Bosch Appliances BLCC110U manual Battery Test, Voltage =, Walk Test All Zones

Page 28
Battery Test

Solution 64 Voltage = 13.4V User Guide

System > System Testing >

Walk Test All Zones

MENU 7-9-0

This menu allows you to test all zones within an area at the same time.

Enter programming mode (PIN + MENU) then,

1.Press [MENU] + [7] + [9] + [0].

The keypad will display a list of areas that are available to walk test zones.

2.Use the [] and [] keys to select the area that you want to do walk test, then press [OK] to select. Alternatively, you can enter the area number, then press [OK].

The keypad will scroll all zones that you can test.

To test Z001 open then close Zone 1 Name

Press OK or MENU

To test Z002 open then close Zone 1 Name

Press OK or MENU

3.Open and close each zone that needs to be tested. A zone that has been successfully tested will no longer scroll on the keypad display.

When all zones have been tested, the keypad will display:

Selected zones have been

Tested OK

Press OK or MENU

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

System > System Testing >

Battery Test

MENU 7-9-1

This menu allows you to manually test the systems back up battery. The Solution 64 will automatically test the battery once per day and every time the system is armed.

The battery test can take up to two minutes to complete and the keypad will display the voltage of the battery during the test.

Enter programming mode (PIN + MENU) then,

1.Press [MENU] + [7] + [9] + [2].

The keypad will display the battery voltage whilst under test:

Battery test in progress.

Please wait..

Voltage = 13.4V

To Go Back Press OK

If the battery has passed the test, the keypad will display:

Battery test Passed.

Press OK to continue

If the battery has failed the test, the keypad will display:

Battery test Failed.

Please Call for Service.

Press OK to continue

2.Press [OK] to exit.

28

Bosch Security Systems

09/06

BLCC110U

Image 28
Contents Solution Security SystemCopyright Notice TrademarksNotice of Liability Telepermit NoteContents Program Menu Tree Features I ntroduc tionUser’s Guide Area 3 - Administration Area 4 - DispatchReporting Alarms About the Keypadfor 2 sec for 2 secMeaning IconMeaning Basic System Operation System Programming Change Own PINCharacters Assigned To Each Numeric Key and press the MENU key on the keypadChange Other PIN Add PINDelete PIN U002 DEBBIE SMITHAdd Token Delete TokenToken Status Add KeyfobDelete Keyfob User NameArea Assignment U001 JOHN SMITHTimer Group Access AssignmentArea Status A001 Main OfficeArea 1 Name Turn Area On/OffTurn All Areas On Fri,Aug,13 5 34 pmChime On/Off Area NameZone Status A001 Reception Area Set Chime Zones Bypass ZonesZ001 Zone 1 Name  Smoke Sensor Reset Set Part 2 ZonesZone Name Z001 Zone 1 Name Walk Test A Single Zone Walk Test All ZonesOutput Status Turn Output On/Off Output NameExternal Siren Test Internal Siren TestStrobe Test A002 Area 2 NameCall/Answer RAS Call Forward On/OffCheck Web Email Email System LogCall Forward Off Number Call Forward On NumberCustomer Volume Keypad 001 Volume L H Press OK to SAVESend Test Report Press OK or MENUKeypad 001 Backlight L H Press OK to SAVE Panel StatusSystem Trouble BacklightTrouble Condition DescriptionSolution 64 User Guide Table 5 Control PanleTrouble MessagesHistory Log Set Date & TimeName TimeStart / Stop Day Keypad Hi/Lo TempName Sk001 Schedule 1 NameVoltage = Battery TestWalk Test All Zones Installation Details INSTALLED BY DATE PHONE FAX EMAIL SERVICE PHONE FAX EMAIL MONITORED BYPHONE FAX EMAIL WARRANTY EXPIRES NOTES Solution 64 User GuideI ndex Page 920304 Issue FTR1.2 Bosch Security Systems 25 Huntingwood DriveHuntingwood, NSW Australia Phone +612 Facsimile +612