Bosch Appliances BLCC110U manual Walk Test All Zones, Walk Test A Single Zone, Output Status

Page 18
Walk Test All Zones

Solution 64 Walk Test A Single Zone User Guide

Inputs > Input Testing >

Walk Test All Zones

MENU 3-9-0

This menu allows you to test all zones within an area at the same time. To successfully walk test each zone, you must open and close each zone.

Enter programming mode (PIN + MENU) then,

1.Press [MENU] + [3] + [9] + [0].

The keypad will display a list of areas that are available to walk test zones.

2.Use the [] and [] keys to select the area that you want to do walk test, then press [OK] to select. Alternatively, you can enter the area number, then press [OK].

The keypad will scroll all zones that you can test.

To test Z001 open then close Zone 1 Name

Press OK or MENU

To test Z002 open then close Zone 2 Name

Press OK or MENU

3.Open and close each zone that needs to be tested. A zone that has been successfully tested will no longer scroll on the keypad display.

When all zones have been tested, the keypad will display:

Selected zones have been

Tested OK

Press OK or MENU

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

Inputs > Input Testing >

Walk Test A Single Zone

MENU 3-9-1

This menu allows you to select a single zone to be tested via walk test.

Enter programming mode (PIN + MENU) then,

1.Press [MENU] + [3] + [9] + [1].

The keypad will display a list of zones that are available to be tested via walk test.

2.Use the [] and [] keys to select the zone that you want to walk test, then press [OK] to select. Alternatively, you can enter the zone number, then press [OK].

The keypad will display the zone to be tested.

To test Z001 open then close Zone 1 Name

Press OK or MENU

3.Open and close the zone that needs to be tested.

When the zone has been successfully faulted and restored, the keypad will display:

Z001 Zone 1 Name

Test Successful

Press OK or MENU

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

Outputs

The Solution 64 control panel has up to a maximum of 8 outputs. 4 outputs are available as standard with an additional 4 available when the optional output expander is fitted. Your installer will advise you on the exact makeup and configuration of you system.

Outputs > Commands >

Output Status

MENU 4-0-0

This menu allows you to view the status of each output. Enter programming mode (PIN + MENU) then,

1.Ensure that the system is turned off.

2.Press [MENU] + [4] + [0] + [0].

The keypad will display a list of outputs that the status may be viewed.

3.Using the [] and [] keys, highlight the output that you want to view the status information, then press [OK] to select. Alternatively, you can enter the output number and then press [OK].

The keypad will display the following when the output is off and OK:

18

Bosch Security Systems

09/06

BLCC110U

Image 18
Contents Solution Security SystemNotice of Liability Copyright NoticeTrademarks Telepermit NoteContents Program Menu Tree User’s Guide FeaturesI ntroduc tion Area 3 - Administration Area 4 - Dispatchfor 2 sec Reporting AlarmsAbout the Keypad for 2 secIcon MeaningMeaning Basic System Operation Characters Assigned To Each Numeric Key System ProgrammingChange Own PIN and press the MENU key on the keypadDelete PIN Change Other PINAdd PIN U002 DEBBIE SMITHToken Status Add TokenDelete Token Add KeyfobArea Assignment Delete KeyfobUser Name U001 JOHN SMITHArea Status Timer GroupAccess Assignment A001 Main OfficeTurn All Areas On Area 1 NameTurn Area On/Off Fri,Aug,13 5 34 pmZone Status Chime On/OffArea Name A001 Reception Area Bypass Zones Set Chime ZonesZ001 Zone 1 Name  Zone Name Smoke Sensor ResetSet Part 2 Zones Z001 Zone 1 Name Walk Test All Zones Walk Test A Single ZoneOutput Status Turn Output On/Off Output NameStrobe Test External Siren TestInternal Siren Test A002 Area 2 NameCheck Web Email Call/Answer RASCall Forward On/Off Email System LogCall Forward On Number Call Forward Off NumberCustomer Send Test Report VolumeKeypad 001 Volume L H Press OK to SAVE Press OK or MENUSystem Trouble Keypad 001 Backlight L H Press OK to SAVEPanel Status BacklightSolution 64 User Guide Trouble ConditionDescription Table 5 Control PanleTrouble MessagesName History LogSet Date & Time TimeName Start / Stop DayKeypad Hi/Lo Temp Sk001 Schedule 1 NameBattery Test Voltage =Walk Test All Zones PHONE FAX EMAIL WARRANTY EXPIRES NOTES Installation Details INSTALLED BY DATE PHONE FAXEMAIL SERVICE PHONE FAX EMAIL MONITORED BY Solution 64 User GuideI ndex Page Huntingwood, NSW Australia Phone +612 920304 Issue FTR1.2Bosch Security Systems 25 Huntingwood Drive Facsimile +612