCooling temperature change heat pumps Cooling temperature change air conditionersCooling amperage air conditioners Cooling amperage heat pumpsVoltage 208 230 265 Heating total wattage input heat pumpsHeating Btu/H Unit accessory model numbers Hydronic heat options Maintenance Maintenance ProceduresMaintenance Refrigeration System ServiceHigh Temperatures Maintenance BrazingLeak Testing Use of Pressure Regulator Valves GaugesEvacuation Procedure Maintenance EvacuationFan Motor Overheat Refrigerant Charging ProcedureCharging the System Line Piercing ValvesSling Psychrometer Maintenance Cooling Performance TestThermometers Cooling Performance TestTesting Capacitor Resistance Heating Power Consumption TestCalculating procedure Resistance CheckResistance Test Heater Assembly with Power OFF to the Unit and HeaterGround Test Indoor Coil and Air ThermistorsThermistor indoor coil Resistance Rmin Rnom RmaxUnit Disassembly Procedures Power Cord RemovalComponent Replacement Power cord InstallationIndoor Fan and Motor Control Board Replacement Procedure Hazardous VoltageRemoving the Outdoor Coil and Outdoor Air Thermistors Outdoor Fan and MotorTroubleshooting DiagnosticsIndoor/remote fan outputs do not energize TroubleshootingCompressor output does not energize Outdoor fan output does not energizeAuxiliary heat output does not energize Random restart timer ExplanationReversing valve output does not energize Ventilation output does not energizeCondensate pump does not energize Output on when the mode is offSymptom Control fuse is blownWiring Diagram AIR CoilWiring Diagram PVDWiring diagram 07 models PVD Energy management system Full 2nd 5th Sealed System Warranty WarrantyFull 1st Year Warranty Limited 2nd through 5th Year Functional Parts WarrantyPage PTAC-SVX01C-EN

PTAC-SVX01C-EN specifications

The Trane PTAC-SVX01C-EN is a cutting-edge Packaged Terminal Air Conditioner (PTAC) designed to provide optimal temperature control, energy efficiency, and user comfort in a variety of settings, including hotels, apartments, and office buildings. This unit stands out with its robust features and advanced technologies, making it a reliable choice for meeting diverse heating and cooling needs.

At the heart of the Trane PTAC-SVX01C-EN is its innovative design, which combines powerful performance with quiet operation. This unit utilizes a high-efficiency compressor that ensures rapid cooling and heating, providing ideal comfort regardless of the external climate. With a capacity range suitable for smaller spaces, the PTAC delivers strong performance while maintaining energy efficiency, thus reducing operational costs over time.

One of the key characteristics of the PTAC-SVX01C-EN is its user-friendly interface. The intuitive controls allow users to effortlessly adjust temperature settings, fan speeds, and modes of operation, including cooling, heating, and fan only. This flexibility enhances user comfort while optimizing energy consumption. Additionally, the unit features a programmable timer, enabling users to schedule operation according to their specific needs, further conserving energy when spaces are unoccupied.

The unit's Quiet Operation Technology minimizes noise levels, making it an ideal choice for environments where peace and quiet are paramount. This feature is particularly beneficial in hospitality settings, where guests expect a tranquil atmosphere. The PTAC is engineered to provide ample airflow while minimizing sound, creating a pleasant indoor environment.

Another standout feature of the Trane PTAC-SVX01C-EN is its advanced air filtration system. The integrated filter effectively captures dust, allergens, and other airborne particles, promoting a cleaner and healthier living environment. This is particularly essential for individuals with allergy sensitivities or respiratory issues.

Durability is also a hallmark of the PTAC-SVX01C-EN. Built with high-quality materials, it is designed to withstand the demands of continuous operation while requiring minimal maintenance. The unit's sleek and compact design allows for easy installation in various locations, ensuring versatility without sacrificing performance.

In summary, the Trane PTAC-SVX01C-EN represents a perfect blend of efficiency, comfort, and innovative technology. Its user-friendly controls, quiet operation, and advanced air filtration make it a leading choice for those seeking reliable climate control solutions in residential and commercial spaces alike. Whether for heating or cooling, the Trane PTAC-SVX01C-EN is engineered to deliver exceptional performance and lasting dependability.