Whenever a high rate of smoke is noticed in the room, you must:

1.Open doors and windows.

2.Make sure the furnace door is closed as well as the damper (if necessary, lower the thermostat starting point or undo the chain of the damper and close manually the barometric draft control).

3.When the furnace has cooled down, inspect the chimney to detect obstructions and consult a specialist to determine the cause.

CARBON MONOXYDE IS A LETHAL GAS (ODOURLESS AND COLOURLESS), WHICH YOU MUST BEWARE OF.

CHIMNEY FIRES

This might occur when the fire gets extremely hot. Burning cardboard, branches or pieces of wood can ignite the creosote residue accumulated in the evacuation flue system. The usual signs are:

1.Rumbling

2.The flue gets extremely hot

3.Flames are coming out of the chimney

In case of a chimney fire, first call your local fire department and sprinkle the roof around the chimney with water.

Make sure that the furnace door is closed as well as the damper (if necessary, lower the thermostat starting point or release the chain from the damper and CLOSE the barometric draft control manually).

If the fire gets uncontrollable due to an improper use or because the draft is too strong, follow the same procedure as in a chimney fire except that you will have to OPEN manually the barometric draft control.

LOCAL FIRE DEPARTMENT.

Phone number: ___________________________________

14

Image 14
Contents WOOD Stove Builder International Inc 1700, Léon-HarmelQuébecQuébec G1N 4R9 COMBINED ELECTRICTable of contents 12. DUCTS AND REGISTER MEASUREMENTS 11. TROUBLESHOOTINGLIMITED LIFETIME WARRANTY 1.CHIMNEY AND DRAFT 2. SAFETY RULESINTRODUCTION GENERAL REQUIREMENTSDONOT MANIPULATE WITH BARE HANDS W A R N I N GTHEASH DRAWER GET VERY HOT ODOUR FROM THE PAINTSMOKE DETECTOR 3. APPLIANCE INSTALLATIONThe drawer must be cleaned regularly ASH DRAWER24” both sides for PSG5000 PIPE CONNECTOR AND DAMPERCLEARANCES TO COMBUSTIBLE MATERIALS WOOD FLUE PIPEDAMPER PROPER INSTALLATIONUNPROPER INSTALLATION COMBUSTION AIRWOOD ONLY WARNING USE FEEDING WIRES SUITABLE FOR 75OCELECTRICAL CONNECTION WOOD/ELECTRICELECTRIC ELEMENT Red button manual reset Thermodisk L-170WARNING USE FEEDING WIRES SUITABLE FOR 75OC INSIDE VIEW OF THE ELECTRIC ELEMENTOUTSIDE VIEW OF THE ELECTRIC ELEMENT THERMOSTATFAN CONTROL LIGHTING 4. OPERATING INSTRUCTIONSControl system PREHEATINGHEATING PROCEDURE TO OPEN THE LOADING DOORexcept for lighting and maintenance EARLY SIGNS OF OVERFIRED FURNACECHIMNEY FIRES LOCAL FIRE DEPARTMENTMAINTENANCE OF THE BLOWER MOTOR 5. MAINTENANCEMAINTENANCE OF THE EXCHANGERS CHIMNEY MAINTENANCEFILTERS 6. REPLACEMENT PARTSDOOR GASKET MAINTENANCE GASKETTHERMINAL 7. ELECTRIC DIAGRAMS FOR UNITS BUILT FROMWOOD-ONLYFURNACES BOARDWOOD/ELECTRIC FURNACES 15 KW @ 30KW2 SPEED PSG5000 WOOD-ONLYFURNACESBLOWER MOTOR20 KW @ 30KW PSG5000 WOOD/ELECTRIC FURNACES20 KW @ 30KW WOOD ONLY FURNACES PSG 8. ELECTRIC DIAGRAMS FOR UNITS BUILT BEFORESWITCH BLOWERMOTOR WOOD ONLY FURNACES PSGBLOWER 1 SPEEDWOOD/ELECTRIC FURNACES PSG 15 KW @ 30KW20 KW @ 30KW 20 KW @ 30KW COMMANDWOOD/ELECTRIC FURNACES PSG 5000 40KW @ 60KW WOOD ONLY FURNACES PSG TERMINALBOARD BLOWERWOOD/ELECTRIC FURNACES PSG 15 KW @ 30KW9. TECHNICAL SPECIFICATIONS RESIDENTIAL AREA COMMERCIAL AREA11. TROUBLESHOOTING IMPORTANT NOTEExposed walls 12. DUCTS AND REGISTER MEASUREMENTSDAMPER N.B. The main duct must1700, rue Léon-Harmel,Québec Québec G1N 4R9 LIMITED LIFETIME WARRANTYWARRANTY APPLICATION tel. 418 527-3060fax