New Buck Corporation MODEL FP-327-ZC manual Observed Problem

Page 37
OBSERVED

IMPORTANT: Operating heater where impurities in the air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc. create fumes. These fumes may mix with combustion air and create odor.

OBSERVED

PROBLEM

Heater produces a clinking/ticking noise just after burner is lit or shut off

Heater produces unwanted odors

POSSIBLE

CAUSE

1.Metal expands while heating or contracts while cooling.

1.Heater burning vapors from paint, hairspray, glues, etc. (See Important above)

2.Low fuel supply

3.Gas leak (See WARNING above)

SOLUTION

1.This is common with most heaters. If noise is excessive, contact a qualified service person.

1.Ventilate room. Stop using odor causing products while heater is running.

2.Refill supply tank

3.Locate and control all leaks. See Checking Gas Connections.

Heater shuts off in use (ODS operates)

1.Not enough fresh air is available

2.Low line pressure

3.ODS/Pilot is partially clogged

1 . Open window/door for ventilation

2.Contact local propane company

3.Clean ODS/Pilot

Gas odor even when

1.

Gas leak (See WARNING,

control knob is in “OFF”

 

above).

position

2.

Control valve defect

Gas odor during com-

1.

Foreign matter between

bustion

2.

control valve and burner

 

Gas leak (See WARNING

above)

1.Locate and correct all leaks (see Checking Gas Connections)

2.Replace control valve

1.Remove foreign matter from gas tubing

2.Locate and correct all leaks (see Checking Gas Connections)

Page 35

Image 37
Contents NEW BUCK CORPORATION MODEL FP-327-ZCManufacturer NEW BUCK CORPORATION P.O. Box 8000 Highway 226 South Spruce Pine, NCPage TABLE OF CONTENTS Page SECTION I SAFETY INFORMATION WARNINGS Page Page CHOOSING THE LOCATION FOR YOUR FIREPLACE SECTION ZERO CLEARANCE INSTALLATIONGAS LINE DRAFTS3 1/4 Fireplace and Framing Dimensions inches7 1/2 PageFIREPLACE CLEARANCES INSTALLING THE FIREBOXInstall the Firebox Framing the FireboxCLEARANCES FINISHING YOUR FIREPLACEMUST BE FOLLOWED MANTEL PROFILES FOR ZERO CLEARANCE CABINETMANTEL 3/4 FLAT SURFACE MANTEL 3/4 FLAT SURFACEWITH OPTIONAL WOODEN MANTEL INSTALLATION OF MODEL FP - 327- ZCTOP MANTEL 1/2 WOOD SCREWSREAR OF HEATER MANTEL BASESECTION AFTER MARKET MOBILE HOME INSTALLATION DETERMINING FRESH-AIRFLOW FOR HEATER LOCATION PRODUCING ADEQUATE VENTILATIONVent-freeheater VENTILATION AIR FROM INSIDE BUILDING VENTILATION AIRVENTILATION AIR FROM OUTDOORS FLAME GAS CONNECTIONSEE DIAGRAM ON PAGE PLACEMENT OF LOGSGAS PRESSURE CHECK 3 1 2 Figure PLACEMENT OF LOGSPage LIGHTING INSTRUCTIONS MILLIVOLT VALVE ITT FOR YOUR SAFETY, READ BEFORE LIGHTINGWHAT TO DO IF YOU SMELL GAS BEFORE INSTALLING THERMOSTAT ROCKER SWITCHREMOVE METAL CONNECTOR PagePILOT BURNER IGNITOR ELECTRODETHERMO--COUPLEPILE PageTHERMOSTAT CONTROL OPERATION MANUAL LIGHTING PROCEDUREFOR YOUR SAFETY, READ BEFORE LIGHTING LIGHTING INSTRUCTIONS MODULATING VALVEMAXITROLto IGNITE and LIGHTING INSTRUCTIONSfor “LOW” for “HIGH”O.D.S PILOT BURNER IGNITER ELECTRODE THERMO-COUPLETO TURN OFF GAS TO APPLIANCE THERMOSTAT CONTROL OPERATION MANUAL LIGHTING PROCEDURENATURAL PILOT FLAME CHECKBURNER PROPANE PILOTWIRING DIAGRAM Rating 120 volts/60HZ/0.54 Amps NOTE #PESBRO84 Blower Model FP-327-ZCPage CLEANING IMPORTANT SAFEGUARDSTROUBLE SHOOTING Air in gas lines when OBSERVED PROBLEM OBSERVED SERVICING REPAIR PARTSMaxitrol Valve PARTS LISTPage BLOWN UP VIEW OF BURNER ASSEMBLYPARTS LIST ITT ValvePage BLOWN UP VIEW OF BURNER ASSEMBLYPage Page