White Rodgers G1N 4R9 manual Operating Instructions, Control system, Lighting, Preheating

Page 12

4. OPERATING INSTRUCTIONS

Control system

On the wood furnaces only, the thermostat controls the air inlet damper. When the thermostat calls for heat, the damper opens and the fire burns up. When the furnace gets hot enough, the combined limit control activates the blower motor at the speed selected for wood heating.

The chain that links the air inlet damper to the motor must have a play of 1/8 inch. When there is no call for heat, the air inlet damper must be completely closed and the chain must be affixed to the servo-motor at “8 o’clock”. *

*(With all reserve on the minimum air to be increased depending on the type and quality of the combustible).

LIGHTING:

1. Open the door

Note: In the case that there is a bed of coals in the bottom of the furnace, go to step b) Pre-heating.

2.Place one or two dry kindlings at the front of the furnace.

3.Place newspaper strips on top of the kindlings.

4.Cover the newspaper with more kindlings and small pieces of dry wood.

5.Add newspaper strips, then light the fire a low as possible and leave the door 1/2" (13 mm) opened. If you fail lighting the fire, you might experience a back draft through the air inlets.

PREHEATING

1.Once the kindling is well ignited or the coals revived, put 2 or 3 fire logs in such a way that the flames can interlace between the logs then close the door. It is important to respect these loading sequences so that the wood will burn from the front to the back of the furnace.

2.Wait 15 to 20 minutes, then proceed with loading the furnace.

12

Image 12
Contents Stove Builder International Inc 1700, Léon-Harmel QuébecQuébec G1N 4R9WOOD COMBINED ELECTRICTable of contents 11. TROUBLESHOOTING LIMITED LIFETIME WARRANTY12. DUCTS AND REGISTER MEASUREMENTS 2. SAFETY RULES INTRODUCTION1.CHIMNEY AND DRAFT GENERAL REQUIREMENTSW A R N I N G THEASH DRAWER GET VERY HOTDONOT MANIPULATE WITH BARE HANDS ODOUR FROM THE PAINT3. APPLIANCE INSTALLATION The drawer must be cleaned regularlySMOKE DETECTOR ASH DRAWERPIPE CONNECTOR AND DAMPER CLEARANCES TO COMBUSTIBLE MATERIALS24” both sides for PSG5000 WOOD FLUE PIPEPROPER INSTALLATION UNPROPER INSTALLATIONDAMPER COMBUSTION AIRWARNING USE FEEDING WIRES SUITABLE FOR 75OC ELECTRICAL CONNECTIONWOOD ONLY WOOD/ELECTRICRed button manual reset Thermodisk L-170 WARNING USE FEEDING WIRES SUITABLE FOR 75OCELECTRIC ELEMENT INSIDE VIEW OF THE ELECTRIC ELEMENTTHERMOSTAT FAN CONTROLOUTSIDE VIEW OF THE ELECTRIC ELEMENT 4. OPERATING INSTRUCTIONS Control systemLIGHTING PREHEATINGPROCEDURE TO OPEN THE LOADING DOOR except for lighting and maintenanceHEATING EARLY SIGNS OF OVERFIRED FURNACECHIMNEY FIRES LOCAL FIRE DEPARTMENT5. MAINTENANCE MAINTENANCE OF THE EXCHANGERSMAINTENANCE OF THE BLOWER MOTOR CHIMNEY MAINTENANCE6. REPLACEMENT PARTS DOOR GASKET MAINTENANCEFILTERS GASKET7. ELECTRIC DIAGRAMS FOR UNITS BUILT FROM WOOD-ONLYFURNACESTHERMINAL BOARDWOOD/ELECTRIC FURNACES 15 KW @ 30KWPSG5000 WOOD-ONLYFURNACES BLOWER2 SPEED MOTORPSG5000 WOOD/ELECTRIC FURNACES 20 KW @ 30KW20 KW @ 30KW 8. ELECTRIC DIAGRAMS FOR UNITS BUILT BEFORE SWITCHWOOD ONLY FURNACES PSG BLOWERWOOD ONLY FURNACES PSG BLOWERMOTOR 1 SPEEDWOOD/ELECTRIC FURNACES PSG 15 KW @ 30KW20 KW @ 30KW COMMAND WOOD/ELECTRIC FURNACES PSG 5000 40KW @ 60KW20 KW @ 30KW TERMINAL BOARDWOOD ONLY FURNACES PSG BLOWERWOOD/ELECTRIC FURNACES PSG 15 KW @ 30KW9. TECHNICAL SPECIFICATIONS RESIDENTIAL AREA COMMERCIAL AREA11. TROUBLESHOOTING IMPORTANT NOTE12. DUCTS AND REGISTER MEASUREMENTS DAMPERExposed walls N.B. The main duct mustLIMITED LIFETIME WARRANTY WARRANTY APPLICATION1700, rue Léon-Harmel,Québec Québec G1N 4R9 tel. 418 527-3060fax