FREESTANDING WITH OPTIONAL PEDESTAL INSTALLATION

1. Place heater on backside and center the pedestal on the bottom. Mark the 4 pre-punched holes in the pedestal angle. Use the 4 self-tapping screws provided with the pedestal to drill the 4 marked spots. Secure the pedestal to the bottom of the unit.

NOTE: If the gas line is run through the floor, you may want to drill a hole in the bottom of the pedestal.

2.The pedestal must be secured to the floor. One option is to drill holes in the top side of the bottom of the pedestal. Use screws or “Ell” brackets to fasten pedestal to the floor.

IMPORTANT: THE 1127 FREESTANDING UNIT MUST BE INSTALLED ON A FLAT

FREESTANDING OPTIONAL WOODEN MANTEL INSTALLATION

Use the two (2) metal mounting Z-Brackets provided to secure the 1127 into the wooden mantel, wood screws provided to secure the brackets in place.

IMPORTANT! The Z-Brackets must be properly installed. Failure to install the Z-Brackets may cause property damage or personal injury.

Use the four (4) sheet metal screws provided to secure the mounting brackets to the rear of the stove. Insert the screws into the back of the unit.

With the brackets secured to the unit. From the rear slide the unit into the opening of the mantel, cen- tering from left to right.

With the four (4) wood screws provided secure the brackets to the rear of the mantel. See Figure 7, page 12.

NOTE: Connect gas line and check for leaks before placing the heater and mantel against the wall. See “Gas Connection” on page 17.

OPTION: Fasten the wooden mantel to the wall. Use “Ell” brackets at top or bottom corners.

11

Image 13
Contents MODEL 1127B VENT-FREEGAS HEATER NEW BUCK CORPORATIONManufacturer NEW BUCK CORPORATION P.O. Box 8000 Highway 226 South Spruce Pine, NCPage TABLE OF CONTENTS Page SAFETY INFORMATION WARNINGS Do not try to light any appliance 21. . ”WARNING Failure to keep the primary air openings of the burners clean may result in sooting and property damage.” PRODUCT IDENTIFICATION UNPACKING PRODUCT FEATURESSAFETY DEVICE PIEZO IGNITION SYSTEMNOTE FOR GARAGE INSTALLATION MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTIONFor convenience and efficiency, install heater 1.Wall Mounted INSTALLATION2.Freestanding heater with optional pedestal 3.Freestanding with optional wooden mantelCLEANING INFORMATION FREESTANDING OPTIONAL WOODEN MANTEL INSTALLATION FREESTANDING WITH OPTIONAL PEDESTAL INSTALLATIONOPTIONAL “L” BRACKETS 2 AND SCREWS 2 PRO DETERMINING FRESH-AIRFLOW FOR HEATER LOCATION PRODUCING ADEQUATE VENTILATIONVent-freeheater VENTILATION AIR FROM INSIDE BUILDING VENTILATION AIRVENTILATION AIR FROM OUTDOORS FLAME GAS CONNECTIONPropane Supply Tank CONNECTING TO A GAS SUPPLYExternal Regulator Vent Pointing Down Installation must include manual shutoff valve and plugged 1/2 NPT tap. Locate NPT tap within reach for test gauge hook-up.NPT tap must be upstream from unit GAS PRESSURE CHECK Logs are shipped secured in unit LOG PLACEMENT FORFront View of Logs LIGHTING INSTRUCTIONS MODULATING VALVEMAXITROL FOR YOUR SAFETY, READ BEFORE LIGHTINGOPERATING INSTRUCTIONS to IGNITE and LIGHTING INSTRUCTIONSfor “LOW” for “HIGH”IGNITER ELECTRODE THERMO-COUPLE TO TURN OFF GAS TO APPLIANCEO.D.S PILOT BURNER THERMOSTAT CONTROL OPERATION MANUAL LIGHTING PROCEDUREFLAME CHECK CORRECT FLAME PATTERN AT HIGH POSITION BURNER FLAME PATTERNFigure 1815 - Correct Burner Flame Pattern INCORRECT FLAME PATTERN AT HIGH POSITIONPOWER CORD WIRING DIAGRAMMOTOR JUMPERTHERMOSTATSERVICING REPAIR PARTSCLEANING IMPORTANT SAFEGUARDSTROUBLE-SHOOTING SOLUTION PROBLEMOBSERVED POSSIBLE1.Control knob is not fully pressed in Delayed ignition of burner 1. Heater produces a clinking MODEL 1127 - MODULATING VALVE TECHNICAL SERVICEPARTS LIST MOTOR, AND ALL REMOVABLE PARTS BLOWN UP VIEW OF HEATER, FANBURNER SYSTEM PARTS LISTBLOWN UP VIEW OF BURNER ASSEMBLY NEW BUCK CORPORATION LIMITED WARRANTY ON VENT-FREEGAS LOG HEATER