Set Part 2 Zones

Inputs > Commands >

Set Part 2 Zones

MENU 3-0-4

This menu allows you to program which zones are to be monitored when an area has been turned Part 2 On.

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [3] + [0] + [4].

A list of areas will display on the keypad.

2.Use the [] and [] keys to select the area that you want to program zones for Part 2 On, then press [OK]. Alternatively, you can enter the area number that you want to program Part 2 On zones, then press [OK].

The keypad will list all zones that can be programmed for Part 2 On. A ‘’ displayed on the right side of the zone name indicates that the zone is already bypassed.

Z001 Zone 1 Name

Z002 Zone 2 Name

Z003 Zone 3 Name

Press  OK or MENU

3.Use the [] and [] keys to select the zone that you want to set for Part 2, then press [OK]. Alternatively, you can enter the zone number that you want to set for Part 2, then press [OK].

If the zone is not programmed for Part 2, the keypad will prompt:

Zone 1 Z001

Is not a PART2 Zone,

To Enable, Press ON.

To Go Back Press OK

If the zone is programmed for Part 2, the keypad will prompt:

Zone 1 Z001

Is a PART2 Zone,

To remove, Press OFF.

To Go Back Press OK

4.Press [ON] to monitor the zone when the area is turned Part 2 On, or press [OFF] so that you do not monitor the zone when the area is turned Part 2 On.

5.Press [OK] to save and exit, or press [MENU] to exit without saving.

 

Solution 64 User Guide

Inputs > Commands >

 

 

Smoke Sensor Reset

 

MENU 3-0-5

This menu allows you to reset smoke sensors.

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [3] + [0] + [5].

A list of different areas will display on the keypad.

2.Use the [] and [] keys to select the area that you want to reset the smoke detectors, then press [OK] to select. Alternatively, you can enter the area number, then press [OK].

The keypad will display the following:

Smoke detector reset in

Progress. Please wait

3.The keypad will automatically return to the menu when all smoke detectors in the area has been reset.

Inputs > Zone Properties >

Zone Name

MENU 3-1-0

This menu allows you to program up to 16 characters for the name of each zone.

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [3] + [1] + [0].

A list of different zones will display on the keypad.

2.Use the [] and [] keys to select the zone name that you want to change, then press [OK] to select. Alternatively, you can enter the zone number, then press [OK].

The keypad will display the following:

Zone Name Z001

Zone 1 Name

Press ◄► OK to SAVE

3.Use the [] and [] keys to scroll the cursor left and right across the zone name text. Use the [] and [] keys to scroll through the different characters available. To clear all text from the cursor position to the right, press the [OFF] key.

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

Bosch Security Systems

 

09/06

 

BLCC110U

17

 

 

Image 17
Contents Security System SolutionTrademarks Copyright NoticeNotice of Liability Telepermit NoteContents Program Menu Tree I ntroduc tion FeaturesUser’s Guide Area 3 - Administration Area 4 - DispatchAbout the Keypad Reporting Alarmsfor 2 sec for 2 secMeaning IconMeaning Basic System Operation Change Own PIN System ProgrammingCharacters Assigned To Each Numeric Key and press the MENU key on the keypadAdd PIN Change Other PINDelete PIN U002 DEBBIE SMITHDelete Token Add TokenToken Status Add KeyfobUser Name Delete KeyfobArea Assignment U001 JOHN SMITHAccess Assignment Timer GroupArea Status A001 Main OfficeTurn Area On/Off Area 1 NameTurn All Areas On Fri,Aug,13 5 34 pmArea Name Chime On/OffZone Status A001 Reception Area Z001 Zone 1 Name  Bypass ZonesSet Chime Zones Set Part 2 Zones Smoke Sensor ResetZone Name Z001 Zone 1 Name Output Status Walk Test All ZonesWalk Test A Single Zone Output Name Turn Output On/OffInternal Siren Test External Siren TestStrobe Test A002 Area 2 NameCall Forward On/Off Call/Answer RASCheck Web Email Email System LogCustomer Call Forward On NumberCall Forward Off Number Keypad 001 Volume L H Press OK to SAVE VolumeSend Test Report Press OK or MENUPanel Status Keypad 001 Backlight L H Press OK to SAVESystem Trouble BacklightDescription Trouble ConditionSolution 64 User Guide Table 5 Control PanleTrouble MessagesSet Date & Time History LogName TimeKeypad Hi/Lo Temp Start / Stop DayName Sk001 Schedule 1 NameWalk Test All Zones Battery TestVoltage = EMAIL SERVICE PHONE FAX EMAIL MONITORED BY Installation Details INSTALLED BY DATE PHONE FAXPHONE FAX EMAIL WARRANTY EXPIRES NOTES Solution 64 User GuideI ndex Page Bosch Security Systems 25 Huntingwood Drive 920304 Issue FTR1.2Huntingwood, NSW Australia Phone +612 Facsimile +612