White Rodgers G1N 4R9 manual Stove Builder International Inc 1700, Léon-Harmel, Wood

Page 1
Stove Builder International Inc.

Stove Builder International Inc.

1700, Léon-Harmel

Québec(Québec)

G1N 4R9

Installation and Operating Instructions for Wood and Combined Wood-electric Furnaces

THIS MANUAL CONCERNS THE FOLLOWING FURNACES

WOOD

COMBINED ELECTRIC

PSG-2000

15 KW, 18 KW, 20 KW

PSG-3000

15 KW, 18 KW, 20 KW, 25 KW

PSG-4000

18 KW, 20 KW, 25 KW, 30 KW

PSG-4500

18 KW, 20 KW, 25 KW, 30 KW

PSG-5000

40 KW, 50 KW, 60 KW

All the instructions must be read carefully before installing and operating furnace.

CONGRATULATIONS!

You have just purchased one of the best wood or combined

wood-electric furnace on the market.

We are convinced that your furnace will provide you

with many years of comfort, safely.

Keep these instructions!

Image 1
Contents QuébecQuébec G1N 4R9 Stove Builder International Inc 1700, Léon-HarmelWOOD COMBINED ELECTRICTable of contents LIMITED LIFETIME WARRANTY 11. TROUBLESHOOTING12. DUCTS AND REGISTER MEASUREMENTS INTRODUCTION 2. SAFETY RULES1.CHIMNEY AND DRAFT GENERAL REQUIREMENTSTHEASH DRAWER GET VERY HOT W A R N I N GDONOT MANIPULATE WITH BARE HANDS ODOUR FROM THE PAINTThe drawer must be cleaned regularly 3. APPLIANCE INSTALLATIONSMOKE DETECTOR ASH DRAWERCLEARANCES TO COMBUSTIBLE MATERIALS PIPE CONNECTOR AND DAMPER24” both sides for PSG5000 WOOD FLUE PIPEUNPROPER INSTALLATION PROPER INSTALLATIONDAMPER COMBUSTION AIRELECTRICAL CONNECTION WARNING USE FEEDING WIRES SUITABLE FOR 75OCWOOD ONLY WOOD/ELECTRICWARNING USE FEEDING WIRES SUITABLE FOR 75OC Red button manual reset Thermodisk L-170ELECTRIC ELEMENT INSIDE VIEW OF THE ELECTRIC ELEMENTFAN CONTROL THERMOSTATOUTSIDE VIEW OF THE ELECTRIC ELEMENT Control system 4. OPERATING INSTRUCTIONSLIGHTING PREHEATINGexcept for lighting and maintenance PROCEDURE TO OPEN THE LOADING DOORHEATING EARLY SIGNS OF OVERFIRED FURNACELOCAL FIRE DEPARTMENT CHIMNEY FIRESMAINTENANCE OF THE EXCHANGERS 5. MAINTENANCEMAINTENANCE OF THE BLOWER MOTOR CHIMNEY MAINTENANCEDOOR GASKET MAINTENANCE 6. REPLACEMENT PARTSFILTERS GASKETWOOD-ONLYFURNACES 7. ELECTRIC DIAGRAMS FOR UNITS BUILT FROMTHERMINAL BOARD15 KW @ 30KW WOOD/ELECTRIC FURNACESBLOWER PSG5000 WOOD-ONLYFURNACES2 SPEED MOTOR20 KW @ 30KW PSG5000 WOOD/ELECTRIC FURNACES20 KW @ 30KW SWITCH 8. ELECTRIC DIAGRAMS FOR UNITS BUILT BEFOREWOOD ONLY FURNACES PSG BLOWERBLOWER WOOD ONLY FURNACES PSGMOTOR 1 SPEED15 KW @ 30KW WOOD/ELECTRIC FURNACES PSGWOOD/ELECTRIC FURNACES PSG 5000 40KW @ 60KW 20 KW @ 30KW COMMAND20 KW @ 30KW BOARD TERMINALWOOD ONLY FURNACES PSG BLOWER15 KW @ 30KW WOOD/ELECTRIC FURNACES PSG9. TECHNICAL SPECIFICATIONS COMMERCIAL AREA RESIDENTIAL AREAIMPORTANT NOTE 11. TROUBLESHOOTINGDAMPER 12. DUCTS AND REGISTER MEASUREMENTSExposed walls N.B. The main duct mustWARRANTY APPLICATION LIMITED LIFETIME WARRANTY1700, rue Léon-Harmel,Québec Québec G1N 4R9 tel. 418 527-3060fax