Kenmore 153.335942, 153.335845, 153.335962 Venting, USE Without Power Cord contd, Wiring Diagram

Page 15

Installation Instructions (cont'd)

USE WITHOUT POWER CORD (cont'd)

3.A standard ½" conduit opening has been made in the water beater junction box for the conduit connection.

4.Use wire nuts and connect the power supply wiring to the wires inside the water heater's junction box.

5.The water heater must be electrically "grounded" by the installer. A green ground screw has been provided on the

water heater's junction box. Connect ground wire to this location. For complete grounding details and all allowable exceptions, refer to local codes or in the absence of local codes, with the latest edition of the National Electrical Code, ANSI/NFPA 70.

6. Replace the wiring junction cover using the screw provided.

WIRING DIAGRAM

A_RP_ESSUnE _WlrCH

o_o_

SWITCH

 

OAS

 

 

!l

 

P_E_RE

 

_JTE

 

 

_EUTR_

 

 

SW_rCH

 

 

 

 

 

HOT

 

 

 

 

 

 

 

 

ir

P_ oAs

 

......

11

w......,,0

 

ESSUnE

I_OVGAS

 

S_TCH

 

 

SOLEN_O HI_M T

NO

 

 

__

/

 

NC

 

 

INOI_TOR UGHT I_OV

REswlTCH

t

 

O

 

 

t20V _AS

 

 

 

 

 

SOLENOIO

 

 

Venting

_,WARNING

To insureproperventingof thisgas.firedwater heater,the cor- rect vent pipe diameter must be utilized. Any additionsof other gas appliances on vent with this water heater will adverselyaffectthe operationofthe water heater,

The combustion and ventilation air flow must not be obstructed.

_,WARNING

The water heater with draft hood installedmust be properlyI vented to a chimneywhichterminatesoutdoors.Never oper- ate the water heaterunlessit isventedto the outdoorsandhas adequateair supplyto avoidrisksof improperoperation,explo-

_,WARNING3" diameter

The vent pipe from the water heater must be I/4 inch per/

PVC schedule40 pipe and must slopeupward

J

linear foot.

All vent gases must be completely vented to the outdoors of the structure (dwelling).

sionor asphyxiation.

_,WARNING

Obstructedor deterioratedvent systemsmay presenta serious

healthrisk or asphyxation.

Failureto haverequired clearancesbetweenwater heater and

•,WARNINGI

combustiblematerialwill result in a fire hazard.

I

15

Image 15
Contents Model No For Your SafetyAN Odorant is Added to the GAS Used by this Water Heater What to do if YOU Smell GASSafety Precautions Awarning AwarningAGE Must be prop Safety PrecautionsContents Customer Responsibilities Product SpecificationsBasic Tools When Sweat SolderingMaterials and Basic Tools Needed Materials NeededRemoving the Old Water Heater Installation InstructionsInstallation Instructions Locating the New Water HeaterOr Property Damage Property Damage Installation Instructions contdVenting Clearances Combustiblematerialwill resultin a fire hazardENT to Water Piping Installation Completed Using Sears Installation KITTemperature-Pressure Relief Valve Installation Instructions contdFilling the Water Heater WiringUSE with Power Cord USE Without Power CordVent pipe from the water heater must be I/4 inch per USE Without Power Cord contdWiring Diagram VentingPVC Schedule 40 Vent Piping Venting System Example Installations For ALL ModelsVenting contd HillPrecautions Venting System Example Installations for ALL Models contdConnecting PVC, ABS or Cpvc Pipe Vent to Blower Installation Showing USE of PVC, ABS or Cpvc PipeScEw Sediment Trap GAS Piping with Flexible ConnectorGas Piping He appliance and its gas connection must be leak testedModel Rating Plate Installation ChecklistTemperature Before Lighting the PilotBefore the Water Heater will Operate Operating InstructionsBefore Lighting Propane L,P. GAS Water LightingOperating Instructions contd Whatto Doif YousmellgasTHERMOCOUPLEP,LOTBURNER Temperature Regulation Service and Adjustment Draining Service and Adjustment contdGas Control Valve & Burner Assembly Replacement Information Temperature-Pressure ReliefWasher Drain Valve Washer ReplacementService HousekeepingTroubleshooting Guide Start Up ConditionsThermal Expansion Smelly Water Troubleshooting Guide contdCondensation SMOKE/ODORNot Enough or no HOT Water High Temperature Shut OFF SystemOperational Conditions contd AIR in HOT Water FaucetsLeakage Checkpoints Troubleshooting Guide contdIwarningi Thermostat and GAS Supply CheckSwc...,c Diagram for Electrical System Check on pages 34Electrical System Check Use diagram on Thec#togrouod/r110,I-.- Isindicator,20 o,tshtooI Model Numbers Parts Order List153.335816 40 Gal Parts Order List contdParts Order List Power Miser TM 9 Power Vent GAS Water HeatersParts Order List contd Power Miser TM 9 Power Vent GAS Water Heaters Model NumbersAbout Your Warranty Warranty
Related manuals
Manual 40 pages 985 b

153.335862, 153.335942, 153.335916, 153.335962, 153.335845 specifications

The Kenmore 153 series, comprising models 153.335916, 153.335942, 153.335962, 153.335845, and 153.335862, is renowned for its innovative design and exceptional performance in household appliances. These models are predominantly known for their washing machines and dryers, which have become staples in modern homes.

One of the standout features of the Kenmore 153 series is its advanced wash technology. Each model incorporates a high-efficiency system designed to reduce water consumption while maximizing cleaning power. The patented triple-action agitator ensures thorough cleaning by moving clothes in multiple directions, providing better agitation and fabric care. This technology not only ensures a deeper clean but also helps in preserving the integrity of fabrics over time.

Energy efficiency is another hallmark of the Kenmore 153 series. Many models are ENERGY STAR certified, which means they meet stringent energy efficiency guidelines set by the U.S. Environmental Protection Agency and the Department of Energy. This leads to significant cost savings over time, making them a smart choice for eco-conscious consumers looking to reduce their environmental footprint.

The Kenmore 153 series also emphasizes user-friendly features. With intuitive control panels and easy-to-read displays, these machines make laundry tasks simpler. Some models include a variety of customizable wash cycles, allowing users to select the optimal settings for different types of fabrics and soil levels. The quick wash and dryer cycles are particularly beneficial for those with busy lifestyles, reducing the time spent on laundry.

Noise reduction technology is another advantage. The Kenmore 153 series is designed with sound-dampening materials and features that minimize operational noise, making them ideal for homes where quiet is preferred, such as during nighttime laundry routines.

In terms of build quality, these models are constructed with durable materials aimed at longevity and reliability. Users can expect years of dependable service, with many designs offering warranties to back their durability claims.

In conclusion, the Kenmore 153 series, including models 153.335916, 153.335942, 153.335962, 153.335845, and 153.335862, encapsulates a blend of advanced laundry technologies, energy efficiency, user-friendly features, and robust build quality. These attributes make them a valuable addition to any household, simplifying the laundry process while delivering excellent results.