White Rodgers G1N 4R9 manual Inside View Of The Electric Element

Page 10
ELECTRIC ELEMENT

The switch located on the fan limit control activates the blower at high speed, in either automatic or manual (continuous operation) modes.

The switch located on the electric unit controls low speed operation, in either ON (continuous operation) or OFF modes (PSG 3000 or PSG 4000 models only).

WARNING: USE FEEDING WIRES SUITABLE FOR 75OC

*(With all reserves on the minimum combustion air to be increased depending on the type and quality of the combustible).

ELECTRIC ELEMENT

The WOOD / ELECTRIC combined model is installed with two thermostats: one thermostat controls the electric heating, the other one controls the wood heating. With this system, the electric heating has priority over the wood heating. When the thermostat activates the electric heating, the air inlet closes down (if opened), the blower starts and the electric elements are successively activated per block of 5 kW. The system might be equipped with an exterior thermostat which will allow the last block of elements (5 kW) to start up only when the outside temperature is cold enough. This will reduce the power of the systems by 5 kW during mild temperature for more comfort.

When the call for electric heating is completed, the wood system will take over if the starting point of the wood system is superior to the electric system.

So, in normal bi-energy use, you must set the wood system thermostat 2o to 3o higher than the electric system thermostat.

Take note that this furnace is equipped with a four speed motor. Aside from low speed, three choices are available: medium-low, medium-high or high.

If the temperature of the element exceeds the limit allowed, the thermodisk will disengage the element. For reactivation, press the red button “manual reset” of the thermodisk L-170 and find out why the temperature limit has been exceeded (static pressure too high, fan breakage, dirty filter, etc.)

INSIDE VIEW OF THE ELECTRIC ELEMENT

Red button manual reset

Thermodisk L-170

10

Image 10
Contents WOOD Stove Builder International Inc 1700, Léon-HarmelQuébecQuébec G1N 4R9 COMBINED ELECTRICTable of contents LIMITED LIFETIME WARRANTY 11. TROUBLESHOOTING12. DUCTS AND REGISTER MEASUREMENTS 1.CHIMNEY AND DRAFT 2. SAFETY RULESINTRODUCTION GENERAL REQUIREMENTSDONOT MANIPULATE WITH BARE HANDS W A R N I N GTHEASH DRAWER GET VERY HOT ODOUR FROM THE PAINTSMOKE DETECTOR 3. APPLIANCE INSTALLATIONThe drawer must be cleaned regularly ASH DRAWER24” both sides for PSG5000 PIPE CONNECTOR AND DAMPERCLEARANCES TO COMBUSTIBLE MATERIALS WOOD FLUE PIPEDAMPER PROPER INSTALLATIONUNPROPER INSTALLATION COMBUSTION AIRWOOD ONLY WARNING USE FEEDING WIRES SUITABLE FOR 75OCELECTRICAL CONNECTION WOOD/ELECTRICELECTRIC ELEMENT Red button manual reset Thermodisk L-170WARNING USE FEEDING WIRES SUITABLE FOR 75OC INSIDE VIEW OF THE ELECTRIC ELEMENTFAN CONTROL THERMOSTATOUTSIDE VIEW OF THE ELECTRIC ELEMENT LIGHTING 4. OPERATING INSTRUCTIONSControl system PREHEATINGHEATING PROCEDURE TO OPEN THE LOADING DOORexcept for lighting and maintenance EARLY SIGNS OF OVERFIRED FURNACECHIMNEY FIRES LOCAL FIRE DEPARTMENTMAINTENANCE OF THE BLOWER MOTOR 5. MAINTENANCEMAINTENANCE OF THE EXCHANGERS CHIMNEY MAINTENANCEFILTERS 6. REPLACEMENT PARTSDOOR GASKET MAINTENANCE GASKETTHERMINAL 7. ELECTRIC DIAGRAMS FOR UNITS BUILT FROMWOOD-ONLYFURNACES BOARDWOOD/ELECTRIC FURNACES 15 KW @ 30KW2 SPEED PSG5000 WOOD-ONLYFURNACESBLOWER MOTOR20 KW @ 30KW PSG5000 WOOD/ELECTRIC FURNACES20 KW @ 30KW WOOD ONLY FURNACES PSG 8. ELECTRIC DIAGRAMS FOR UNITS BUILT BEFORESWITCH BLOWERMOTOR WOOD ONLY FURNACES PSGBLOWER 1 SPEEDWOOD/ELECTRIC FURNACES PSG 15 KW @ 30KWWOOD/ELECTRIC FURNACES PSG 5000 40KW @ 60KW 20 KW @ 30KW COMMAND20 KW @ 30KW WOOD ONLY FURNACES PSG TERMINALBOARD BLOWERWOOD/ELECTRIC FURNACES PSG 15 KW @ 30KW9. TECHNICAL SPECIFICATIONS RESIDENTIAL AREA COMMERCIAL AREA11. TROUBLESHOOTING IMPORTANT NOTEExposed walls 12. DUCTS AND REGISTER MEASUREMENTSDAMPER N.B. The main duct must1700, rue Léon-Harmel,Québec Québec G1N 4R9 LIMITED LIFETIME WARRANTYWARRANTY APPLICATION tel. 418 527-3060fax