Bosch Appliances BLCC110U manual Timer Group, Access Assignment, Area Status, A001 Main Office

Page 13
Timer Group

time group to specify the access period, day of the week and holidays. To now restrict the user, they must belong also to the same timer group. This now restricts the user from accessing the system outside the nominated times and days within the schedules linked to the timer group.

User

Can only belong to 1 timer group.

Schedules

Multiple schedules can be linked to the same timer group.

Time Groups

There are 8 different timer groups available.

Timer Group Example

1.To set up a timer group you need to select an unused timer group number from 1 to 8, in this example we will assume timer group number to be 5.

2.Select an unused schedule and program the times and day of the week then assign the schedule to timer group 5.

3.Then under user properties assign the users who you wish to restrict to timer group 5. Remember that you are only able to assign a user to one timer group.

A master code holder is able to change the schedules so they can change the access times for a given user. If a user tries to operate the system outside their assigned timer group periods then access will be denied.

Access > User Properties >

Timer Group

MENU 1-4-4

This menu is used to assign a User to a Timer Group. Timer Groups can be used to restrict User access to be within specific times defined by schedules. Each User can only be assigned to one Timer Group. Setting this option to 0 will give the User 24 hour access to the system.

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [1] + [4] + [4] and select the user from the list then press [OK].

Ur001 John Smith

Ur002 Debbie Smith

Ur003 User 3 Name

Press  OK or MENU

2.Using the numeric keys, enter the Timer Group. Valid entries are 1 – 8 or 0 to disable.

Timer Group Ur001

00

Press 0-9 OK to SAVE

3.Press [OK] to save and exit or press [MENU] to exit without saving.

 

Solution 64 User Guide

Access > User Properties >

 

 

Access Assignment

 

MENU 1-4-5

This menu allows you to assign each user to one or more access groups. An access group is used to allow and/or restrict which users have access to various system outputs. These outputs can be used to control door strikes, gates or roller doors etc.

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [1] + [4] + [5] and select the user from the list then press [OK].

Ur001 John Smith

Ur002 Debbie Smith

Ur003 User 3 Name

Press  OK or MENU

2.Use the up and down arrow keys to highlight the Access Group then press the [ON] key to select or the [OFF] key to deselect.

Access Group 1 Access Group 2 Access Group 3

Press  OK ON OFF MENU

3.Repeat Step 2 until all required Access Groups are programmed, then press [OK] to save and exit or press [MENU] to exit without saving.

Areas

The Solution 64 control panel has the ability to be partitioned up to 8 individual areas. This section outlines various commands that control individual areas.

Areas > Commands >

Area Status

MENU 2-0-0

This menu allows users the ability view the area status of the current area or the status of a different area. This menu is only available via a keypad who’s corresponding area is turned off.

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [2] + [0] + [0].

A list of available areas will display on the keypad.

A001 Main Office

A002 Production

A003 Warehouse

PRESS , OK or MENU

2.Use the [] and [] keys to select the area that you want to view the status information, then press [OK] to select. Alternatively, you can enter the area number, then press [OK].

The keypad will display the area status information.

Bosch Security Systems

 

09/06

 

BLCC110U

13

 

 

Image 13
Contents Security System SolutionTrademarks Copyright NoticeNotice of Liability Telepermit NoteContents Program Menu Tree I ntroduc tion FeaturesUser’s Guide Area 3 - Administration Area 4 - DispatchAbout the Keypad Reporting Alarmsfor 2 sec for 2 secMeaning IconMeaning Basic System Operation Change Own PIN System ProgrammingCharacters Assigned To Each Numeric Key and press the MENU key on the keypadAdd PIN Change Other PINDelete PIN U002 DEBBIE SMITHDelete Token Add TokenToken Status Add KeyfobUser Name Delete KeyfobArea Assignment U001 JOHN SMITHAccess Assignment Timer GroupArea Status A001 Main OfficeTurn Area On/Off Area 1 NameTurn All Areas On Fri,Aug,13 5 34 pmArea Name Chime On/OffZone Status A001 Reception Area Set Chime Zones Bypass ZonesZ001 Zone 1 Name  Set Part 2 Zones Smoke Sensor ResetZone Name Z001 Zone 1 Name Walk Test A Single Zone Walk Test All ZonesOutput Status Output Name Turn Output On/OffInternal Siren Test External Siren TestStrobe Test A002 Area 2 NameCall Forward On/Off Call/Answer RASCheck Web Email Email System LogCall Forward Off Number Call Forward On NumberCustomer Keypad 001 Volume L H Press OK to SAVE VolumeSend Test Report Press OK or MENUPanel Status Keypad 001 Backlight L H Press OK to SAVESystem Trouble BacklightDescription Trouble ConditionSolution 64 User Guide Table 5 Control PanleTrouble MessagesSet Date & Time History LogName TimeKeypad Hi/Lo Temp Start / Stop DayName Sk001 Schedule 1 NameVoltage = Battery TestWalk Test All Zones EMAIL SERVICE PHONE FAX EMAIL MONITORED BY Installation Details INSTALLED BY DATE PHONE FAXPHONE FAX EMAIL WARRANTY EXPIRES NOTES Solution 64 User GuideI ndex Page Bosch Security Systems 25 Huntingwood Drive 920304 Issue FTR1.2Huntingwood, NSW Australia Phone +612 Facsimile +612