Bosch Appliances BLCC110U Keypad 001 Backlight L H Press OK to SAVE, Panel Status, System Trouble

Page 24
Backlight

Solution 64

User Guide

Devices > Keypads >

Backlight

MENU 6-1-2

This menu allows you to adjust the brightness of the keypad’s LCD display backlight. Each keypad can have their display adjusted separately.

Enter programming mode (PIN + MENU) then,

1.Press [MENU] + [6] + [1] + [2].

The keypad will display the backlight screen.

Keypad 001 Backlight

L Keypad 001 BacklightPanel StatusSystem TroubleZ001 Zone 1 NameP001 System TroubleManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background H

Press Manual backgroundManual backgroundManual backgroundManual background OK to SAVE

2.Use the [] and [] keys to adjust the bar until the desired backlight is reached.

3.Press [OK] to save and exit, or press [MENU] to exit without saving.

System Events

Options in this section relate to programming of system wide options and interpretation of system trouble events when and if they occur. Some events such as open zones will appear and single events while other may be grouped together. In this case you need to drill down to see the specific detail for each event. Your installer will advise you how to interrogate system trouble events.

System > Commands >

Panel Status

MENU 7-0-0

The panel staus menu displays the panel software version information as well as highlighting any system troubles that are currently in effect. This is a view only location.

System > Commands >

System Trouble

MENU 7-0-1

To determine the non system (zone) trouble condition, highlight the zone number Z001 to Z064) that you want to view using the [] and [] keys, then press [OK] to select.

P001 System Trouble

Z001 Zone 1 Name

Z002 Zone 2 Name

Press  OK or MENU

2.If viewing system trouble conditions, the keypad will display similar to the following:

Panel 001 P001

Voltage= 13.9V Temp=36

Date And Time

Press OK or MENU

The third line of the keypad display scrolls between all current system trouble events.

If viewing non-system trouble conditions, the keypad will display similar to the following:

Zone 1 Name Z001

EOL = Open

Press OK or MENU

3.Press [OK] or [MENU] to exit the system trouble menu command:

If there are no system troubles, the keypad will display:

There are no

System troubles.

Press  OK or MENU

The System Trouble Menu displays all current system troubles in a list format. Some trouble events require you to drill down and non-system trouble that are curent within the Solution 64 control panel.

Enter programming mode (PIN + MENU) then,

1.Press [MENU] + [7] + [0] + [1].

The keypad will display a list of all current system and non system trouble conditions.

To determine the system trouble condition, highlight the

panel number (P001 to P002) that you want to view using the [] and [] keys, then press [OK] to select.

P001 System Trouble

Z001 Zone 1 Name

Z002 Zone 2 Name

Press  OK or MENU

Refer to the Trouble Messages table for a complete list of trouble events and their meanings.

24

Bosch Security Systems

09/06

BLCC110U

Image 24
Contents Solution Security SystemCopyright Notice TrademarksNotice of Liability Telepermit NoteContents Program Menu Tree Features I ntroduc tionUser’s Guide Area 3 - Administration Area 4 - DispatchReporting Alarms About the Keypadfor 2 sec for 2 secIcon MeaningMeaning Basic System Operation System Programming Change Own PINCharacters Assigned To Each Numeric Key and press the MENU key on the keypadChange Other PIN Add PINDelete PIN U002 DEBBIE SMITHAdd Token Delete TokenToken Status Add KeyfobDelete Keyfob User NameArea Assignment U001 JOHN SMITHTimer Group Access AssignmentArea Status A001 Main OfficeArea 1 Name Turn Area On/OffTurn All Areas On Fri,Aug,13 5 34 pmChime On/Off Area NameZone Status A001 Reception Area Bypass Zones Set Chime ZonesZ001 Zone 1 Name  Smoke Sensor Reset Set Part 2 ZonesZone Name Z001 Zone 1 Name Walk Test All Zones Walk Test A Single ZoneOutput Status Turn Output On/Off Output NameExternal Siren Test Internal Siren TestStrobe Test A002 Area 2 NameCall/Answer RAS Call Forward On/OffCheck Web Email Email System LogCall Forward On Number Call Forward Off NumberCustomer Volume Keypad 001 Volume L H Press OK to SAVESend Test Report Press OK or MENUKeypad 001 Backlight L H Press OK to SAVE Panel StatusSystem Trouble BacklightTrouble Condition DescriptionSolution 64 User Guide Table 5 Control PanleTrouble MessagesHistory Log Set Date & TimeName TimeStart / Stop Day Keypad Hi/Lo TempName Sk001 Schedule 1 NameBattery Test Voltage =Walk Test All Zones Installation Details INSTALLED BY DATE PHONE FAX EMAIL SERVICE PHONE FAX EMAIL MONITORED BYPHONE FAX EMAIL WARRANTY EXPIRES NOTES Solution 64 User GuideI ndex Page 920304 Issue FTR1.2 Bosch Security Systems 25 Huntingwood DriveHuntingwood, NSW Australia Phone +612 Facsimile +612