New Buck Corporation FP-BR-10-ZC Installation After-Marketmobile Homes, Gas Connection, Flame

Page 15
INSTALLATION

INSTALLATION

AFTER-MARKET MOBILE HOMES

GAS CONNECTION

CHECK GAS TYPE: Use only the type of gas indicated on the valve rating plate. If the type of gas vlisted on the plate is not your type of gas supply, DO NOT INSTALL . Contact your dealer for proper model.

Always use an external regulator for all LP heaters to reduce the supply tank pressure to a maximum of 13” W.C. This in addition to the regulator furnished with the heater.

The normal gas connection is 3/8” N.P.T. made at the right rear side of the appliance.

NOTE: The connecting pipe must be internally tinned copper tubing for use with natural gas. Test for leaks using a solution of soap and water after completing the connection. DO NOT USE OPEN

FLAME.

INSTALLATION SUPPLIES

 

 

Before installing the heater, gather the following materials:

 

 

-

external regulator

-

ground joint union

 

(supplied by installer for propane)

-

sediment trap

- piping (check local codes)

-

tee joint

-

manual shutoff valve*

-

pipe wrench

-

test gauge connection*

- sealant (resistant to LP gas)

Page 13

Image 15
Contents P.O. Box 69 8000 Highway 226 South MODEL FP-BR-10-ZC VENT-FREEMarch Manufacturer NEW BUCK CORPORATIONPage TABLE OF CONTENTS Page Page Page Page DRAFTS INSTALLATIONCHOOSING THE LOCATION FOR YOUR FIREPLACE GAS LINES25 1/8” 24” 1 3/4” 25 1/8” 11 5/8”1/8” 1/8”17-3/4 INSTALLING THE FIREBOXFIREPLACE CLEARANCES Install the Firebox7 MIN FINISHING YOUR FIREPLACECLEARANCES SIDE WALLif mantel is 12 wide or less MANTEL PROFILES FOR ZERO CLEARANCE CABINETMUST BE FOLLOWED of Unit if mantel is 10 wide or moreNOTE See page 18 for “Gas Pressure Check” REAR 1/2 WOOD SCREWSTOP MANTEL MANTEL BASEINSTALLATION AFTER-MARKETMOBILE HOMES GAS CONNECTIONFLAME PRODUCING ADEQUATE VENTILATION DETERMINING FRESH-AIRFLOW FOR HEATER LOCATION VENTILATION AIR FROM INSIDE BUILDING VENTILATION AIRTo Attic VENTILATION AIR FROM OUTDOORSVentilated Attic Outlet Air Outlet AirGAS PRESSURE CHECK Page LOG PLACEMENTLogs are shipped secured in unit Front View of LogsOPERATING INSTRUCTIONS Page Page Page FLAME NATURAL PROPANE FLAME CHECKJUMPERTHERMOSTAT WIRING DIAGRAMPOWER CORD MOTORNOTE #PESBRO84 Blower Motor Rating 120 volts/60HZ/0.54 Amps. 1 P.HPage CLEANING IMPORTANT SAFEGUARDSOBSERVED TROUBLESHOOTINGPROBLEM SOLUTIONDepleted gas supply 6. Burner backfiring during WARNING above Important aboveWARNING above WARNING aboveSERVICING REPAIR PARTSMaxitrol Valve PARTS LISTPage BLOWN UP VIEW OF BURNER ASSEMBLYNEW BUCK CORPORATION LIMITED WARRANTY MODEL FP-BR10-ZCPage