White Rodgers G1N 4R9 manual Clearances To Combustible Materials, Pipe Connector And Damper

Page 7
CLEARANCES TO COMBUSTIBLE MATERIALS

CLEARANCES TO COMBUSTIBLE MATERIALS

N.B. This appliance must be installed in accordance with the instructions on the unit’s certification.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS FOR PSG FURNACES

2”

24” both sides for

PSG5000

N.B. THE AIR RETURN CONDUITS SHOULD BE AT LEAST EQUAL TO THE COLD AIR PLENUM DIMENSIONS.

PIPE CONNECTOR AND DAMPER

Before proceeding to connection, remove all accessories such as: scraper, shovel and poker in the evacuation pipe of the furnace.

A 6” diameter chimney listed for use with wood burning heating appliances is recommended for the PSG2000, 7” for PSG3000-4000 and 8” for the others models. Install the barometric control provided with the furnace. Never install a manual damper.

WOOD FLUE PIPE

7

OIL FLUE

PIPE

(OPTION)

MAIN

COLLECTOR

Image 7
Contents COMBINED ELECTRIC Stove Builder International Inc 1700, Léon-HarmelQuébecQuébec G1N 4R9 WOODTable of contents LIMITED LIFETIME WARRANTY 11. TROUBLESHOOTING12. DUCTS AND REGISTER MEASUREMENTS GENERAL REQUIREMENTS 2. SAFETY RULESINTRODUCTION 1.CHIMNEY AND DRAFTODOUR FROM THE PAINT W A R N I N GTHEASH DRAWER GET VERY HOT DONOT MANIPULATE WITH BARE HANDSASH DRAWER 3. APPLIANCE INSTALLATIONThe drawer must be cleaned regularly SMOKE DETECTORWOOD FLUE PIPE PIPE CONNECTOR AND DAMPERCLEARANCES TO COMBUSTIBLE MATERIALS 24” both sides for PSG5000COMBUSTION AIR PROPER INSTALLATIONUNPROPER INSTALLATION DAMPERWOOD/ELECTRIC WARNING USE FEEDING WIRES SUITABLE FOR 75OCELECTRICAL CONNECTION WOOD ONLYINSIDE VIEW OF THE ELECTRIC ELEMENT Red button manual reset Thermodisk L-170WARNING USE FEEDING WIRES SUITABLE FOR 75OC ELECTRIC ELEMENTFAN CONTROL THERMOSTATOUTSIDE VIEW OF THE ELECTRIC ELEMENT PREHEATING 4. OPERATING INSTRUCTIONSControl system LIGHTINGEARLY SIGNS OF OVERFIRED FURNACE PROCEDURE TO OPEN THE LOADING DOORexcept for lighting and maintenance HEATINGLOCAL FIRE DEPARTMENT CHIMNEY FIRESCHIMNEY MAINTENANCE 5. MAINTENANCEMAINTENANCE OF THE EXCHANGERS MAINTENANCE OF THE BLOWER MOTORGASKET 6. REPLACEMENT PARTSDOOR GASKET MAINTENANCE FILTERSBOARD 7. ELECTRIC DIAGRAMS FOR UNITS BUILT FROMWOOD-ONLYFURNACES THERMINAL15 KW @ 30KW WOOD/ELECTRIC FURNACESMOTOR PSG5000 WOOD-ONLYFURNACESBLOWER 2 SPEED20 KW @ 30KW PSG5000 WOOD/ELECTRIC FURNACES20 KW @ 30KW BLOWER 8. ELECTRIC DIAGRAMS FOR UNITS BUILT BEFORESWITCH WOOD ONLY FURNACES PSG1 SPEED WOOD ONLY FURNACES PSGBLOWER MOTOR15 KW @ 30KW WOOD/ELECTRIC FURNACES PSGWOOD/ELECTRIC FURNACES PSG 5000 40KW @ 60KW 20 KW @ 30KW COMMAND20 KW @ 30KW BLOWER TERMINALBOARD WOOD ONLY FURNACES PSG15 KW @ 30KW WOOD/ELECTRIC FURNACES PSG9. TECHNICAL SPECIFICATIONS COMMERCIAL AREA RESIDENTIAL AREAIMPORTANT NOTE 11. TROUBLESHOOTINGN.B. The main duct must 12. DUCTS AND REGISTER MEASUREMENTSDAMPER Exposed wallstel. 418 527-3060fax LIMITED LIFETIME WARRANTYWARRANTY APPLICATION 1700, rue Léon-Harmel,Québec Québec G1N 4R9