ELECTRICAL CONNECTION

NOTE:

It is recommended to install an outside air inlet of minimum 4” diameter in the room where the heating appliance is installed (see drawing below). To do so, it is preferable to choose a wall which is not exposed to extreme winds, according to the conditions surrounding your house.

Insulated conduit full lenght

Free air

Fresh air

intake

entry

 

Exterior wall

N.B. The owner of the furnace is responsible for the room salubrity in case of negative pressure or temporary negative pressure.

ELECTRICAL CONNECTION

The following instructions do not supersede the local code.

WOOD ONLY

Installed limit control on support provided on proper location of the appliance (two holes are predrilled on the edge of the furnace), and connected to the electrical box along with the transformer. Install the servo-motor on the front facade above the door, on the right side (use pre-drilled holes). The chain that links the air inlet latch to the motor must have a play of 1/8 in. When there is no call for heat, the air inlet latch must be completely shut and the chain must be affixed to the servo-motor at “8 o’clock”. *

The switch located on the fan limit control activates high speed operation, in either automatic or manual (continuous operation) modes.

The switch located on the electric unit controls low speed operation, in either ON (continuous operation) or OFF modes.

WARNING: USE FEEDING WIRES SUITABLE FOR 75OC

WOOD/ELECTRIC

The limit control is a manual reset thermostatic captor and is located directly inside the electric element (see WIRING DIAGRAMS). The electric elements must be installed as shown on the diagram. Install the combined limit control on the support provided, at the determined location. The connections must conform to the diagram.

Install the servo-motor on the front façade above the door, on the right side (use pre-drilled holes). The chain that links the air inlet latch to the motor must have a play of 1/8 in. When there is no call for heat, the air inlet latch must be completely shut and the chain must be affixed to the servo-motor at “8 o’clock”. *

9

Image 9
Contents QuébecQuébec G1N 4R9 Stove Builder International Inc 1700, Léon-HarmelWOOD COMBINED ELECTRICTable of contents 11. TROUBLESHOOTING LIMITED LIFETIME WARRANTY12. DUCTS AND REGISTER MEASUREMENTS INTRODUCTION 2. SAFETY RULES1.CHIMNEY AND DRAFT GENERAL REQUIREMENTSTHEASH DRAWER GET VERY HOT W A R N I N GDONOT MANIPULATE WITH BARE HANDS ODOUR FROM THE PAINTThe drawer must be cleaned regularly 3. APPLIANCE INSTALLATIONSMOKE DETECTOR ASH DRAWERCLEARANCES TO COMBUSTIBLE MATERIALS PIPE CONNECTOR AND DAMPER24” both sides for PSG5000 WOOD FLUE PIPEUNPROPER INSTALLATION PROPER INSTALLATIONDAMPER COMBUSTION AIRELECTRICAL CONNECTION WARNING USE FEEDING WIRES SUITABLE FOR 75OCWOOD ONLY WOOD/ELECTRICWARNING USE FEEDING WIRES SUITABLE FOR 75OC Red button manual reset Thermodisk L-170ELECTRIC ELEMENT INSIDE VIEW OF THE ELECTRIC ELEMENTTHERMOSTAT FAN CONTROLOUTSIDE VIEW OF THE ELECTRIC ELEMENT Control system 4. OPERATING INSTRUCTIONSLIGHTING PREHEATINGexcept for lighting and maintenance PROCEDURE TO OPEN THE LOADING DOORHEATING EARLY SIGNS OF OVERFIRED FURNACELOCAL FIRE DEPARTMENT CHIMNEY FIRESMAINTENANCE OF THE EXCHANGERS 5. MAINTENANCEMAINTENANCE OF THE BLOWER MOTOR CHIMNEY MAINTENANCEDOOR GASKET MAINTENANCE 6. REPLACEMENT PARTSFILTERS GASKETWOOD-ONLYFURNACES 7. ELECTRIC DIAGRAMS FOR UNITS BUILT FROMTHERMINAL BOARD15 KW @ 30KW WOOD/ELECTRIC FURNACESBLOWER PSG5000 WOOD-ONLYFURNACES2 SPEED MOTORPSG5000 WOOD/ELECTRIC FURNACES 20 KW @ 30KW20 KW @ 30KW SWITCH 8. ELECTRIC DIAGRAMS FOR UNITS BUILT BEFOREWOOD ONLY FURNACES PSG BLOWERBLOWER WOOD ONLY FURNACES PSGMOTOR 1 SPEED15 KW @ 30KW WOOD/ELECTRIC FURNACES PSG20 KW @ 30KW COMMAND WOOD/ELECTRIC FURNACES PSG 5000 40KW @ 60KW20 KW @ 30KW BOARD TERMINALWOOD ONLY FURNACES PSG BLOWER15 KW @ 30KW WOOD/ELECTRIC FURNACES PSG9. TECHNICAL SPECIFICATIONS COMMERCIAL AREA RESIDENTIAL AREAIMPORTANT NOTE 11. TROUBLESHOOTINGDAMPER 12. DUCTS AND REGISTER MEASUREMENTSExposed walls N.B. The main duct mustWARRANTY APPLICATION LIMITED LIFETIME WARRANTY1700, rue Léon-Harmel,Québec Québec G1N 4R9 tel. 418 527-3060fax