White Rodgers G1N 4R9 manual Appliance Installation, Smoke Detector, Ash Drawer, Ash Grate

Page 6
SMOKE DETECTOR

SMOKE DETECTOR

We highly recommend the use of a smoke detector. It must be installed at least 15 feet (4,57 m) from the appliance in order to prevent undue triggering of the detector when reloading.

ASH DRAWER

Your appliance is equipped with an ash drawer to collect ashes produced by the combustion of wood. This drawer must not be left open during combustion as this will cause over firing and serious damage to the furnace.

The drawer must be cleaned regularly.

It is important that the door and the ash drawer be kept closed while the appliance is in use. Maintain all gaskets in good condition: in case of deterioration, contact your dealer for replacement.

ASH GRATE

You must replace the ash grate if it is damaged and a replacement may be obtained from your dealer.

3. APPLIANCE INSTALLATION

UNIT LOCATION

The furnace must be installed where outside air supply is sufficient for proper combustion. In airtight houses, it might be necessary to install an outside air inlet (see details in: «3- INSTALLATION» D- COMBUSTION AIR).

The furnace must be positioned so that the connector is as short as possible in order to minimize the use of 90o elbows.

The owner must ensure a proper installation to allow a safe operation of the appliance.

6

Image 6
Contents WOOD Stove Builder International Inc 1700, Léon-HarmelQuébecQuébec G1N 4R9 COMBINED ELECTRICTable of contents 11. TROUBLESHOOTING LIMITED LIFETIME WARRANTY12. DUCTS AND REGISTER MEASUREMENTS 1.CHIMNEY AND DRAFT 2. SAFETY RULESINTRODUCTION GENERAL REQUIREMENTSDONOT MANIPULATE WITH BARE HANDS W A R N I N GTHEASH DRAWER GET VERY HOT ODOUR FROM THE PAINTSMOKE DETECTOR 3. APPLIANCE INSTALLATIONThe drawer must be cleaned regularly ASH DRAWER24” both sides for PSG5000 PIPE CONNECTOR AND DAMPERCLEARANCES TO COMBUSTIBLE MATERIALS WOOD FLUE PIPEDAMPER PROPER INSTALLATIONUNPROPER INSTALLATION COMBUSTION AIRWOOD ONLY WARNING USE FEEDING WIRES SUITABLE FOR 75OCELECTRICAL CONNECTION WOOD/ELECTRICELECTRIC ELEMENT Red button manual reset Thermodisk L-170WARNING USE FEEDING WIRES SUITABLE FOR 75OC INSIDE VIEW OF THE ELECTRIC ELEMENTTHERMOSTAT FAN CONTROLOUTSIDE VIEW OF THE ELECTRIC ELEMENT LIGHTING 4. OPERATING INSTRUCTIONSControl system PREHEATINGHEATING PROCEDURE TO OPEN THE LOADING DOORexcept for lighting and maintenance EARLY SIGNS OF OVERFIRED FURNACECHIMNEY FIRES LOCAL FIRE DEPARTMENTMAINTENANCE OF THE BLOWER MOTOR 5. MAINTENANCEMAINTENANCE OF THE EXCHANGERS CHIMNEY MAINTENANCEFILTERS 6. REPLACEMENT PARTSDOOR GASKET MAINTENANCE GASKETTHERMINAL 7. ELECTRIC DIAGRAMS FOR UNITS BUILT FROMWOOD-ONLYFURNACES BOARDWOOD/ELECTRIC FURNACES 15 KW @ 30KW2 SPEED PSG5000 WOOD-ONLYFURNACESBLOWER MOTORPSG5000 WOOD/ELECTRIC FURNACES 20 KW @ 30KW20 KW @ 30KW WOOD ONLY FURNACES PSG 8. ELECTRIC DIAGRAMS FOR UNITS BUILT BEFORESWITCH BLOWERMOTOR WOOD ONLY FURNACES PSGBLOWER 1 SPEEDWOOD/ELECTRIC FURNACES PSG 15 KW @ 30KW20 KW @ 30KW COMMAND WOOD/ELECTRIC FURNACES PSG 5000 40KW @ 60KW20 KW @ 30KW WOOD ONLY FURNACES PSG TERMINALBOARD BLOWERWOOD/ELECTRIC FURNACES PSG 15 KW @ 30KW9. TECHNICAL SPECIFICATIONS RESIDENTIAL AREA COMMERCIAL AREA11. TROUBLESHOOTING IMPORTANT NOTEExposed walls 12. DUCTS AND REGISTER MEASUREMENTSDAMPER N.B. The main duct must1700, rue Léon-Harmel,Québec Québec G1N 4R9 LIMITED LIFETIME WARRANTYWARRANTY APPLICATION tel. 418 527-3060fax