Bypass Zones

Solution 64 Set Chime Zones User Guide

Inputs > Commands >

Bypass Zones

MENU 3-0-2

This menu allows you to bypass or un-bypass a single or multiple zones before you turn the area All On, Part On or Part 2 On. When bypassing zones, it disables the ability for a zone to detect intrusion and sound an alarm.

A burglary zone will automatically become un-bypassed when you turn the corresponding area off (disarm). Any 24-Hr fire or 24-Hr non fire zones will need to be manually un-bypassed.

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [3] + [0] + [2].

A list of zones that can be bypassed will display on the keypad. A ‘√’ displayed on the right side of the zone name indicates that the zone is already bypassed.

Z001 Zone 1 Name

Z002 Zone 2 Name

Z003 Zone 3 Name

Press  OK or MENU

Inputs > Commands >

Set Chime Zones

MENU 3-0-3

This menu allows you to program zones to be monitored when the system is turned off. Chime mode is ideal to monitor a front door to sound the keypad buzzer when opened (faulted).

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [3] + [0] + [3].

A list of areas will display on the keypad.

2.Use the [] and [] keys to select the area that you want to program zones for chime mode, then press [OK]. Alternatively, you can enter the area number that you want to program chime zones, then press [OK].

The keypad will list all zones that can be programmed for chime mode. A ‘’ displayed on the right side of the zone name indicates that the zone is already set for chime.

Z001 Zone 1 Name

Z002 Zone 2 Name

Z003 Zone 3 Name

Press  OK or MENU

2.Use the [] and [] keys to select the zone that you want to bypass, then press [OK]. Alternatively, you can enter the zone number that you want to bypass, then press [OK].

If the zone is bypassed, the keypad will prompt:

Zone 1 Name Z001 is bypassed. To un-bypass, press OFF.

Press OK or MENU

If the zone is not bypassed, the keypad will prompt:

Zone 1 Name Z001 is un-bypassed. To bypass, press ON.

Press OK or MENU

3.Press [ON] or [OFF] to toggle the zone to be bypassed/un- bypassed.

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

Repeat steps 1 to 4 to bypass or un-bypass additional zones.

3.Use the [] and [] keys to select the zone that you want to set for chime, then press [OK]. Alternatively, you can enter the zone number that you want to set for chime, then press [OK].

If the zone is not programmed for chime, the keypad will prompt:

Zone 1 Name Z001

Zone Chime is OFF,

To turn ON, Press ON.

To Go Back Press OK

If the zone is programmed for chime, the keypad will prompt:

Zone 1 Name Z001

Zone Chime is ON.

To turn OFF, Press OFF.

To Go Back Press OK

4.Press [ON] or [OFF] to toggle the zone to be monitored when chime mode is turned on.

5.Press [OK] to save and exit, or press [MENU] to exit without saving.

16

Bosch Security Systems

09/06

BLCC110U

Image 16
Contents Solution Security SystemCopyright Notice TrademarksNotice of Liability Telepermit NoteContents Program Menu Tree Features I ntroduc tionUser’s Guide Area 3 - Administration Area 4 - DispatchReporting Alarms About the Keypadfor 2 sec for 2 secMeaning IconMeaning Basic System Operation System Programming Change Own PINCharacters Assigned To Each Numeric Key and press the MENU key on the keypadChange Other PIN Add PINDelete PIN U002 DEBBIE SMITHAdd Token Delete TokenToken Status Add KeyfobDelete Keyfob User NameArea Assignment U001 JOHN SMITHTimer Group Access AssignmentArea Status A001 Main OfficeArea 1 Name Turn Area On/OffTurn All Areas On Fri,Aug,13 5 34 pmChime On/Off Area NameZone Status A001 Reception Area Set Chime Zones Bypass ZonesZ001 Zone 1 Name  Smoke Sensor Reset Set Part 2 ZonesZone Name Z001 Zone 1 Name Walk Test A Single Zone Walk Test All ZonesOutput Status Turn Output On/Off Output NameExternal Siren Test Internal Siren TestStrobe Test A002 Area 2 NameCall/Answer RAS Call Forward On/OffCheck Web Email Email System LogCall Forward Off Number Call Forward On NumberCustomer Volume Keypad 001 Volume L H Press OK to SAVESend Test Report Press OK or MENUKeypad 001 Backlight L H Press OK to SAVE Panel StatusSystem Trouble BacklightTrouble Condition DescriptionSolution 64 User Guide Table 5 Control PanleTrouble MessagesHistory Log Set Date & TimeName TimeStart / Stop Day Keypad Hi/Lo TempName Sk001 Schedule 1 NameVoltage = Battery TestWalk Test All Zones Installation Details INSTALLED BY DATE PHONE FAX EMAIL SERVICE PHONE FAX EMAIL MONITORED BYPHONE FAX EMAIL WARRANTY EXPIRES NOTES Solution 64 User GuideI ndex Page 920304 Issue FTR1.2 Bosch Security Systems 25 Huntingwood DriveHuntingwood, NSW Australia Phone +612 Facsimile +612