Solution 64 User Guide
2.Use the [↑] and [↓] keys to select the user that you want to add the RF keyfob ID, then press [OK] to select. Alternatively, you can enter the user number you, then press [OK].
The keypad will prompt you to enter the RF keyfob ID number:
Enter keyfob RFid for U016 User 16 Name 000000000
Press OK or MENU
3.Enter the RF Keyfob ID Number
4.Press [OK] to save and exit, or press [MENU] to exit without saving.
Access > RF Keyfob >
Delete Keyfob | MENU |
This menu allows the security installer or a master user to delete the RF keyfob ID that has been assigned to a user.
Enter programming mode (PIN + MENU) then,
1.Enter [MENU] + [1] + [3] + [1].
A list of users will display on the keypad.
U001 JOHN SMITH
U002 DEBBIE SMITH
U003 USER 3 NAME
PRESS , OK or MENU
2.Use the [↑] and [↓] keys to select the user that you want to delete the keyfob, then press [OK] to select. Alternatively, you can enter the user number, then press [OK].
OK to delete Keyfob for U002 Debbie Smith 009553507
Press OK or MENU
3.Press [OK] to delete the RF Keyfob ID number and exit, or press [MENU] to exit without saving.
Access > User Properties >
User Name | MENU |
This menu allows the master user to program the user’s name. A maximum of 16 characters can be entered.
Enter programming mode (PIN + MENU) then,
1.Enter [MENU] + [1] + [4] + [0].
A list of users will display on the keypad.
U001 JOHN SMITH
U002 DEBBIE SMITH
U003 USER 3 NAME
Press OK or MENU
2.To program the user name, use the [↑] and [↓] keys to select the user that you want to program, then press [OK] to select. Alternatively, you can enter the user number you want to program, then press [OK].
The keypad will display the current user name.
User Name U001
User 1 Name
Press ◄► OK to SAVE
3.Use the [←] and [→] keys to scroll the cursor left and right across the user name text. Use the [↑] and [↓] keys to scroll through the different characters available. To clear all text from the cursor position to the right, press the [OFF] key.
4.When the user name is complete, press [OK] to save and exit, or press [MENU] to exit without saving.
Access > User Properties >
Area Assignment | MENU |
This menu allows the master user to program which areas (1 to 8) a user can access. Each user can be assigned to one or multiple areas. The master user is restricted and can only assign another user to any one or multiple areas that the master user has been assigned to. At factory default, each user is assigned to operate Area 1.
Enter programming mode (PIN + MENU) then,
1.Enter [MENU] + [1] + [4] + [1].
A list of users will display on the keypad.
2.To assign areas to a user, use the [↑] and [↓] keys to select the user that you want to program, then press [OK] to select. Alternatively, you can enter the user number you want to program, then press [OK].
The keypad will display which areas the user has been assigned to.
Area 1
Area 2
Area 3
Press OK ON OFF MENU
3.Use the [↑] and [↓] keys to select the area that you want to assign to the user. Press the [ON] key to assign the user to the area (√ will display) or press the [OFF] key to disable the user from the corresponding area (√ will no longer display).
4.Repeat Step 3 until you have assigned the user to all areas that are required.
5.Press [OK] to save and exit, or press [MENU] to exit without saving.
Timer Groups
Timer Groups are used to restrict users from operating doors outside given times, days or holidays. To do this you need to create a time group, then assign one or more schedules to the
12 | Bosch Security Systems |
09/06