IGNITER ELECTRODE

IGNITER ELECTRODE

THERMO-COUPLEO.D.S PILOT BURNER

14.Close the access panel door.

15.“Turn on all electric power to the appliance.”

O.D.S PILOT BURNER

PILOT

TO TURN OFF GAS TO APPLIANCE

SHUTTING OFF UNIT:

1.Open access panel door, located in lower front center of base for access to control knobs.

2.Set thermostat (flame control) to lowest setting.

3.Turn control knob clockwise TO TURN OFF GAS TO APPLIANCE to the full “OFF” position.

4.“Turn off all electrical power to the appliance if service is to be performed.”

5.Close access panel door.

SHUTTING OFF BURNER ONLY (pilot stays lit)

1.Open access panel door, located in lower front center of base for access to control knobs.

2.Turn control knob clockwise Manual background to the “PILOT” position.

3.Close access panel door.

24

Image 26
Contents Manufacturer NEW BUCK CORPORATION P.O. Box NEW BUCK CORPORATIONMODEL 1127B VENT-FREEGAS HEATER 8000 Highway 226 South Spruce Pine, NCPage TABLE OF CONTENTS Page SAFETY INFORMATION WARNINGS Do not try to light any appliance 21. . ”WARNING Failure to keep the primary air openings of the burners clean may result in sooting and property damage.” PRODUCT IDENTIFICATION SAFETY DEVICE PRODUCT FEATURESUNPACKING PIEZO IGNITION SYSTEMFor convenience and efficiency, install heater MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTIONNOTE FOR GARAGE INSTALLATION 2.Freestanding heater with optional pedestal INSTALLATION1.Wall Mounted 3.Freestanding with optional wooden mantelCLEANING INFORMATION FREESTANDING WITH OPTIONAL PEDESTAL INSTALLATION FREESTANDING OPTIONAL WOODEN MANTEL INSTALLATIONOPTIONAL “L” BRACKETS 2 AND SCREWS 2 PRO PRODUCING ADEQUATE VENTILATION DETERMINING FRESH-AIRFLOW FOR HEATER LOCATIONVent-freeheater VENTILATION AIR VENTILATION AIR FROM INSIDE BUILDINGVENTILATION AIR FROM OUTDOORS GAS CONNECTION FLAMEExternal Regulator Vent Pointing Down CONNECTING TO A GAS SUPPLYPropane Supply Tank Installation must include manual shutoff valve and plugged 1/2 NPT tap. Locate NPT tap within reach for test gauge hook-up.NPT tap must be upstream from unit GAS PRESSURE CHECK Front View of Logs LOG PLACEMENT FORLogs are shipped secured in unit OPERATING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS MODULATING VALVEMAXITROL for “LOW” LIGHTING INSTRUCTIONSto IGNITE and for “HIGH”O.D.S PILOT BURNER TO TURN OFF GAS TO APPLIANCEIGNITER ELECTRODE THERMO-COUPLE MANUAL LIGHTING PROCEDURE THERMOSTAT CONTROL OPERATIONFLAME CHECK Figure 1815 - Correct Burner Flame Pattern BURNER FLAME PATTERNCORRECT FLAME PATTERN AT HIGH POSITION INCORRECT FLAME PATTERN AT HIGH POSITIONMOTOR WIRING DIAGRAMPOWER CORD JUMPERTHERMOSTATREPAIR PARTS SERVICINGIMPORTANT SAFEGUARDS CLEANINGTROUBLE-SHOOTING OBSERVED PROBLEMSOLUTION POSSIBLE1.Control knob is not fully pressed in Delayed ignition of burner 1. Heater produces a clinking TECHNICAL SERVICE MODEL 1127 - MODULATING VALVEPARTS LIST BLOWN UP VIEW OF HEATER, FAN MOTOR, AND ALL REMOVABLE PARTSPARTS LIST BURNER SYSTEMBLOWN UP VIEW OF BURNER ASSEMBLY LIMITED WARRANTY ON VENT-FREEGAS LOG HEATER NEW BUCK CORPORATION