Bosch Appliances D9412GV2 manual Telephone Connections, Registration, Notification, Location

Page 27

D9412GV2/D7412GV2 Operation and Installation Guide 7.0 Telephone Connections

7.0Telephone Connections

7.1Registration

The Bosch Security Systems D9412GV2/D7412GV2 Control Panels are registered with the Federal Communication Commission (FCC) under Part 68, for connection to the public telephone system using an RJ31X or RJ38X jack installed by the local telephone company.

An RJ31X jack can be modified by placing a jumper wire between Terminals 2 and 7 to become an RJ38X jack.

7.2Notification

Do not connect registered equipment to party lines or coin-operated telephones. Notify the local telephone company and provide the following information before connecting the control panel to the telephone network:

The particular line to which the control panel will be connected

Make (Bosch Security Systems), model (D9412GV2 or D7412GV2), and serial number of the control panel

FCC registration number: AJ9MUL-46532-AL-E

Ringer equivalence for the control panel: 0.4B

7.3Location

To prevent jamming of signals, wire the RJ31X or RJ38X jack before the in-house telephone system to support line seizure (Figure 7). Install the jack on the street side of the telephone switch, wired ahead of any PBX equipment. Line seizure temporarily interrupts normal telephone usage while the control panel sends data. After installation, confirm that the control panel seizes the line, acquires dial tone, reports correctly to the receiver, and releases the telephone line to the in- house telephone system.

Figure 7:

 

RJ31X Wiring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RJ31X

 

 

1

 

 

 

 

 

 

 

 

 

 

 

RING (red)

TIP (green)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R1

 

R

T

T1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

 

 

 

 

7 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

1

 

4

5

8

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

5

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

6

1 -

RJ31X Jack

2 -

(TIP)

3 -

(RING)

4 - Telco connector block

5 - Outside telco

6 - Premises telephone

7.4Telephone Cord Connection

Connect one end of a D161 (2.1 m [7 ft.]) or a D162 [61 cm (2 ft.)] Telephone Cord to the telco cord connector located on the bottom left corner of the control panel. Refer to Figure 8. Connect the other end to the RJ31X or RJ38X jack.

To supervise the phone cord, use an RJ38X jack.

Figure 8: Phone Connector, Phone LED, and Operation Monitor LED Locations

 

 

PHONE

ON when

 

 

RED

communicating

1

LED

 

OFF when idle

 

PHONE LINE SEIZED

 

TIP

TELCO CORD

RING

 

 

MODEL D161

 

 

 

 

 

 

PHONE LINE

 

SEIZED

 

2

 

TIP

RING

 

TELCO

Point 8

 

D5200/D5360

S3 Option

 

PROG CONN

Closed = 1KEOL

Normal Operation

Open =AB-12 UL

Bell Box 220 K

11

12

13

14

15

16

17

18

19

20

21

22

GRN

3

1 -

Phone LED (red)

3 - Operation Monitor LED (green)

2 -

Telephone cord connector

 

 

 

 

 

 

 

 

 

 

 

 

Bosch Security Systems, Inc. 5/05 F01U003641B

27

Image 27
Contents D9412GV2/D7412GV2 Operation and Installation GuideFederal Communications Commission FCC Rules TrademarksCertifications and Approvals Listings and ApprovalsBosch Security Systems, Inc /05 F01U003641B Contents D9412GV2/D7412GV2 Operation and Installation Guide Tables FiguresRelated Documentation IntroductionPrecautions during Installation Lightning StrikesEffects Configuration and Parts OverviewGV2 Series Control Panel Differences Parts Available by Separate Order Parts ListAssembly Literature PackCompatible Accessories AccessoriesFeatures in the D9412GV2 and D7412GV2 Ground Fault Detection Added Feature KeyswitchAccess Control Ground Fault DetectionOther Features NetCom FunctionsProgramming Mounting Enclosure InstallationInstallation Preparation Enclosure OptionsTerminal Installing the Control PanelConnecting Earth Ground Terminals to earth ground Ground Fault Detect EnableGround Fault Impedance Enabling Ground Fault DetectionGround Fault Detection Status 4 D9412GV2 and D7412GV2 Ground Fault SpecificationsCompleting the Installation Installing the Point Chart Label Testing the SystemProgramming the Control Panel Power Supply Primary Power Terminals 1Secondary Power Terminals Installing the Battery Replacing the Battery Non-Power-Limited WiringBattery Supervision Battery Charging Circuit Float ChargeBattery Discharge and Recharge Schedule Charging Status and Low Battery LEDs Programmable Power Output Terminals 6, 7, Power OutputsTotal Available Power Continuous Power Output Terminals 24,Terminals 6 Available PowerFire System Power Formula Verification/Reset RelayLocation Telephone ConnectionsRegistration NotificationTelephone Line Monitor Phone LED RedOperation Monitor LED Green Dialing Format11 D928 Dual Phone Line Switcher DescriptionOperation Telephone Connections Installing the D928 MountingWiring AC Power LEDPoint Parameters On-Board PointsTerminals 11 to 22 Description Point Sensor LoopsPoint Response Time 3 4 5 Point Zonex Bus D9412GV2 Terminals and D7412GV2 Terminals Off-Board PointsListings Off-Board Point ErrorsD8125, D8127 and D9127 Popit Modules 5 D9412GV2/D7412GV2 Responses to Missing Point ConditionsConnecting the D8125 Popex to the D9412GV2 Control Panel Connecting the D8125 Popex to the D7412GV2 Panel Data Expansion Loop Wire Specifications Installing the D8125 Popex ModuleWiring the D8125 to the Control Panel Wiring POPITs to the Data Expansion LoopWiring Data Expansion Loops to Popex Modules Popit Sensor LoopsPopit Module Point Assignments D8128D OctoPOPIT Module Installation Setting the OctoPOPIT SwitchesAddress Switches Mounting OctoPOPITs D8128D OctoPOPIT Switch Settings for D9412GV2 and D7412GV2Point DIP Switches Wiring OctoPOPITsTerminal Strip Connections Using the Terminal StripConnecting D8128D OctoPOPITs to the D9412GV2 First address on Zonex Bus Sensor loops OctoPOPIT Sensor Loops Using Molex ConnectorsD8128D OctoPOPIT Sensor Loops Testing Off-Board Points10.1 D8129 OctoRelay Off-Board RelaysSetting the OctoRelay switches or Configuring the D8129 OctoRelayD8129 OctoRelay Switch Settings Relay outputs can activate when you areNumber of D8128Ds Used with D8129s Wiring ConnectionsOutputs when you perform this function 10.2 D811 Arm Status Relay ModuleD811 for Relay On-board points D811 for Relay Arming Devices DescriptionKeypad Terminals 29 to Extra Power for More Keypads Wire Limits for Individual KeypadsMaintained Contact KeyswitchSilencing the Bell Momentary Contact12.4 D9210B Wiegand Control Interface Module InstallationSDI Devices 12.3 D9131A Parallel Printer Interface ModuleSDI Address AccessAddress Switch Settings for Access Control Module Address SettingsNetwork Interface Modules Connecting the D9133DC12.6.1 D9133DC Direct Connect Programming Module Used as an External ModemDX4020 DIP Switch Settings Accessory Connector Programmer and Accessory ConnectionsProgrammer Connector Programmer Access Reports14.1 D9412GV2 Faceplate FaceplatesD7412GV2 14.2 D7412GV2 FaceplateD9412GV2 Control Panel Appendix a System Wiring Diagrams, Issue aD9412GV2 Popex D7412GV2 Control Panel D7412GV2, Power Supply SideUL Smoke Detector Compatibility P/N 33284 for D7412GV2, Input Points and Peripheral DevicesD7412GV2, SDI Devices Zonex 1 Point Address Chart Appendix B Point Address ChartsZonex 2, Points 129 to 247 D9412GV2 Only Zonex 2 Point Address ChartD9412GV2/D7412GV2 Program Entry Guide P/N F01U003636 SpecificationsBosch Security Systems, Inc /05 F01U003641B Bosch Security Systems F01U003641B
Related manuals
Manual 158 pages 17.38 Kb

D9412GV2 specifications

The Bosch D9412GV2 is an exceptional dishwasher that stands out in the competitive world of home appliances. Known for its reliability and advanced features, this model offers a blend of cutting-edge technology and user-friendly design that appeals to modern households.

One of the most noteworthy features of the D9412GV2 is its impressive cleaning performance. Boasting a unique combination of powerful jets and specialized wash cycles, it ensures that even the toughest stains are removed effectively. The dishwasher features Bosch’s patented PrecisionWash system, which utilizes intelligent sensors to monitor the wash cycle’s progress and adjust the water spray for optimal cleaning results. This not only guarantees sparkling dishes but also conserves water and energy.

In terms of capacity, the D9412GV2 does not disappoint. It has a spacious interior that is designed to accommodate up to 16 place settings, making it an ideal choice for families or those who frequently entertain guests. The adjustable racks and flexible loading options allow users to maximize space and customize the dishwasher to suit their unique needs. The third rack is particularly useful for utensils and smaller items, providing additional space that enhances efficiency.

The dishwasher is also engineered with noise reduction features for a quieter operation. With a sound rating of 44 decibels, it operates silently in the background, allowing for uninterrupted conversations and a peaceful home environment. This is especially beneficial for open-concept living spaces.

Energy efficiency is another hallmark of the Bosch D9412GV2. It is Energy Star certified, reflecting its commitment to sustainable practices. It uses less water and electricity without compromising performance, making it a responsible choice for eco-conscious consumers.

Moreover, the presence of the Home Connect feature allows users to control and monitor their dishwasher remotely via a smartphone app. This innovative technology enables users to start or stop cycles, receive notifications, and even download new wash programs, adding convenience and flexibility to busy lifestyles.

In conclusion, the Bosch D9412GV2 is a state-of-the-art dishwasher that excels in cleaning performance, capacity, and energy efficiency. With its innovative technologies and thoughtful design, it represents Bosch's commitment to quality and customer satisfaction, making it a valuable addition to any kitchen.