D9412GV2/D7412GV2 Operation and Installation Guide 12.0 SDI Devices

12.4.1 Access

Using Wiegand style cards or tokens, the D9210B can allow access for up to 996 cards or tokens on the D9412GV2, and up to 396 on the D7412GV2. User access authority can be configured to restrict access to certain doors or to certain periods of time. The reading of access cards, in addition to granting access, can control whether the system disarms. Used with the D9412GV2, the D9210B recognizes 249 master users by user name, passcode, and access authority. The D9210B recognizes 99 master users when used with the D7412GV2. Each master user supports three sub-users with unique cards or tokens having the same access level as the master user.

12.4.2 Switch Settings

Switches on the D9210B assign a unique address (1 to

8)to each module. Table 24 shows the correct switch setting for each D9210B address.

Table 24: Address Switch Settings for Access Control Module

 

 

 

 

 

 

 

 

Door Module

 

DIP Switch Settings

 

Addresses

1

2

3

41

52

 

62

1

ON

ON

ON

 

ON

 

ON

2

OFF

ON

ON

 

ON

 

ON

---------------D7412GV2 Maximum---------------

 

3

ON

OFF

ON

 

ON

 

ON

4

OFF

OFF

ON

 

ON

 

ON

5

ON

ON

OFF

 

ON

 

ON

6

OFF

ON

OFF

 

ON

 

ON

7

ON

OFF

OFF

 

ON

 

ON

8

OFF

OFF

OFF

 

ON

 

ON

1Switch 4, Fail Safe Mode:

ON = If SDI bus fails, relay energizes.

OFF = If SDI bus fails, relay de-energizes.

2Switches 5 and 6 must remain in the ON position.

12.5SDI Address 80

SDI Address 80, available on the D9412GV2 and D7412GV2 Control Panels, allows for two-way SDI to RS-232 information. This address is used with home or building automation software. A D9133 Serial Interface Module is required for this application.

12.5.1 Serial Interface Modules (SIMs)

The DX4010i RS-232 Serial Interface Module and the D9133 Serial Interface Module are four-wire powered SDI devices that provide connection for RS-232 devices to the D9412GV2 and D7412GV2 Control Panels. They use a specific communication protocol that is provided upon request. Contact Bosch Security Systems Technical Support Monday through Friday from 5 AM to 5 PM EST at 888-886-6189.

The DX4010i can be installed up to 305 m (1000 ft.) from the control panel, using 0.8 mm (22 AWG) wire. The DX4010i was not investigated by UL. Do not use DX4010i in UL Listed installations.

The D9133 can be installed up to 305 m (1000 ft.) from the control panel using 1.2 mm (18 AWG) wire. The D9133 was not investigated by UL. Do not use D9133 in UL Listed installations.

12.5.2 Address Settings

No jumper settings are required for the D9133 (SDI Address 80) for home or building automation purposes (Figure 26). Remove the jumper shunts for this purpose.

Figure 26: D9133 Jumper Setting for Address 80

1 2 3 4

80

The DX4010i has specific DIP switch settings for SDI Address 80 when home or building automation is desired. Figure 27 on page 59 shows the correct settings for Address 80.

58

Bosch Security Systems, Inc. 5/05 F01U003641B

Image 58
Contents Operation and Installation Guide D9412GV2/D7412GV2Listings and Approvals TrademarksCertifications and Approvals Federal Communications Commission FCC RulesBosch Security Systems, Inc /05 F01U003641B Contents D9412GV2/D7412GV2 Operation and Installation Guide Figures TablesIntroduction Related DocumentationLightning Strikes Precautions during InstallationEffects Overview Configuration and PartsGV2 Series Control Panel Differences Literature Pack Parts ListAssembly Parts Available by Separate OrderAccessories Compatible AccessoriesFeatures in the D9412GV2 and D7412GV2 Ground Fault Detection KeyswitchAccess Control Ground Fault Detection Added FeatureNetCom Functions Other FeaturesProgramming Enclosure Options InstallationInstallation Preparation Mounting EnclosureTerminals to earth ground Ground Fault Detect Enable Installing the Control PanelConnecting Earth Ground Terminal4 D9412GV2 and D7412GV2 Ground Fault Specifications Enabling Ground Fault DetectionGround Fault Detection Status Ground Fault ImpedanceCompleting the Installation Testing the System Installing the Point Chart LabelProgramming the Control Panel Primary Power Terminals 1 Power SupplySecondary Power Terminals Installing the Battery Non-Power-Limited Wiring Replacing the BatteryBattery Charging Circuit Float Charge Battery SupervisionBattery Discharge and Recharge Schedule Charging Status and Low Battery LEDs Continuous Power Output Terminals 24, Power OutputsTotal Available Power Programmable Power Output Terminals 6, 7,Verification/Reset Relay Available PowerFire System Power Formula Terminals 6Notification Telephone ConnectionsRegistration LocationDialing Format Phone LED RedOperation Monitor LED Green Telephone Line MonitorDescription 11 D928 Dual Phone Line SwitcherOperation AC Power LED Installing the D928 MountingWiring Telephone ConnectionsPoint Sensor Loops On-Board PointsTerminals 11 to 22 Description Point ParametersPoint Response Time 3 4 5 Off-Board Points Point Zonex Bus D9412GV2 Terminals and D7412GV2 Terminals5 D9412GV2/D7412GV2 Responses to Missing Point Conditions Off-Board Point ErrorsD8125, D8127 and D9127 Popit Modules ListingsConnecting the D8125 Popex to the D9412GV2 Control Panel Connecting the D8125 Popex to the D7412GV2 Panel Wiring POPITs to the Data Expansion Loop Installing the D8125 Popex ModuleWiring the D8125 to the Control Panel Data Expansion Loop Wire SpecificationsPopit Sensor Loops Wiring Data Expansion Loops to Popex ModulesPopit Module Point Assignments D8128D OctoPOPIT Module Setting the OctoPOPIT Switches InstallationAddress Switches Wiring OctoPOPITs D8128D OctoPOPIT Switch Settings for D9412GV2 and D7412GV2Point DIP Switches Mounting OctoPOPITsUsing the Terminal Strip Terminal Strip ConnectionsConnecting D8128D OctoPOPITs to the D9412GV2 First address on Zonex Bus Sensor loops Using Molex Connectors OctoPOPIT Sensor LoopsTesting Off-Board Points D8128D OctoPOPIT Sensor LoopsOff-Board Relays 10.1 D8129 OctoRelayRelay outputs can activate when you are Configuring the D8129 OctoRelayD8129 OctoRelay Switch Settings Setting the OctoRelay switches or10.2 D811 Arm Status Relay Module Wiring ConnectionsOutputs when you perform this function Number of D8128Ds Used with D8129sD811 for Relay On-board points D811 for Relay Description Arming DevicesKeypad Terminals 29 to Wire Limits for Individual Keypads Extra Power for More KeypadsKeyswitch Maintained ContactMomentary Contact Silencing the Bell12.3 D9131A Parallel Printer Interface Module InstallationSDI Devices 12.4 D9210B Wiegand Control Interface ModuleAddress Settings AccessAddress Switch Settings for Access Control Module SDI AddressUsed as an External Modem Connecting the D9133DC12.6.1 D9133DC Direct Connect Programming Module Network Interface ModulesDX4020 DIP Switch Settings Programmer Access Reports Programmer and Accessory ConnectionsProgrammer Connector Accessory ConnectorFaceplates 14.1 D9412GV2 Faceplate14.2 D7412GV2 Faceplate D7412GV2Appendix a System Wiring Diagrams, Issue a D9412GV2 Control PanelD9412GV2 Popex D7412GV2, Power Supply Side D7412GV2 Control PanelD7412GV2, Input Points and Peripheral Devices UL Smoke Detector Compatibility P/N 33284 forD7412GV2, SDI Devices Appendix B Point Address Charts Zonex 1 Point Address ChartZonex 2 Point Address Chart Zonex 2, Points 129 to 247 D9412GV2 OnlySpecifications D9412GV2/D7412GV2 Program Entry Guide P/N F01U003636Bosch Security Systems, Inc /05 F01U003641B Bosch Security Systems F01U003641B
Related manuals
Manual 158 pages 17.38 Kb

D9412GV2 specifications

The Bosch D9412GV2 is an exceptional dishwasher that stands out in the competitive world of home appliances. Known for its reliability and advanced features, this model offers a blend of cutting-edge technology and user-friendly design that appeals to modern households.

One of the most noteworthy features of the D9412GV2 is its impressive cleaning performance. Boasting a unique combination of powerful jets and specialized wash cycles, it ensures that even the toughest stains are removed effectively. The dishwasher features Bosch’s patented PrecisionWash system, which utilizes intelligent sensors to monitor the wash cycle’s progress and adjust the water spray for optimal cleaning results. This not only guarantees sparkling dishes but also conserves water and energy.

In terms of capacity, the D9412GV2 does not disappoint. It has a spacious interior that is designed to accommodate up to 16 place settings, making it an ideal choice for families or those who frequently entertain guests. The adjustable racks and flexible loading options allow users to maximize space and customize the dishwasher to suit their unique needs. The third rack is particularly useful for utensils and smaller items, providing additional space that enhances efficiency.

The dishwasher is also engineered with noise reduction features for a quieter operation. With a sound rating of 44 decibels, it operates silently in the background, allowing for uninterrupted conversations and a peaceful home environment. This is especially beneficial for open-concept living spaces.

Energy efficiency is another hallmark of the Bosch D9412GV2. It is Energy Star certified, reflecting its commitment to sustainable practices. It uses less water and electricity without compromising performance, making it a responsible choice for eco-conscious consumers.

Moreover, the presence of the Home Connect feature allows users to control and monitor their dishwasher remotely via a smartphone app. This innovative technology enables users to start or stop cycles, receive notifications, and even download new wash programs, adding convenience and flexibility to busy lifestyles.

In conclusion, the Bosch D9412GV2 is a state-of-the-art dishwasher that excels in cleaning performance, capacity, and energy efficiency. With its innovative technologies and thoughtful design, it represents Bosch's commitment to quality and customer satisfaction, making it a valuable addition to any kitchen.